1.
IEEE Trans Biomed Circuits Syst ; 17(4): 808-817, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37318976

RESUMO

Sweat secreted by the human eccrine sweat glands can provide valuable biomarker information during exercise. Real-time non-invasive biomarker recordings are therefore useful for evaluating the physiological conditions of an athlete such as their hydration status during endurance exercise. This work describes a wearable sweat biomonitoring patch incorporating printed electrochemical sensors into a plastic microfluidic sweat collector and data analysis that shows the real-time recorded sweat biomarkers can be used to predict a physiological biomarker. The system was placed on subjects carrying out an hour-long exercise session and results were compared to a wearable system using potentiometric robust silicon-based sensors and to commercially available HORIBA-LAQUAtwin devices. Both prototypes were applied to the real-time monitoring of sweat during cycling sessions and showed stable readings for around an hour. Analysis of the sweat biomarkers collected from the printed patch prototype shows that their real-time measurements correlate well (correlation coefficient ≥ 0.65) with other physiological biomarkers such as heart rate and regional sweat rate collected in the same session. We show for the first time, that the real-time sweat sodium and potassium concentration biomarker measurements from the printed sensors can be used to predict the core body temperature with root mean square error (RMSE) of 0.02 °C which is 71% lower compared to the use of only the physiological biomarkers. These results show that these wearable patch technologies are promising for real-time portable sweat monitoring analytical platforms, especially for athletes performing endurance exercise.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Suor/química , Temperatura Corporal , Eletrólitos , Biomarcadores/análise
2.
Biosens Bioelectron ; 234: 115342, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37141829

RESUMO

The early detection of very low bacterial concentrations is key to minimize the healthcare and safety issues associated with microbial infections, food poisoning or water pollution. In amperometric integrated circuits for electrochemical sensors, flicker noise is still the main bottleneck to achieve ultrasensitive detection with small footprint, cost-effective and ultra-low power instrumentation. Current strategies rely on autozeroing or chopper stabilization causing negative impacts on chip size and power consumption. This work presents a 27-µW potentiostatic-amperometric Delta-Sigma modulator able to cancel its own flicker noise and provide a 4-fold improvement in the limit of detection. The 2.3-mm2 all-in-one CMOS integrated circuit is glued to an inkjet-printed electrochemical sensor. Measurements show that the limit of detection is 15 pArms, the extended dynamic range reaches 110 dB and linearity is R2 = 0.998. The disposable device is able to detect, in less than 1h, live bacterial concentrations as low as 102 CFU/mL from a 50-µL droplet sample, which is equivalent to 5 microorganisms.


Assuntos
Bactérias , Técnicas Biossensoriais , Técnicas Biossensoriais/instrumentação , Bactérias/isolamento & purificação
3.
IEEE Trans Biomed Circuits Syst ; 15(5): 860-876, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34543202

RESUMO

This paper presents a 1024-channel neural read-out integrated circuit (ROIC) for solution-gated GFET sensing probes in massive µECoG brain mapping. The proposed time-domain multiplexing of GFET-only arrays enables low-cost and scalable hybrid headstages. Low-power CMOS circuits are presented for the GFET analog frontend, including a CDS mechanism to improve preamplifier noise figures and 10-bit 10-kS/s A/D conversion. The 1024-channel ROIC has been fabricated in a standard 1.8-V 0.18- µm CMOS technology with 0.012 mm 2 and 36 µ W per channel. An automated methodology for the in-situ calibration of each GFET sensor is also proposed. Experimental ROIC tests are reported using a custom FPGA-based µECoG headstage with 16×32 and 32×32 GFET probes in saline solution and agar substrate. Compared to state-of-art neural ROICs, this work achieves the largest scalability in hybrid platforms and it allows the recording of infra-slow neural signals.


Assuntos
Mapeamento Encefálico , Calibragem
4.
Sensors (Basel) ; 17(6)2017 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-28574466

RESUMO

Infrared imaging technology, used both to study deep-space bodies' radiation and environmental changes on Earth, experienced constant improvements in the last few years, pushing data converter designers to face new challenges in terms of speed, power consumption and robustness against extremely harsh operating conditions. This paper presents a 96.6-dB-SNDR (Signal-to-Noise-plus-Distortion Ratio) 50-kHz-bandwidth fourth-order single-bit switched-capacitor delta-sigma modulator for ADC operating at 1.8 V and consuming 7.9 mW fit for space instrumentation. The circuit features novel Class-AB single-stage switched variable-mirror amplifiers (SVMAs) enabling low-power operation, as well as low sensitivity to both process and temperature deviations for the whole modulator. The physical implementation resulted in a 1.8-mm2 chip integrated in a standard 0.18-µm 1-poly-6-metal (1P6M) CMOS technology, and it reaches a 164.6-dB Schreier figure of merit from experimental SNDR measurements without making use of any clock bootstrapping,analogcalibration,nordigitalcompensationtechnique. Whencoupledtoa2048×2048 IR imager, the current design allows more than 50 frames per minute with a resolution of 16 effective number of bits (ENOB) while consuming less than 300 mW.