Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JPEN J Parenter Enteral Nutr ; 21(3): 168-74, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9168370

RESUMO

BACKGROUND: There is no consensus regarding the optimal duration of measurement or time of day to perform indirect calorimetry (IC). Energy expenditure (EE) varies at different times of day and with different activity levels. We sought to assess the variability of EE in mechanically ventilated patients over a 24-hour period and the accuracy of 30-minute IC studies in predicting the 24-hour energy expenditure (EE24). METHODS: The study was a prospective comparison between the resting EE obtained by 30-minute measurement of IC and EE values obtained from 24-hour measurements. Tests were performed in the Medical Intensive Care Unit (MICU) of a tertiary care, university hospital. Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured for 24 hours in eight ventilated patients. Measurements were made every 3 minutes and used to calculate 30-minute and 24-hour oxygen consumption values. EE24 was calculated using the modified Weir equation. Each 30-minute interval was compared with the value obtained from the 24-hour measurement. RESULTS: Three hundred forty-one of 384 30-minute intervals remained for analysis. Average EE24 measured was 1490 +/- 486 kcal/d. Average EE24 predicted by extrapolation from 30-minute studies was 1501 +/- 503 kcal/d, with a mean difference of 0 +/- 209 kcal/d from the measured 24-hour values (range: -1068 to +585 kcal/d). Thirty-minute studies were within 20% of 24-hour measurements for 89% of intervals. The difference between 24-hour and 30-minute studies correlated with changes in minute ventilation (VE), heart rate, systolic blood pressure, and breath rate from their 24-hour means (p < .001). The mean error of EE estimate was greatest between 3 and 11 PM (p < .001). CONCLUSIONS: We conclude the following: (1) EE in MICU patients is variable; (2) 30-minute IC studies predict measured EE24 acceptably well for clinical purposes; and (3) accuracy is maximized if a 30-minute study is performed between 11 PM and 3 PM, and when Ve, heart rate, systolic blood pressure, and breath rate are near the day's average.


Assuntos
Calorimetria Indireta , Estado Terminal , Metabolismo Energético , Respiração Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Capnografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Consumo de Oxigênio , Reprodutibilidade dos Testes
2.
Pathol Int ; 45(10): 762-6, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8563938

RESUMO

A 17 year old female was seen because of a non-productive cough and one episode of blood-tinged sputum. A computerized tomography (CT) scan of the chest showed multiple small cystic lucencies in the upper lobes. The mediastinal CT window revealed concurrent mediastinal lymphadenopathy. An open lung biopsy showed Langerhans' cell histiocytosis (LCH). The significance of nodal involvement in LCH of the lung is not known, but raises the possibility of regional LCH and warrants a further search for bone or visceral involvement as well as closer follow-up and monitoring of patients.


Assuntos
Histiocitose de Células de Langerhans/complicações , Doenças Linfáticas/complicações , Doenças do Mediastino/complicações , Adolescente , Feminino , Histiocitose de Células de Langerhans/patologia , Humanos , Pulmão/patologia , Doenças Linfáticas/diagnóstico por imagem , Doenças do Mediastino/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...