Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cent South Univ ; 29(7): 2415-2430, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36034192

RESUMO

Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission. Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate, which may lead to high energy consumption. The Wells-Riley (WR) model is widely used to predict infection risk and control the ventilation rate. However, few studies compared the non-steady-state (NSS) and steady-state (SS) WR models that are used for ventilation control. To fill in this research gap, this study investigates the effects of the mechanical ventilation control strategies based on NSS/SS WR models on the required ventilation rates to prevent airborne transmission and related energy consumption. The modified NSS/SS WR models were proposed by considering many parameters that were ignored before, such as the initial quantum concentration. Based on the NSS/SS WR models, two new ventilation control strategies were proposed. A real building in Canada is used as the case study. The results indicate that under a high initial quantum concentration (e.g., 0.3 q/m3) and no protective measures, SS WR control underestimates the required ventilation rate. The ventilation energy consumption of NSS control is up to 2.5 times as high as that of the SS control.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...