Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Orthop ; 13(4): 301-5, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27408509

RESUMO

BACKGROUND: This retrospective study aims to present and evaluate the long follow-up results of posterior instrumentation without fusion in patients with traumatic thoracic and lumbar fractures. METHODS: 45 patients were operated. The mean follow-up period was 147.6 months. Sagittal plane kyphosis (SPK) and anterior wedge angle (AWA) were evaluated in preoperative and follow-up. RESULTS: SPK and AWA improved significantly in the early postoperative. However, the correction was lost in the 10-year follow-up. The loss of correction was statistically significant in SPK and AWA. CONCLUSION: Posterior instrumentation without fusion is still among the most useful in treatment of traumatic thoracolumbar fractures.

3.
Indian J Orthop ; 50(1): 94-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26955183

RESUMO

BACKGROUND: Proximal locking screw deformation and screw fracture is a frequently seen problem for femur interlocking nailing that affects fracture healing. We realized that there is lack of literature for the right level for the proximal locking screw. We investigated the difference of locking screw bending resistance between the application of screws on different proximal femoral levels. MATERIALS AND METHODS: We used a total of 80 proximal locking screws for eight groups, 10 screws for each group. Three-point bending tests were performed on four types of screws in two different trochanteric levels (the lesser trochanter and 20 mm proximal). We determined the yield points at three-point bending tests that a permanent deformation started in the locking screws using an axial compression testing machine. RESULTS: The mean yield point value of 5 mm threaded locking screws applied 20 mm proximal of lesser trochanter was 1022 ± 49 (range 986-1057) (mean ± standard deviation, 95% confidence interval). On the other hand, the mean yield point value of the same type of locking screws applied on the lesser trochanteric level was 2089 ± 249 (range 1911-2268). Which means 103% increase of screw resistance between two levels (P = 0.000). In all screw groups, on the lesser trochanter line we determined 98-174% higher than the yield point values of the same type of locking screws in comparison with 20 mm proximal to the lesser trochanter (P = 0.000). CONCLUSION: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures.

4.
Case Rep Orthop ; 2016: 3145343, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26977327

RESUMO

A case of a bilateral simultaneous traumatic obturator dislocation of both hip joints in an 18-year-old young man following a traffic accident is presented. We reduced the dislocated femoral heads immediately under general anesthesia followed by passive and active exercises and early full-weight bearing mobilization. After 5 years, the result was excellent.

5.
Strategies Trauma Limb Reconstr ; 11(1): 25-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26837377

RESUMO

Nailing of tibial shaft fractures is considered the gold standard surgical method by many surgeons. The aim of this retrospective study was to investigate and compare the clinical outcome of tibial shaft fractures treated with intramedullary nails compressed by proximal tube and conventional intramedullary interlocking nails. Fifty-seven patients with tibial shaft fractures, treated with intramedullary nails compressed by proximal tube (n = 32) and the conventional interlocking nails (n = 25), were reviewed. All fractures except for one were united without any additional surgical intervention in the proximal compression tube nail group, whereas in the conventional interlocking nail group, six patients needed dynamization surgery (p = 0.005) and three cases of nonunion were recorded. In the proximal compression tube nail group, faster union occurred in 20 ± 2 (16-24) weeks (mean ± SD; range) without failure of locking screws and proximal nail migration, whereas in the conventional interlocking nail group, union occurred in 22 ± 2.5 (17-27) weeks (p = 0.001) with two failures of locking screws and two proximal nail migration. The proximal compression tube nail system is safer than the conventional nailing methods for the treatment for transverse and oblique tibial shaft fractures with a less rate of nonunion, proximal locking screw failure and proximal nail migration.

6.
Acta Orthop Traumatol Turc ; 50(1): 89-96, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26854055

RESUMO

OBJECTIVE: One of the problems for interlocking nailing of the femur is interfragment rotation motion, affecting fracture healing. The nails with single distal locking screw are advantageous for decreasing operation time and radiation exposure. We investigated which single distal screw nail is the best for interfragment rotational stability. METHODS: We used a total of 30 composite femurs, ten for each group. We determined interfragment rotational displacement of composite femurs with three types of single distal screw nails (10 interlocking nails, 10 compression nails and 10 Mehmet anti-rotation nails compressed by tube) at 6-Nm external- 6 Nm internal and 10 Nm extern- 6 Nm internal torques, which imitating respectively the level walking and descending stairs, using an axial distraction testing machine and a custom designed rotation apparatus. RESULTS: Between 10 Nm external and 6 Nm internal torques with single distal locking screw, the interfragment rotational displacement in the Mehmet nail compressed by the 8 Nm torque wrench was mean 1.14 mm and 540% less than mean 7.31 mm in interlocking nails and 400% less than 5.72 mm in compression nails compressed by the 2.5 Nm torque wrench. CONCLUSION: The single distal screw Mehmet nail is superior than other single (or even some double) distal screw nails for maximum rotational stability, with no interfragment distraction gap, no superior nail migration, decreased operation time, and less radiation exposure in axially stable transverse and short oblique femur fractures in daily activities like stair descending or level walking.

7.
Acta Orthop Traumatol Turc ; 49(5): 552-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26422352

RESUMO

OBJECTIVE: A frequent problem for interlocking nailing that affects the treatment of the fracture is locking screw deformation. The aim of this study is to determine whether bending resistance is different between high, low, and unthreaded locking screws of interlocking femoral nails. METHODS: Ninety screws were used in this experimental study, with 10 screws used in each of 9 groups. Three-point bending tests were performed on 6 groups of 5 mm screws (titanium, stainless steel, crossed with unthreaded, low threaded, and high threaded) and the same 3 thread types of 5.5 mm stainless steel screws in a 30-mm inner diameter steel tube, imitating the level of the lesser trochanter. An axial compressor was used to determine the yield points for permanent deformation in the locking screws by way of 3-point bending tests. RESULTS: The mean yield point value of the 3-point bending tests of 5-mm low threaded stainless steel locking screws was 2071 N, 53% less than that of unthreaded screws (3169 N). The mean yield point value of 5-mm high threaded stainless steel locking screws was 556 N, 272% less than that of low threaded screws (2071 N). CONCLUSION: To avoid locking screw deformation, high threaded screws must not be used as locking screws. In cases of unreliable patients, 5-mm low threaded screws should not be used in the nailing of comminuted or oblique femur shaft fractures. All 5-mm unthreaded screws and 5.5-mm low threaded stainless steel screws can be used safely in full weight-bearing conditions of unreliable patients.


Assuntos
Parafusos Ósseos , Fixação Intramedular de Fraturas/instrumentação , Teste de Materiais/métodos , Fenômenos Biomecânicos , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Resistência à Tração , Suporte de Carga
8.
Eklem Hastalik Cerrahisi ; 26(3): 131-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26514216

RESUMO

OBJECTIVES: This study aims to investigate which intramedullary nail is biomechanically better for establishing interfragmentary rotational stability. MATERIALS AND METHODS: Thirty composite femurs were utilized in this study. We analyzed interfragmentary rotational arc displacements between 10 Nm external-6 Nm internal torques and 6 Nm external-6 Nm internal torques which imitate rotation torques while walking on a flat surface and descending stairs by administering 10 interlocking nails, 10 compression nails, and 10 Mehmet anti-rotation nails with tube compression. RESULTS: Maximum interfragmentary rotation arc displacement between 10 Nm external rotation and 6 Nm internal rotation torques was mean 1.64 mm in the Mehmet nail compressed by 7 Nm torque wrench. This value was lower by 309% (6.72 mm) from interlocking nail (p=0.000), 201% (5.42 mm) from compression nail compressed by 2.5 Nm torque wrench (p=0.000), and 26% (1.92 mm) from compression nail compressed by 7 Nm torque wrench (p>0.05). CONCLUSION: In axially stable transvers and short oblique femur fractures, Mehmet nail is superior to other intramedullary nails with limited movement between locking screw and hole, more interfragmentary compression without locking screw deformation, and no proximal nail migration.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Complicações Pós-Operatórias/prevenção & controle , Rotação , Fenômenos Biomecânicos , Pinos Ortopédicos/efeitos adversos , Pinos Ortopédicos/classificação , Pinos Ortopédicos/normas , Parafusos Ósseos , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Humanos , Torque , Anormalidade Torcional/etiologia , Anormalidade Torcional/prevenção & controle
9.
Eklem Hastalik Cerrahisi ; 26(3): 145-50, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26514218

RESUMO

OBJECTIVES: This study aims to investigate whether there is any significant difference in bending resistance between titanium and stainless steel locking screws of femur nails and to review deformation of locking screws which is a common problem in interlocking nailing. MATERIALS AND METHODS: In this study, a total of 60 pieces of 5 mm major diameter titanium and stainless steel locking screws were used as six groups in three different thread depth structures (high threaded, low threaded, and unthreaded). Three-point bending tests were conducted on steel screws placed inside stainless steel tube with 30 mm inner diameter, which imitated the level of lesser trochanter. We used an axial compression testing machine in order to determine the yield points that permanent deformation occurred in the locking screws. RESULTS: For low threaded locking screws, which are the most frequently used thread type for locking screws, the mean bending yield points were 1413 N on the titanium screws and this level was below 1922 N (2.8 BW) of level walking loading on femur for 70 kg person. On low threaded stainless screws, bending resistance was 2071 N, which was above the value of 1922 N. For high threaded locking screws, the mean bending yield points were 874 N on the titanium screws and 556 N on stainless screws. CONCLUSION: In comminuted femur shaft fractures (in full load bearing conditions), using stainless steel locking screws is better instead of titanium screws to avoid locking screw deformation since low threaded stainless steel screws were 46.5% more resistant to bending deformation than titanium ones. Stainless steel or titanium high threaded locking screws may only be carefully used in non-comminuted fractures.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Aço Inoxidável/farmacologia , Titânio/farmacologia , Fenômenos Biomecânicos , Pinos Ortopédicos/classificação , Pinos Ortopédicos/normas , Fêmur/lesões , Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Humanos
10.
Acta Orthop Belg ; 81(2): 245-50, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26280963

RESUMO

The aim is to present our new method of compression, a compression tube instead of conventional compression screw and to investigate the difference of proximal locking screw bending resistance between compression screw application (6 mm wide contact) and compression tube (two contact points with 13 mm gap) application. We formed six groups each consisting of 10 proximal locking screws. On metal cylinder representing lesser trochanter level, we performed 3-point bending tests with compression screw and with compression tube. We determined the yield points of the screws in 3-point bending tests using an axial compression testing machine. We determined the yield point of 5 mm screws as 1963±53 N (mean±SD) with compression screw, and as 2929±140 N with compression tubes. We found 51% more locking screw bending resistance with compression tube than with compression screw (p=0,000). Therefore compression tubes instead of compression screw must be preferred at femur compression nails.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Teste de Materiais/métodos , Fenômenos Biomecânicos , Placas Ósseas , Seguimentos , Humanos , Estudos Prospectivos , Desenho de Prótese
12.
Agri ; 21(3): 121-5, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19780003

RESUMO

Spondylodiscitis is a serious and important clinical problem that can occur after iatrogenic interventions and should be kept in mind. Spondylodiscitis after transrectal ultrasonography (TRUS)-guided prostate biopsy is an extremely rare complication. A 70-year-old patient who presented with severe back pain, intermittent high fever, loss of appetite, and fatigue following TRUS-guided prostate biopsy was diagnosed with thoracic spondylodiscitis (T6-7) after clinical, laboratory and radiological assessments and he was treated surgically. We present this case to remind medical professionals to keep spondylodiscitis in mind in the presence of sudden onset back and low-back pain, since TRUS-guided prostate biopsy is a frequently used procedure.


Assuntos
Dor nas Costas/etiologia , Biópsia por Agulha/efeitos adversos , Discite/etiologia , Próstata/patologia , Vértebras Torácicas , Idoso , Dor nas Costas/diagnóstico , Discite/diagnóstico , Febre de Causa Desconhecida/etiologia , Humanos , Doença Iatrogênica , Masculino , Próstata/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...