Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Adv Mater ; : e2308802, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37878366

RESUMO

Single-crystal graphene (SCG) wafers are needed to enable mass-electronics and optoelectronics owing to their excellent properties and compatibility with silicon-based technology. Controlled synthesis of high-quality SCG wafers can be done exploiting single-crystal Cu(111) substrates as epitaxial growth substrates recently. However, current Cu(111) films prepared by magnetron sputtering on single-crystal sapphire wafers still suffer from in-plane twin boundaries, which degrade the SCG chemical vapor deposition. Here, it is shown how to eliminate twin boundaries on Cu and achieve 4 in. Cu(111) wafers with ≈95% crystallinity. The introduction of a temperature gradient on Cu films with designed texture during annealing drives abnormal grain growth across the whole Cu wafer. In-plane twin boundaries are eliminated via migration of out-of-plane grain boundaries. SCG wafers grown on the resulting single-crystal Cu(111) substrates exhibit improved crystallinity with >97% aligned graphene domains. As-synthesized SCG wafers exhibit an average carrier mobility up to 7284 cm2 V-1 s-1 at room temperature from 103 devices and a uniform sheet resistance with only 5% deviation in 4 in. region.

2.
Angew Chem Int Ed Engl ; 62(40): e202309732, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37580313

RESUMO

Heteroatom doping has emerged as a highly effective strategy to enhance the activity of metal-based electrocatalysts toward the oxygen evolution reaction (OER). It is widely accepted that the doping does not switch the OER mechanism from the adsorbate evolution mechanism (AEM) to the lattice-oxygen-mediated mechanism (LOM), and the enhanced activity is attributed to the optimized binding energies toward oxygen intermediates. However, this seems inconsistent with the fact that the overpotential of doped OER electrocatalysts (<300 mV) is considerably smaller than the limit of AEM (>370 mV). To determine the origin of this inconsistency, we select phosphorus (P)-doped nickel-iron mixed oxides as the model electrocatalysts and observe that the doping enhances the covalency of the metal-oxygen bonds to drive the OER pathway transition from the AEM to the LOM, thereby breaking the adsorption linear relation between *OH and *OOH in the AEM. Consequently, the obtained P-doped oxides display a small overpotential of 237 mV at 10 mA cm-2 . Beyond P, the similar pathway transition is also observed on the sulfur doping. These findings offer new insights into the substantially enhanced OER activity originating from heteroatom doping.

3.
Adv Mater ; 35(42): e2305598, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37433070

RESUMO

Hydrazine-assisted water electrolysis provides new opportunities to enable energy-saving hydrogen production while solving the issue of hydrazine pollution. Here, the synthesis of compressively strained Ni2 P as a bifunctional electrocatalyst for boosting both the anodic hydrazine oxidation reaction (HzOR) and cathodic hydrogen evolution reaction (HER) is reported. Different from a multistep synthetic method that induces lattice strain by creating core-shell structures, a facile strategy is developed to tune the strain of Ni2 P via dual-cation co-doping. The obtained Ni2 P with a compressive strain of -3.62% exhibits significantly enhanced activity for both the HzOR and HER than counterparts with tensile strain and without strain. Consequently, the optimized Ni2 P delivers current densities of 10 and 100 mA cm-2 at small cell voltages of 0.16 and 0.39 V for hydrazine-assisted water electrolysis, respectively. Density functional theory (DFT) calculations reveal that the compressive strain promotes water dissociation and concurrently tunes the adsorption strength of hydrogen intermediates, thereby facilitating the HER process on Ni2 P. As for the HzOR, the compressive strain reduces the energy barrier of the potential-determining step for the dehydrogenation of *N2 H4 to *N2 H3 . Clearly, this work paves a facile pathway to the synthesis of lattice-strained electrocatalysts via the dual-cation co-doping.

4.
Nat Commun ; 14(1): 3199, 2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268632

RESUMO

Bilayer graphene (BLG) is intriguing for its unique properties and potential applications in electronics, photonics, and mechanics. However, the chemical vapor deposition synthesis of large-area high-quality bilayer graphene on Cu is suffering from a low growth rate and limited bilayer coverage. Herein, we demonstrate the fast synthesis of meter-sized bilayer graphene film on commercial polycrystalline Cu foils by introducing trace CO2 during high-temperature growth. Continuous bilayer graphene with a high ratio of AB-stacking structure can be obtained within 20 min, which exhibits enhanced mechanical strength, uniform transmittance, and low sheet resistance in large area. Moreover, 96 and 100% AB-stacking structures were achieved in bilayer graphene grown on single-crystal Cu(111) foil and ultraflat single-crystal Cu(111)/sapphire substrates, respectively. The AB-stacking bilayer graphene exhibits tunable bandgap and performs well in photodetection. This work provides important insights into the growth mechanism and the mass production of large-area high-quality BLG on Cu.

5.
Angew Chem Int Ed Engl ; 62(15): e202300478, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36789622

RESUMO

Synergy engineering is an important way to enhance the kinetic activity of oxygen-evolution-reaction (OER) electrocatalysts. Here, we fabricated NiFe amorphous nanoreactor (NiFe-ANR) oxide as OER electrocatalysts via a mild self-catalytic reaction. Firstly, the amorphousness helps transform NiFe-ANR into highly active hydroxyhydroxides, and its many fine-grain boundaries increase active sites. More importantly, as proved by experiments and finite element analysis, the nanoreactor structure alters the spatial curvature and the mass transfer over the catalyst, thereby enriching OH- in the catalyst surface and inner part. Thus, the catalyst with the structure of amorphous nanoreactors gained excellent activity, far superior to the NiFe catalyst with the structure of crystalline nanoreactor or amorphous non-nanoreactor. This work provides new insights into the applications and mechanisms of amorphousness and nanoreactors, embodying the "1+1>2" synergy of crystalline state and morphology.

6.
Sci Adv ; 8(17): eabm6624, 2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35486719

RESUMO

Extremely fast-charging lithium-ion batteries are highly desirable to shorten the recharging time for electric vehicles, but it is hampered by the poor rate capability of graphite anodes. Here, we present a previously unreported particle size and electrode porosity dual-gradient structure design in the graphite anode for achieving extremely fast-charging lithium ion battery under strict electrode conditions. We develop a polymer binder-free slurry route to construct this previously unreported type particle size-porosity dual-gradient structure in the practical graphite anode showing the extremely fast-charging capability with 60% of recharge in 10 min. On the basis of dual-gradient graphite anode, we demonstrate extremely fast-charging lithium ion battery realizing 60% recharge in 6 min and high volumetric energy density of 701 Wh liter-1 at the high charging rate of 6 C.

7.
NMR Biomed ; 34(7): e4518, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33830561

RESUMO

Myocardial T1 reactivity, defined as the relative change in T1 between rest and vasodilator-induced stress, has been proposed as a magnetic resonance imaging (MRI) biomarker of tissue perfusion. We hypothesize that the superparamagnetic iron-oxide nanoparticle, ferumoxytol, sensitizes T1 to changes in the intramyocardial vascular compartment and improves the sensitivity and specificity of T1 reactivity as an imaging biomarker of tissue perfusion. We aim to assess the diagnostic performance of ferumoxytol-enhanced (FE) myocardial T1 reactivity in swine models of myocardial hypoperfusion. We induced acute myocardial hypoperfusion in 13 swine via percutaneous, transcatheter deployment of a 3D printed intracoronary stenosis implant into the left anterior descending coronary artery. We performed native and FE adenosine stress testing using 5(3)3(3)3 MOLLI and SASHA T1 mapping sequences with bSSFP readout on a clinical 3.0 T magnet. MOLLI T1 maps were fitted using both the conventional MOLLI and the Instantaneous Signal Loss (InSiL) T1-fitting algorithms. Regardless of the MOLLI or SASHA pulse sequence or T1-fitting algorithm, ferumoxytol contrast increased the dynamic range of T1 reactivity in both the remote and ischemic myocardial regions. Relative to remote myocardium, native and FE T1 reactivity were blunted in ischemic myocardium (p < 0.05) with InSiL-MOLLI, MOLLI and SASHA. An InSiL-MOLLI-derived FE T1 reactivity threshold of -4.65% had 73.3% sensitivity and 96.2% specificity for prediction of regional wall motion abnormalities (AUC 0.915, 95% CI 0.786-0.979), whereas a SASHA-derived FE T1 reactivity threshold of -5.25% had 75.0% sensitivity and 95.2% specificity (AUC 0.905, 95% CI 0.751-0.979). Ferumoxytol significantly increased the dynamic range of T1 reactivity as a measure of myocardial hypoperfusion in vasodilator stress T1 mapping studies. FE T1 reactivity maps can be used to quantitatively distinguish ischemic and remote myocardium with high specificity in swine models of acute myocardial hypoperfusion.


Assuntos
Óxido Ferroso-Férrico/química , Imageamento por Ressonância Magnética , Miocárdio/patologia , Animais , Humanos , Masculino , Curva ROC , Suínos
8.
J Cardiovasc Magn Reson ; 22(1): 85, 2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33302967

RESUMO

BACKGROUND: Cardiovascular disease is the leading cause of death in patients with Duchenne muscular dystrophy (DMD)-a fatal X-linked genetic disorder. Late gadolinium enhancement (LGE) imaging is the current gold standard for detecting myocardial tissue remodeling, but it is often a late finding. Current research aims to investigate cardiovascular magnetic resonance (CMR) biomarkers, including native (pre-contrast) T1 and extracellular volume (ECV) to evaluate the early on-set of microstructural remodeling and to grade disease severity. To date, native T1 measurements in DMD have been reported predominantly at 1.5T. This study uses 3T CMR: (1) to characterize global and regional myocardial pre-contrast T1 differences between healthy controls and LGE + and LGE- boys with DMD; and (2) to report global and regional myocardial post-contrast T1 values and myocardial ECV estimates in boys with DMD, and (3) to identify left ventricular (LV) T1-mapping biomarkers capable of distinguishing between healthy controls and boys with DMD and detecting LGE status in DMD. METHODS: Boys with DMD (N = 28, 13.2 ± 3.1 years) and healthy age-matched boys (N = 20, 13.4 ± 3.1 years) were prospectively enrolled and underwent a 3T CMR exam including standard functional imaging and T1 mapping using a modified Look-Locker inversion recovery (MOLLI) sequence. Pre-contrast T1 mapping was performed on all boys, but contrast was administered only to boys with DMD for post-contrast T1 and ECV mapping. Global and segmental myocardial regions of interest were contoured on mid LV T1 and ECV maps. ROI measurements were compared for pre-contrast myocardial T1 between boys with DMD and healthy controls, and for post-contrast myocardial T1 and ECV between LGE + and LGE- boys with DMD using a Wilcoxon rank-sum test. Results are reported as median and interquartile range (IQR). p-Values < 0.05 were considered significant. Receiver Operating Characteristic analysis was used to evaluate a binomial logistic classifier incorporating T1 mapping and LV function parameters in the tasks of distinguishing between healthy controls and boys with DMD, and detecting LGE status in DMD. The area under the curve is reported. RESULTS: Boys with DMD had significantly increased global native T1 [1332 (60) ms vs. 1289 (56) ms; p = 0.004] and increased within-slice standard deviation (SD) [100 (57) ms vs. 74 (27) ms; p = 0.001] compared to healthy controls. LGE- boys with DMD also demonstrated significantly increased lateral wall native T1 [1322 (68) ms vs. 1277 (58) ms; p = 0.001] compared to healthy controls. LGE + boys with DMD had decreased global myocardial post-contrast T1 [565 (113) ms vs 635 (126) ms; p = 0.04] and increased global myocardial ECV [32 (8) % vs. 28 (4) %; p = 0.02] compared to LGE- boys. In all classification tasks, T1-mapping biomarkers outperformed a conventional biomarker, LV ejection fraction. ECV was the best performing biomarker in the task of predicting LGE status (AUC = 0.95). CONCLUSIONS: Boys with DMD exhibit elevated native T1 compared to healthy, sex- and age-matched controls, even in the absence of LGE. Post-contrast T1 and ECV estimates from 3T CMR are also reported here for pediatric patients with DMD for the first time and can distinguish between LGE + from LGE- boys. In all classification tasks, T1-mapping biomarkers outperform a conventional biomarker, LVEF.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Distrofia Muscular de Duchenne/complicações , Miocárdio/patologia , Função Ventricular Esquerda , Remodelação Ventricular , Adolescente , Fatores Etários , California , Cardiomiopatias/etiologia , Cardiomiopatias/patologia , Cardiomiopatias/fisiopatologia , Estudos de Casos e Controles , Criança , Meios de Contraste/administração & dosagem , Humanos , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Distrofia Muscular de Duchenne/diagnóstico , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Adulto Jovem
9.
Phys Med Biol ; 65(17): 175006, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32554891

RESUMO

The objective of this study was to explore radiomics features from longitudinal diffusion-weighted MRIs (DWIs) for pathologic treatment effect prediction in patients with localized soft tissue sarcoma (STS) undergoing hypofractionated preoperative radiotherapy (RT). Thirty patients with localized STS treated with preoperative hypofractionated RT were recruited to this longitudinal imaging study. DWIs were acquired at three time points using a 0.35 T MRI-guided radiotherapy system. Treatment effect score (TES) was obtained from the post-surgery pathology as a surrogate of treatment outcome. Patients were divided into two groups based on TES. Response prediction was first performed using a support vector machine (SVM) with only mean apparent diffusion coefficient (ADC) or delta ADC to serve as the benchmark. Radiomics features were then extracted from tumor ADC maps at each of the three time points. Logistic regression and SVM were constructed to predict the TES group using features selected by univariate analysis and sequential forward selection. Classification performance using SVM with features from different time points and with or without delta radiomics were evaluated. Prediction performance using only mean ADC or delta ADC was poor (area under the curve (AUC) < 0.7). For the radiomics study using features from all time points and corresponding delta radiomics, SVM significantly outperformed logistic regression (AUC of 0.91 ± 0.05 v.s. 0.85 ± 0.06). Prediction AUC values using single or multiple time points without delta radiomics were all below 0.74. Including delta radiomics of mid- or post-treatment relative to the baseline drastically boosted the prediction. In this work, an SVM model was built to predict the TES using radiomics features from longitudinal DWI. Based on this study, we found that use of mean ADC, delta ADC, or radiomics features alone was not sufficient for response prediction, and including delta radiomics features of mid- or post-treatment relative to the baseline can optimize the prediction of TES, a pathologic and clinical endpoint.


Assuntos
Imagem de Difusão por Ressonância Magnética , Período Pré-Operatório , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/radioterapia , Área Sob a Curva , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Neoplasias de Tecidos Moles/cirurgia , Máquina de Vetores de Suporte , Resultado do Tratamento
10.
J Cardiovasc Transl Res ; 13(6): 1033-1043, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32394352

RESUMO

Reliable, closed-chest methods for creating large animal models of acute myocardial hypoperfusion are limited. We demonstrated the feasibility and efficacy of using magnetic resonance (MR)-compatible 3D-printed coronary implants for establishing swine models of myocardial hypoperfusion. We designed, manufactured, and percutaneously deployed implants in 13 swine to selectively create focal coronary stenosis. To test the efficacy of the implants to cause hypoperfusion or ischemia in the perfused territory, we evaluated regional wall motion, myocardial perfusion, and infarction using MR imaging. The overall swine survival rate was 85% (11 of 13). The implant retrieval rate was 92% (12 of 13). Fluoroscopic angiography confirmed focal stenosis. Cine and perfusion MRI showed regional wall motion abnormalities and inducible ischemia, respectively. Late gadolinium enhancement and histopathology showed no myocardial infarction. Our minimally invasive technique has promising applications for validation of new diagnostic methods in cardiac MR. Graphical abstract Our new minimally invasive, percutaneous method for creating swine models of acute focal coronary stenosis can be used for magnetic resonance imaging studies of myocardial ischemia. Comparable to existing methods in its efficacy and reliability, this rapid prototyping technique will allow researchers to more easily conduct translational cardiac imaging studies of coronary artery disease in large animal models.


Assuntos
Estenose Coronária/etiologia , Infarto do Miocárdio/etiologia , Impressão Tridimensional , Desenho de Prótese , Implantação de Prótese/instrumentação , Animais , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Modelos Animais de Doenças , Estudos de Viabilidade , Imagem Cinética por Ressonância Magnética , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Imagem de Perfusão do Miocárdio , Estudo de Prova de Conceito , Sus scrofa
11.
Magn Reson Med ; 84(5): 2831-2845, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32416010

RESUMO

PURPOSE: To propose and evaluate a deep learning model for rapid and accurate calculation of myocardial T1 /T2 values based on a previously proposed Bloch equation simulation with slice profile correction (BLESSPC) method. METHODS: Deep learning Bloch equation simulations (DeepBLESS) models are proposed for rapid and accurate T1 estimation for the MOLLI T1 mapping sequence with balanced SSFP readouts and T1 /T2 estimation for a radial simultaneous T1 and T2 mapping (radial T1 -T2 ) sequence. The DeepBLESS models were trained separately based on simulated radial T1 -T2 and MOLLI data, respectively. The DeepBLESS T1 -T2 estimation accuracy was evaluated based on simulated data with different noise levels. The DeepBLESS model was compared with BLESSPC in simulation, phantom, and in vivo studies for the MOLLI sequence at 1.5 T and radial T1 -T2 sequence at 3 T. RESULTS: After DeepBLESS was trained, in phantom studies, DeepBLESS and BLESSPC achieved similar accuracy and precision in T1 -T2 estimations for both MOLLI and radial T1 -T2 (P > .05). For in vivo, DeepBLESS and BLESSPC generated similar myocardial T1 /T2 values for radial T1 -T2 at 3 T (T1 : 1366 ± 31 ms for both methods, P > .05; T2 : 37.4 ms ± 0.9 ms for both methods, P > .05), and similar myocardial T1 values for the MOLLI sequence at 1.5 T (1044 ± 20 ms for both methods, P > .05). DeepBLESS generated a T1 /T2 map in less than 1 second. CONCLUSION: The DeepBLESS model offers an almost instantaneous approach for estimating accurate T1 /T2 values, replacing BLESSPC for both MOLLI and radial T1 -T2 sequences, and is promising for multiparametric mapping in cardiac MRI.


Assuntos
Aprendizado Profundo , Coração , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio , Imagens de Fantasmas , Reprodutibilidade dos Testes
12.
Quant Imaging Med Surg ; 9(9): 1516-1527, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31667138

RESUMO

BACKGROUND: To review and evaluate approaches to convolutional neural network (CNN) reconstruction for accelerated cardiac MR imaging in the real clinical context. METHODS: Two CNN architectures, Unet and residual network (Resnet) were evaluated using quantitative and qualitative assessment by radiologist. Four different loss functions were also considered: pixel-wise (L1 and L2), patch-wise structural dissimilarity (Dssim) and feature-wise (perceptual loss). The networks were evaluated using retrospectively and prospectively under-sampled cardiac MR data. RESULTS: Based on our assessments, we find that Resnet and Unet achieve similar image quality but that former requires only 100,000 parameters compared to 1.3 million parameters for the latter. The perceptual loss function performed significantly better than L1, L2 or Dssim loss functions as determined by the radiologist scores. CONCLUSIONS: CNN image reconstruction using Resnet yields comparable image quality to Unet with 10X the number of parameters. This has implications for training with significantly lower data requirements. Network training using the perceptual loss function was found to better agree with radiologist scoring compared to L1, L2 or Dssim loss functions.

13.
NMR Biomed ; 32(11): e4165, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31461194

RESUMO

We propose a simultaneous myocardial T1 and T2 mapping technique using a radial sequence with inversion recovery and T2 preparation, which achieves high accuracy and precision, with T1 and T2 reproducibility similar to the Modified Look-Locker Inversion recovery (MOLLI) sequence and the conventional bright blood T2 mapping technique, respectively. The sequence was developed by incorporating gold angle radial fast low angle shot (FLASH) readout combined with an inversion pulse and T2prep pulses. The extended Bloch equation simulation with slice profile correction (BLESSPC) algorithm was proposed to reconstruct T1 and T2 maps at the same time in a few seconds, while maintaining good T1 and T2 estimation accuracy. Accuracy and precision were compared among the proposed technique, MOLLI and conventional T2 mapping techniques using phantom studies, 10 healthy volunteers and three patients. In phantom studies, the proposed technique was more accurate than MOLLI (P < 0.05) while achieving similar precision (P = 0.3) in T1 estimation, and was more accurate (P < 0.05) and precise (P < 0.001) than conventional T2 mapping (two-parameter fitting) in T2 estimation. In vivo, the proposed technique achieved significantly higher T1 values (P < 0.001) and similar reproducibility (P = 0.3) compared with MOLLI, with significantly lower T2 values (P < 0.001) and similar reproducibility (P = 0.6) compared with the conventional T2 mapping technique. Thus, the proposed radial T1-T2 mapping technique allows for accurate, precise, simultaneous myocardial T1 and T2 mapping in an 11-heartbeat single breath-hold acquisition.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Algoritmos , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Adulto Jovem
14.
ACS Appl Mater Interfaces ; 11(18): 16578-16585, 2019 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-31010282

RESUMO

All solid-state lithium (Li) metal batteries (SSLMBs) are attractive for prospective electrochemical energy storage systems on account of their high energy densities and good safeties. However, the incompatible interface between the solid-state electrolyte and Li metal anode limits the ability of SSLMBs. Here, a three-dimensional (3D) electronic and ionic mixed conducting interlayer is proposed to improve the interfacial affinity in SSLMBs. The 3D electronic and ionic mixed conducting interlayer is composed of a Sn/Ni alloy layer-coated Cu nanowire (Cu@SnNi) network. The Li plating demonstrates that the Cu@SnNi network can possess fast Li+ ion transport channels from the Li metal to LiFePO4, acting as a stable interlayer between the Li metal and solid polymer electrolyte. Noticeably, the solid-state LiFePO4/Li cell with a Cu@SnNi interlayer exhibits an excellent rate capability (133 mA h g-1, 2 C; 100 mA h g-1, 5 C) in comparison to the low rate performance of the cell without the interlayer (117 mA h g-1, 2 C; 60 mA h g-1, 5 C). This unique structure design of electronic and ionic mixed conducting interlayer provides an alternative strategy to improve the performance of SSLMBs.

16.
Medicine (Baltimore) ; 98(13): e14899, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30921187

RESUMO

This study aimed to compare the clinical efficacy of stenting compared with standardized medical treatment in patients with moderate to severe vertebral artery origin stenosis (VAOS).Patients diagnosed with moderate to severe VAOS and indicated to undergo vertebral artery stenting were enrolled. Patients were divided into stenting group and standardized medical treatment group. All patients underwent transcranial Doppler (TCD) before and after treatment. Incidence of new cerebral infarction, transient ischemic attack (TIA), improvement of clinical symptoms, and National Institutes of Health Stroke Scale (NIHSS) score were observed.A total of 98 patients were enrolled. Vertebral artery stenting implant was accepted by 43 patients. Two weeks after treatment, the NIHSS score in the stenting group decreased significantly compared to that in the standardized medical treatment group. The modified Rankin Scale (mRS) score in the stenting group at three months was significantly lower than that in the medical treatment group (P = .044). The extent of vascular stenosis in the stent group decreased significantly (76.5 ±â€Š10.0% vs. 13.7 ±â€Š5.9%, t = 35.878, P = .000). The adverse events occurred in 9 (16.4%) patients in the medical treatment group and 5 (11.6%) in the stenting group (P = .506). There was one case with new cerebral infarction in the stenting group, whereas the medical treatment group showed 1 case with TIA and three with new cerebral infarction during follow-up after 3 months. The peak systolic velocity (PSV), end diastolic velocity (EDV), pulsatility index (PI) of stenosis vertebral artery, and PSV of basilar artery were significantly higher in the stent group than those in the standardized medical group (P < .05).Stenting for VAOS, rather than standardized medical treatment, can effectively relieve vascular stenosis, alter vertebral-basilar artery hemodynamics, and improve neurological function, with low perioperative complications.


Assuntos
Hemodinâmica/fisiologia , Stents/efeitos adversos , Artéria Vertebral/diagnóstico por imagem , Insuficiência Vertebrobasilar/diagnóstico por imagem , Idoso , Constrição Patológica/patologia , Feminino , Seguimentos , Humanos , Incidência , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados não Aleatórios como Assunto , Prognóstico , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Ultrassonografia Doppler Transcraniana/métodos , Artéria Vertebral/patologia , Insuficiência Vertebrobasilar/mortalidade , Insuficiência Vertebrobasilar/terapia
17.
NMR Biomed ; 31(5): e3904, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29517139

RESUMO

The aim of this work was to develop and evaluate a fast phase contrast magnetic resonance imaging (PC-MRI) technique with hybrid one- and two-sided flow encodings only (HOTFEO) for accurate blood flow and velocity measurements of three-directional velocity encoding PC-MRI. Four-dimensional (4D) PC-MRI acquires flow-compensated (FC) and three-directional flow-encoded (FE) echoes in an interleaved fashion. We hypothesize that the blood flow velocity direction (not magnitude) has minimal change between two consecutive cardiac phases. This assumption provides a velocity direction constraint that can achieve 4/3-fold acceleration using three-directional FE data to calculate FC data instead of acquiring them. The HOTFEO acquisition pattern can address the ill-conditioned constraint and improve the calculation accuracy. HOTFEO was evaluated in healthy volunteers and compared with conventional two-dimensional (2D) and 4D flow imaging techniques with FC and three-directional FE acquisitions (FC/3FE). Compared with FC/3FE, Bland-Altman tests showed that the 4/3-fold accelerated HOTFEO technique resulted in relatively small bias error for total volumetric flow (0.89% for prospective 2D data, -1.19% for retrospective 4D data and -3.40% for prospective 4D data) and maximum peak velocity (0.50% for prospective 2D data, -0.17% for retrospective 4D data and -2.00% for prospective 4D data) measurements in common carotid arteries. HOTFEO can accelerate three-directional velocity encoding PC-MRI whilst maintaining the measurement accuracy of the total volumetric flow and maximum peak velocity.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Reologia , Aceleração , Simulação por Computador , Humanos , Análise Numérica Assistida por Computador , Razão Sinal-Ruído
18.
Quant Imaging Med Surg ; 7(2): 177-186, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28516043

RESUMO

BACKGROUND: Assessment of lung function is vital for the diagnosis of a variety of pathological conditions. Research has been proposed to study pulmonary mechanics and kinematics using two-dimensional (2D) magnetic resonance imaging (MRI). This allows estimation of regional lung tissue mechanics but is limited to 2D information. An approach based on three-dimensional (3D) contrast-enhanced MR angiogram of pulmonary blood vessels and a non-rigid image registration technique is proposed for quantification of lung regional deformations, which can potentially be used for assessment of pulmonary parenchymal mechanics and regional ventilation for disease diagnosis without ionizing radiation. METHODS: On three volunteers, an end-expiration scan and end-inspiration scan was acquired successively for each volunteer using a 3D breath-hold contrast-enhanced MRI sequence several minutes after gadolinium injection. Subsequently, a rectangle box lung mask is manually selected for each end-expiration scan, applying non-rigid registration algorithms using cubic B-splines as transformations to align each pair of images. This incorporates the Normalized Correlation Coefficient similarity with the bending energy term as cost function with a multi-resolution multi-grid approach. Finally, the lung regional 3D deformations were obtained using the transformations obtained by registration. The alignment accuracy after non-rigid registration was estimated by using a set of branch points of pulmonary blood vessels as anatomical landmarks for each pair of images. RESULTS: With contrast enhancement, the pulmonary blood vessel signal was enhanced, which greatly facilitated the non-rigid registration in the lung parenchyma. The average landmarks distances in three pairs of datasets are reduced from 17.9, 20.3 and 16.3 mm, to 1.0, 1.6 and 1.2 mm, respectively, by non-rigid registration. After registration, the average distances error of each pair of datasets was less than 0.6 mm in the right-to-left (RL) direction, less than 0.9 mm in the inferior-to-superior (IS) direction, and less than 1.2 mm in the anterior-to-posterior (AP) direction. CONCLUSIONS: Results demonstrated that the proposed method can accurately register lungs with large deformations to evaluate lung regional deformation. It may be used for quantitative assessment of 3D lung regional ventilation avoiding ionizing radiation.

19.
Magn Reson Med ; 77(4): 1495-1504, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27018872

RESUMO

PURPOSE: To develop and validate a technique for myocardial T1 mapping in patients with implantable cardioverter defibrillators (ICDs). METHODS: A MOLLI-based pulse sequence, named Wideband-FLASH-MOLLI, was developed by incorporating a fast low angle shot (FLASH) readout and a wideband inversion pulse. The performance of Wideband-FLASH-MOLLI was evaluated using phantom studies and validated in eight healthy volunteers and ten patients with ICDs at 1.5 Tesla. Comparisons were made between Wideband-FLASH-MOLLI, FLASH-MOLLI, and bSSFP-MOLLI sequences. RESULTS: In phantom studies, the maximum T1 estimation errors using Wideband-FLASH-MOLLI with and without an ICD were less than 3% for T1 range from 212 to 1673 ms. In all healthy volunteers, there was no significant native myocardial T1 estimation difference using Wideband-FLASH-MOLLI before and after the external attachment of an ICD to the body coil (1178 ± 27 ms versus 1174 ± 33 ms; P = 0.41). Due to the presence of an ICD, the magnitude images acquired using bSSFP-MOLLI and FLASH-MOLLI showed severe artifacts within the myocardium. In contrast, no or negligible device-induced artifacts were noted within the myocardial regions of the healthy volunteers or the patients with ICDs when using Wideband-FLASH-MOLLI. CONCLUSION: This study demonstrates the feasibility of using Wideband-FLASH-MOLLI to mitigate image artifacts and to produce accurate myocardial T1 maps in patients with ICDs. Magn Reson Med 77:1495-1504, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Artefatos , Técnicas de Imagem Cardíaca/métodos , Desfibriladores Implantáveis , Coração/anatomia & histologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Magn Reson Med ; 78(5): 1746-1756, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-27917529

RESUMO

PURPOSE: To compare the accuracy and precision of four different T1 estimation algorithms for modified Look-Locker inversion recovery (MOLLI). METHODS: Four T1 estimation algorithms, including the original fit, inversion group (IG) fit, instantaneous signal loss simulation (InSiL), and Bloch equation simulation with slice profile correction (BLESSPC) were studied. T1 estimation accuracy, precision, reproducibility, and sensitivity to heart rate (HR), flip angle (FA), and acquisition scheme (AcS) variations were compared in simulation, phantom, and volunteer studies. RESULTS: T1 estimation accuracy of IG (-2.4% ± 3.9%) and original fit (-3.2% ± 1.4%) were worse than BLESSPC (0.2% ± 1.5%) and InSiL (-0.7% ± 2.1%). The original fit had the best precision for T1 from 409-1884 ms for the same FA (0.67% ± 0.16% versus 0.90% ± 0.23% using IG, 0.78% ± 0.11% using InSiL, 0.77% ± 0.12% using BLESSPC). BLESSPC generated the most consistent in vivo T1 values over different FAs and AcS, and the T1 estimation reproducibility was similar (P > 0.3) among the four methods when FA = 35°. When using FA = 50°, the reproducibility was significantly improved only when using BLESSPC (1.6% ± 0.9 versus 2.6% ± 1.9%, P < 0.05). CONCLUSION: BLESSPC has superior accuracy and is the least sensitive to FA, HR, and AcS variations. T1 estimation using BLESSPC and FA = 50° is superior to conventional MOLLI with FA = 35° in accuracy and precision. Further clinical studies in varying pathological conditions are warranted to confirm our findings. Magn Reson Med 78:1746-1756, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Simulação por Computador , Feminino , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...