Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38437028

RESUMO

Nanopore-based sensing platforms have transformed single-molecule detection and analysis. The foundation of nanopore translocation experiments lies in conductance measurements, yet existing models, which are largely phenomenological, are inaccurate in critical experimental conditions such as thin and tightly fitting pores. Of the two components of the conductance blockade, channel and access resistance, the access resistance is poorly modeled. We present a comprehensive investigation of the access resistance and associated conductance blockade in thin nanopore membranes. By combining a first-principles approach, multiscale modeling, and experimental validation, we propose a unified theoretical modeling framework. The analytical model derived as a result surpasses current approaches across a broad parameter range. Beyond advancing our theoretical understanding, our framework's versatility enables analyte size inference and predictive insights into conductance blockade behavior. Our results will facilitate the design and optimization of nanopore devices for diverse applications, including nanopore base calling and data storage.

2.
Am J Ophthalmol Case Rep ; 34: 102009, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38501095

RESUMO

Purpose: Tube shunts can be inserted into the anterior chamber, ciliary sulcus, or pars plana. Sulcus tube placement can be challenging. This report demonstrates three techniques for guidewire-assisted sulcus tube insertion. Observations: The first technique uses a needle inserted through a paracentesis 180-degrees across from the tube entry site and creates an ab-interno sclerotomy through which the guidewire is inserted by docking it into the needle bevel. The second technique involves inserting the guidewire into the eye via a paracentesis and using microforceps to retrieve it through a sclerotomy. The third technique uses forceps to insert the guidewire into a paracentesis 180° across from the planned tube entry site and dock it into a needle bevel that has been inserted into the sulcus. Each of these techniques provides a reliable and reproducible way to insert a tube into the sulcus. Conclusions and importance: Guidewire-assisted tube entry offers a promising solution in cases of difficult sulcus tube placement without substantial additional cost.

3.
Invest Ophthalmol Vis Sci ; 64(15): 45, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38153747

RESUMO

Purpose: The pathogenesis of age-related macular degeneration (AMD) likely implicates the dysregulation of immune response pathways. Several studies demonstrate that the pathogenic elements of AMD resemble those of autoimmune diseases, yet the association between AMD development and most autoimmune diseases remain unexplored. Methods: We conducted a case-control analysis of patients ages 55 and older with new-onset International Classification of Diseases (ICD) coding of dry, wet, or unspecified AMD between 2005 and 2019 in the Merative MarketScan Commercial and Medicare Databases. The diagnosis of an autoimmune disease was defined by an outpatient or inpatient claim with a relevant ICD code in the 12 months before the index visit. Conditional multivariable logistic regression, adjusted for AMD risk factors, was used to calculate odd ratios and 95% confidence intervals. Results: We identified 415,027 cases with new-onset ICD coding for AMD matched with propensity scores to 414,853 controls. In total, 16.1% of cases and 15.9% of controls were diagnosed with any autoimmune disease. The diagnosis of any autoimmune disease did not affect the odds of new-onset ICD coding for AMD in multivariable regression (OR = 1.01; 95% CI, 0.999-1.02). Discoid lupus erythematosus (OR = 1.29; 95% CI, 1.12-1.48), systemic lupus erythematosus (SLE) (OR = 1.21; 95% CI, 1.15-1.27), giant cell arteritis (OR = 1.19; 95% CI, 1.09-1.30), Sjogren's syndrome (OR = 1.17; 95% CI, 1.09-1.26), and Crohn's disease (OR = 1.13; 95% CI, 1.06-1.22) increased the odds of a new-onset ICD coding for AMD. Conclusions: Most autoimmune diseases do not affect the odds of developing AMD but several common autoimmune disorders such as SLE and Crohn's disease were associated with modestly increased odds of AMD. Further studies are needed to validate and investigate the underlying mechanisms of these associations.


Assuntos
Doenças Autoimunes , Doença de Crohn , Lúpus Eritematoso Sistêmico , Degeneração Macular , Estados Unidos/epidemiologia , Humanos , Idoso , Medicare , Doenças Autoimunes/complicações , Doenças Autoimunes/epidemiologia , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/epidemiologia , Degeneração Macular/diagnóstico , Degeneração Macular/epidemiologia , Degeneração Macular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...