Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 57(22): 7303-15, 2012 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-23079604

RESUMO

The purpose of this study was the mathematical analysis of IMRT with many non-coplanar fields for planning target volumes (PTV) surrounding nearly spherical organs at risk (OAR). Our approach is partially analogous to the well known inverse planning for a cylindrically symmetric (CS) case (Brahme et al 1982 Phys. Med. Biol. 27 1221-9) and leads to a spherically symmetric (SS) solution. For the planning study we approximated isotropic 4 Pi irradiation by a quasi-isotropic non-coplanar IMRT technique with 16 fields which we compared to a coplanar IMRT technique with 15 equidistant fields. A virtual spherical phantom contained a spherical central organ at risk which was surrounded by a PTV shaped like a spherical shell with a gap towards the spherical OAR. We compared three types of plans: (1) non-segmented inversely planned fluence distributions prior to sequencing, (2) plans obtained by direct machine parameter optimization (DMPO) with up to 120 segments (good approximation of non-segmented fluence) and (3) more practical DMPO plans with up to 64 segments. In this study we sought an analytical SS solution for the non-segmented fluence distribution in 4 Pi-geometry. For the CS case Brahme et al found that a special narrow fluence peak ('Brahme peak') has to be applied to improve dose uniformity in PTV areas adjacent to the OAR. We showed that in the SS case the peak was steeper but the area under the peak was smaller. The relevance of the peak decreased for increasing gap between the OAR and the PTV. The plan quality of the non-segmented SS plans was higher albeit the fluence distributions were less uniform. The plan quality of the segmented plans degraded if the allowed number of segments was reduced; the degradation was quicker for the SS beam arrangement than for the CS beam arrangement. For 64 segments, the SS plans delivered less uniform and more conformal dose distributions than the CS plans, ensuring better sparing of the healthy tissue. Also, the SS plans always needed less monitor units than the CS plans. In conclusion, due to substructures or steeper fluence gradients, the improved potential of quasi-isotropic SS-plan quality can only be exploited, if many segments are allowed. SS plans seem to spare normal tissue better. Further analysis of non-coplanar beam arrangements with less degree of symmetry is planned, followed by a study on non-coplanar intensity modulated arc techniques.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica
2.
Radiat Oncol ; 7: 81, 2012 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-22682767

RESUMO

BACKGROUND: To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. MATERIALS AND METHODS: Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours served as reference for all IG techniques. Three IG techniques were performed independently by three radiation oncologists (ROs) and three radiotherapy technicians (RTTs). Image-guidance using respiration correlated 4D-CBCT (IG-4D) with automatic registration of the planning 4D-CT and the verification 4D-CBCT was considered gold-standard. Results were compared with two IG techniques using 3D-CBCT: 1) manual registration of the planning internal target volume (ITV) contour and the motion blurred tumor in the 3D-CBCT (IG-ITV); 2) automatic registration of the planning reference CT image and the verification 3D-CBCT (IG-3D). Image quality of 3D-CBCT and 4D-CBCT images was scored on a scale of 1-3, with 1 being best and 3 being worst quality for visual verification of the IGRT results. RESULTS: Image quality was scored significantly worse for 3D-CBCT compared to 4D-CBCT: the worst score of 3 was given in 19 % and 7.1 % observations, respectively. Significant differences in target localization were observed between 4D-CBCT and 3D-CBCT based IG: compared to the reference of IG-4D, tumor positions differed by 1.9 mm ± 0.9 mm (3D vector) on average using IG-ITV and by 3.6 mm ± 3.2 mm using IG-3D; results of IG-ITV were significantly closer to the reference IG-4D compared to IG-3D. Differences between the 4D-CBCT and 3D-CBCT techniques increased significantly with larger motion amplitude of the tumor; analogously, differences increased with worse 3D-CBCT image quality scores. Inter-observer variability was largest in SI direction and was significantly larger in IG using 3D-CBCT compared to 4D-CBCT: 0.6 mm versus 1.5 mm (one standard deviation). Inter-observer variability was not different between the three ROs compared to the three RTTs. CONCLUSIONS: Respiration correlated 4D-CBCT improves the accuracy of image-guidance by more precise target localization in the presence of breathing induced target motion and by reduced inter-observer variability.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares/diagnóstico por imagem , Variações Dependentes do Observador , Radiocirurgia , Cirurgia Assistida por Computador , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos