Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 6(6): e04124, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32548325

RESUMO

In this study, the binding tendency of bisnitrophenoxy compounds (BN) having different methylene (-CH2-)n spacer groups (n = 8-11) with fish sperm double stranded deoxyribonucleic acid (dsDNA) was explored. Cyclic voltammetry (CV) was used to evaluate various kinetic and binding parameters (Ks,h, Do, K b and binding site sizes). Performed electrochemical studies designated strong contact of these symmetric molecules with dsDNA in threading intercalation mode of binding. The number (n) of methylene spacer group in the molecular structure of bisnitrophenoxy compounds, e.g., BN-8 (1-nitro-4-(8-(4-nitrophenoxy)octyloxy)benzene, was observed to have a strong influence on their binding affinity. Decreased peak current values and positively shifted peak potentials recorded via cyclic voltammetry clearly depicted that bisnitrophenoxy compounds can intercalate with dsDNA. Results demonstrated the following order of binding constants; K b (M-1): BN-8 (2.32 × 104) < BN-9 (5.73 × 104) < BN-10 (8.97 × 104) < BN-11 (17.34 × 104). The order of increasing binding sites from BN-8 (0.13) to BN-11 (1.38), revealed the maximum threading intercalation strength by bisnitrophenoxy compound having the longest methylene spacer (n = 11). Thermodynamic studies augmented the strong binding of BN-11 with dsDNA as compared to BN-8 because of the long-chain, -CH2- spacer in its structure. The spontaneity of dsDNA-binding was revealed by the negative ΔG values for interaction of all the compounds. Moreover, binding parameters from thermodynamic and kinetic studies also corresponded to the threading intercalation mode of interaction, which itself points to the potency of the envisioned drug-like molecules.

2.
J Ayub Med Coll Abbottabad ; 30(4): 511-555, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30632326

RESUMO

BACKGROUND: Nasal continuous positive pressure has been used for management of respiratory distress in neonates in various conditions as a primary modality. Objective of the study is to evaluate the frequency of improved outcome and complications of use of nasal CPAP through infant flow drivers in neonates with respiratory distress. The study was conducted from 2nd April 2017 to 2nd October 2017 in neonatal intensive care unit of Allama Iqbal Memorial Teaching Hospital Sialkot. METHODS: All neonates with respiratory distress fulfilling the clinical criteria (Neonates with gestational age 28 weeks to 40 weeks having clinical signs of respiratory distress classified according to down score (tachypnea, grunting, decreased air entry, cyanosis, recessions), neonates having pc02 <60 mmhg, neonates having x-ray findings consistent with respiratory distress syndrome (RDS), Transient tachypnea of newborn (TTN) and pneumonia) were included in the study. Nasal CPAP was used at variable settings. Outcome, complications, indications, associated diseases and hospital stay along with other baseline characteristics were assessed. Success was defined as improvement of the respiratory distress as assessed by down score, maintenance of SPO2 above 90% in room air after weaning from CPAP for about consecutive 4 hours and normalization of blood gases while the failure as need for mechanical ventilation. RESULTS: Total 60 neonates were included in the study. Mean weight was 2113.3±580.32 g while mean gestational age was 33.35±2.59 weeks. Total 52 (86.7%) babies were successfully weaned off from nCPAP while only 8 (13.3%) neonates required mechanical ventilation. Main indication of use of CPAP was RDS (65%). No complications were observed in 73.3% babies while 26.7% had complications of which nasal deformities accounted for 20% and abdominal distension for 6.37%. CONCLUSIONS: Nasal CPAP can be safely and easily used as primary support for neonates with respiratory distress even in resource limited developing countries. It reduces the need for mechanical ventilation and thus hospital stay.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Estudos de Coortes , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Humanos , Recém-Nascido , Nariz/fisiologia , Paquistão , Respiração Artificial/efeitos adversos , Respiração Artificial/estatística & dados numéricos , Centros de Atenção Terciária , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...