Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1258-1261, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086560

RESUMO

We fabricated a wearable sensor that can be attached to the skin surface and continuously measure core body temperature (CBT) wirelessly over a long period. CBT is calculated from skin-surface temperature and heat flux passing through the sensor. Since heat flux is lost to the surroundings of the probe, the slightest change in convection in daily life will degrade the measurement accuracy of the sensor. Accordingly, we previously proposed a heat-flux-path control structure to reduce the absolute amount of heat-flux loss. To make wearable sensors for long-term human trials, we proposed an integrated design in which a sensor probe, a circuit board, and a battery are stacked. We optimized the proposed design by computer simulation and evaluated the fabricated sensor by a phantom experiment in which the convectional state was changed. The evaluation results demonstrate that the sensor has limits of agreement (LOA) of [-0.13; 0.03]°C under 1-m/s-wind convection. Moreover, a preliminary human trial conducted under daily-life conditions (including convectional changes) demonstrated that the sensor has LOA of [-0.18; 0.22]°C. These results demonstrate that the fabricated sensor is suitable for CBT measurement.


Assuntos
Temperatura Corporal , Termômetros , Simulação por Computador , Humanos , Temperatura Cutânea , Temperatura
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4377-4380, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018965

RESUMO

We describe the design of a thermometer that can be worn during everyday activities for monitoring core body temperature (CBT) at the skin surface. This sensor estimates the CBT by measuring the heat flux from the body core based on a thermal conductive model. The heat flux is usually affected by the ambient convective conditions (e.g. air conditioner or posture), which in turn affects the model's accuracy. Thus, we analytically investigated heat conduction and designed a sensor interface that would be robust to convection changes. We performed an in vitro experiment and a preliminary in vivo experiment. The accuracy of CBT in an in vitro experiments was 0.1°C for convective values ranging from 0 to 1.2 m/s. The wearable thermometer has high potential as non-invasive CBT monitor.


Assuntos
Termômetros , Dispositivos Eletrônicos Vestíveis , Temperatura Corporal , Temperatura Alta , Monitorização Fisiológica
3.
J Environ Monit ; 1(2): 135-42, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11529091

RESUMO

Petroleum hydrocarbon vapors at low ppb levels can be detected using a thickness shear mode resonator (TSMR) coated with a chemical-sensing overlayer, prepared by radiofrequency sputtering of porous sintered-polyethylene (PS-PE). The sensing capabilities of PS-PE sensors were profoundly affected by the sputtering methods; they were enhanced by the photo-excitation effect, and were reduced by carbonization and water treatment. The photo-assisted PS-PE sensor was extremely sensitive and could detect linear hydrocarbon (> C12) vapors below the ppb level. The time constant of the sorption curve, however, was large, indicating a slow sensing speed. Toward creating instrumentation for a smart environmental monitoring system, the TSMR sensors were arrayed on a circuit board equipped with a serial interface and signal processing chips of the oscillation drive and frequency counter. Co-sorption with water vapor at a relative humidity of about 10% has almost no effect on the sensing ability of PS-PE sensors for 1,2,4-trimethylbenzene. Conversely, it enhances the sensitivity of the TSMR sensor coated with a D-phenylalanine film. Upward shifts in the baseline are evident with elapsed time. However, a rigorous ten-cycle iteration test for 100 ppm toluene vapor demonstrated good reproducibility of the sensor's signals.


Assuntos
Poluição do Ar/análise , Monitoramento Ambiental/instrumentação , Hidrocarbonetos/análise , Monitoramento Ambiental/métodos , Petróleo/análise , Quartzo , Radioquímica , Sensibilidade e Especificidade , Volatilização
4.
Talanta ; 46(6): 1293-7, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18967256

RESUMO

The concentration of potassium was determined by a combination of flow injection analysis (FIA) with an all-solid-state potassium sensor detection. The all-solid-state potassium-selective electrode possessing long-term potential stability was fabricated by coating an electroactive polypyrrole/poly(4-styrenesulfonate) film electrode with a plasticized poly(vinyl chloride) membrane containing valinomycin. The simple FIA system developed in this laboratory demonstrated sensitivity identical to that in the batch system and achieved considerably rapid assay (150 samples h(-1)). Analyses of soy sauce and control serum samples by this FIA system yielded results in good agreement with those obtained by conventional measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...