Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35301524

RESUMO

The surgical repair of type A aortic dissection often involves prosthetic proximal aortic and arch reconstruction. Hypothermic circulatory arrest is typically used in these complex surgeries given the required prolonged ischaemia and the associated morbidity and mortality. A novel vascular anastomoses device (Device) has been developed to rapidly connect a native vessel to a polyester graft. This study describes deployment of the Device in the ovine model (n = 3; 6 carotid arteries). Anastamoses were created rapidly, and brain ischaemia time was limited to 6 min in all but one vessel. All vessels remained fully patent with normal blood flow and thrombus-free transitions through 6 months. Results thus suggest that this Device has the potential to reduce anastomosis time versus conventional suturing techniques and thereby reduce hypothermic circulatory arrest time.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Isquemia Encefálica , Anastomose Cirúrgica , Dissecção Aórtica/cirurgia , Animais , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Humanos , Ovinos , Resultado do Tratamento
3.
Surg Endosc ; 25(5): 1402-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20976498

RESUMO

BACKGROUND: The current indications for using a robotic technique in bariatric surgery remain unclear. The objective of this study was to quantify the safety and potential benefits of this novel technology as compared to the conventional laparoscopic approach. METHODS: A retrospective database of patients who underwent laparoscopic adjustable gastric banding (LAGB) between December 2006 and June 2009 was examined. During this period 407 consecutive patients underwent LAGB: 287 robotically and 120 conventionally. Patient demographics, operative complications, operating times, and clinical outcomes were examined. RESULTS: The patients in the robotic and conventional cohorts did not vary significantly in demographics. The prevalence of preoperative comorbidities was similar between the two groups. The rates of intraoperative and postoperative complications did not differ significantly between the two approaches. The length of postoperative hospital stay (1.3±0.6 days for both approaches) and the operating time (91.5±21.1 vs. 92.1±30.9 min for robotic and conventional, respectively) did not differ significantly between the two approaches. However, for patients with a preoperative BMI≥50 kg/m2 (n=89, 64 robotic and 25 conventional), the operating time was significantly shorter using the robotic approach (91.3±19.7 min for robotic vs. 101.3±23.7 min for conventional, p=0.04). CONCLUSIONS: In this series, robotic and conventional approaches were similar in complication rates, operating time, and length of postoperative hospital stay. However, for patients with a preoperative BMI≥50 kg/m2, the operating time is significantly shorter using the robotic approach despite the adoption of this new technique. These data suggest that the robotic approach is at least as safe as the conventional laparoscopic approach in LAGB, and that the robotic approach should be considered for gastric banding candidates with BMI≥50 kg/m2.


Assuntos
Gastroplastia , Laparoscopia , Obesidade Mórbida/cirurgia , Robótica , Adulto , Idoso , Cirurgia Bariátrica , Feminino , Gastroplastia/métodos , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Redução de Peso , Adulto Jovem
5.
Surg Obes Relat Dis ; 4(3): 416-22, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18226977

RESUMO

BACKGROUND: Few studies have been designed to assess the performance of surgical staplers. In this study, we analyzed the effect of staple height, buttressing, and overlapping of staple lines on staple line failure. METHODS: Staple lines created on fresh porcine small bowel segments ex vivo were tested for leak pressure by insufflating air into the bowel under water and recording pressure at failure. Three separate experiments were done and included staple height (white, 2.5 mm, n = 16; blue, 3.5 mm, n = 16; green, 4.1 mm, n = 16; one half of them buttressed); the absence (n = 12) or presence (n = 12) of an overlap in 3.5-mm staple lines; and the absence (n = 14) or presence (n = 11) of buttresses in 3.5-mm overlapping staple lines. Data are reported in median values and ranges; nonparametric tests were used for data analysis. RESULTS: In the porcine small bowel, leak pressure was related to staple height; green loads had the worst profile (35 mm Hg, range 19-105) compared with the blue (79 mm Hg, range 9-177), and white (108 mm Hg, range 28-280) loads (P = .006). Buttressing uniformly improved leak pressure for all staple loads (P <.0001). No significant difference was found between lines with overlapping (59 mm Hg, range 32-121) and those without (42 mm Hg, range 22-75; P = .162). Buttressing also improved the leak pressure of overlapping staple lines from 65 mm Hg (range 47-121) to 93 mm Hg (range 75-187; P = .0014). CONCLUSION: Great variability was found in the leak pressures among the different applications of the same stapler. Staple height is an important determinant of leak pressure. The presence of an overlap did not affect leak pressure; in fact, a trend toward improvement was seen with overlapping staple lines. Buttressing improved all types of staple lines.


Assuntos
Cirurgia Bariátrica/instrumentação , Intestino Delgado/cirurgia , Grampeadores Cirúrgicos , Anastomose Cirúrgica/instrumentação , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Falha de Equipamento , Obesidade Mórbida/cirurgia , Suínos
7.
Semin Pediatr Surg ; 15(4): 259-66, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17055956

RESUMO

Molecular imaging comprises a series of diagnostic modalities that provide information on the physiology and molecular composition of cells and tissues. One of these modalities, radioimmunodetection, uses radiolabeled monoclonal antibodies (mAbs) to image tissues. Two radioimmunodetection modalities are described in this article: immunoscintigraphy and radioimmunoguided surgery (RIGS). In immunoscintigraphy, the radioactivity is measured with the use of an external gamma camera and used to create images. In RIGS, the radioactivity is detected intraoperatively with the use of a handheld gamma probe to help the surgeon detect foci of otherwise occult disease. Both techniques have the potential to improve the preoperative and intraoperative localization of cancer. Multiple studies have been performed on the efficacy of RIGS on different malignancies, especially colorectal cancer. Despite the good sensitivity of the technique, some concerns revolve around the high rate of false positives and the real significance of leaving RIGS-positive tissue behind in terms of long-term outcomes and survival. More studies are warranted to further develop the technique and determine the specific role it will play on the diagnosis and management of surgical disease. Surgeons should actively participate in these studies and in expanding the applications of this promising technology.


Assuntos
Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Radioimunodetecção/instrumentação , Cirurgia Assistida por Computador/instrumentação , Criança , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Desenho de Equipamento , Câmaras gama , Humanos , Neoplasias Primárias Desconhecidas/diagnóstico por imagem , Neoplasias Primárias Desconhecidas/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Tomografia por Emissão de Pósitrons/instrumentação , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
8.
Semin Pediatr Surg ; 15(4): 251-8, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17055955

RESUMO

Surgery has rapidly evolved as new technologies are adopted. With the introduction of laparoscopic surgery, patient outcomes have improved, with faster recovery from smaller incisions. In an effort to continually improve these outcomes and offer alternative options to higher risk patients, a number of investigators have proposed the concept of operating in the peritoneal space through natural orifices, obviating the need for any abdominal skin incisions. Natural orifice translumenal endoscopic surgery (NOTES) offers the same advantages as laparoscopic surgery without skin incisions, and possibly without general anesthesia. This article gives a conceptual and technical description of NOTES, discusses its challenges and potential pitfalls, reviews the early efforts at NOTES-specific device development, and predicts potential future directions of this exciting new area of surgery.


Assuntos
Endoscópios , Endoscopia , Animais , Infecções Bacterianas/prevenção & controle , Infecções Bacterianas/transmissão , Criança , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/transmissão , Endoscópios/tendências , Endoscópios Gastrointestinais , Endoscopia/tendências , Desenho de Equipamento/tendências , Previsões , Humanos , Laparoscópios/tendências , Instrumentos Cirúrgicos/tendências
9.
Semin Pediatr Surg ; 15(4): 276-83, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17055958

RESUMO

Biomaterials offer the surgeon a powerful set of clinical tools for patient treatment and are found in virtually every instrument, device, implant, or piece of equipment in the operating room. In fact, surgeons have historically driven clinical application of biomaterials and stand uniquely positioned to contribute to the ongoing development of biomaterials. Having an understanding of the materials available and their basic properties can contribute to better and more effective outcomes. This article provides an overview of the biomaterials field. It begins with a definition and abbreviated history of the field, highlighting its clinical roots. An introduction to the four material classifications--metals, polymers, ceramics, and composites--is then presented, providing the reader with basic properties of each group and examples of materials. Sections on nanotechnology and tissue engineering also briefly describe development within the field. Finally, the evolution of treatments for pectus excavatum and congenital diaphragmatic hernias are presented, highlighting the role of biomaterials. While providing a primer of the field, this paper shows the broad interdisciplinary reach of material science in surgery and suggests sources for further investigations.


Assuntos
Materiais Biocompatíveis , Próteses e Implantes , Equipamentos Cirúrgicos , Instrumentos Cirúrgicos , Cerâmica , Criança , Resinas Compostas , Tórax em Funil/cirurgia , Hérnia Diafragmática/cirurgia , Hérnias Diafragmáticas Congênitas , Humanos , Metais , Polímeros
10.
Semin Pediatr Surg ; 15(4): 309-18, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17055962

RESUMO

Current surgical care and technology has evolved over the centuries from the interplay between creative surgeons and new technologies. As both fields become more specialized, that interplay is threatened. A 2-year educational fellowship is described which teaches both the process and the discipline of medical/surgical device innovation. Multi-disciplinary teams (surgeons, engineers, business grads) are assembled to educate a generation of translators, who can bridge the gap between scientific and technologic advances and the needs of the physician and the patient.


Assuntos
Difusão de Inovações , Educação de Pós-Graduação em Medicina , Engenharia/educação , Cirurgia Geral/educação , Ciência de Laboratório Médico/instrumentação , Equipamentos Cirúrgicos , Instrumentos Cirúrgicos , Apoio ao Desenvolvimento de Recursos Humanos , Criança , Currículo , Aprovação de Equipamentos , Humanos , Internato e Residência , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...