Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Huan Jing Ke Xue ; 39(10): 4621-4627, 2018 Oct 08.
Artigo em Chinês | MEDLINE | ID: mdl-30229610

RESUMO

Low C/N domestic sewage was treated by an A2/O-biological aerated filter (BAF) system at low temperatures (11-14℃). The characteristics of pollutant removal, the ratio of denitrifying phosphorus to nitrogen (ΔPO43-/ΔNO3-N) and effects of aeration flow and effective packing height on nitrification in BAF were studied. The results showed that when the average influent concentrations of COD, NH4+-N, TN and PO43- were 193.1, 58.6, 60.3 and 5.1 mg·L-1 respectively, their effluent concentrations were 46.3, 2.5, 13.4 and 0.3 mg·L-1 respectively, which met the first level A criteria specified in the discharge standard of pollutants for municipal wastewater treatment plant (GB 18918-2002). The linear fitting of ΔPO43-/ΔNO3--N was between 0.47 and 1.75. The normal distribution of mathematical statistics was applied-and the average standard deviation for ΔPO43-/ΔNO3--N were 1.20 and 0.29 respectively. When the aeration flows were 60 L·h-1 and 100 L·h-1, the effluent concentration of NH4+-N was less than 5.0 mg·L-1, corresponding to the effective packing heights in the BAF of 1.8 m and 1.0 m respectively. However, when the aeration flow was increased to 120 L·h-1, the air-water flow led to biofilm detachment, which caused the effluent concentration of NH4+-N to increase beyond 5.0 mg·L-1.


Assuntos
Reatores Biológicos , Desnitrificação , Fósforo/isolamento & purificação , Eliminação de Resíduos Líquidos , Análise da Demanda Biológica de Oxigênio , Filtração , Nitrogênio , Esgotos , Temperatura
2.
Huan Jing Ke Xue ; 39(9): 4302-4309, 2018 Sep 08.
Artigo em Chinês | MEDLINE | ID: mdl-30188075

RESUMO

Real domestic sewage was first treated in SBR and partial nitrification was achieved. When average concentrations of NH4+-N, NO2--N, and COD were 37.27, 39.97, and 120 mg·L-1, respectively, the effluent was delivered as influent of an anaerobic ammonia oxidation reactor (ASBR). The effect of different HRTs (36 h, 33 h, 30 h, 27 h) on nitrogen removal of ANAMMOX and heterotrophic denitrification were investigated under conditions of temperature of 24℃ and pH of 7.2±0.2. Results showed that 1 nitrogen removal efficiency was optimum with HRT of 33 h. The average total nitrogen load rate(TNLR)and total nitrogen removal rate(TNRR)were 0.056 kg·(m3·d)-1and 0.050 kg·(m3·d)-1, respectively. The average effluent concentrations of NH4+-N, NO2--N, and COD were 1.36, 0.47, and 49.79 mg·L-1, and removal rates were 96.30%, 98.83%, and 56.17%, respectively. △NO2--N/△NH4+-N and △NO3--N/△NH4+-N were 1.17 and 0.15, 0.15 and 0.11 less than theoretical ANAMMOX values (1.32, 0.26) due to heterotrophic denitrification. 2 The contribution of ANAMMOX to nitrogen removal decreased; however, the contribution of heterotrophic denitrification to nitrogen removal gradually increased with decreasing HRT. This provides a point of reference for ANAMMOX in engineering applications.


Assuntos
Reatores Biológicos , Desnitrificação , Nitrogênio/isolamento & purificação , Esgotos , Anaerobiose , Análise da Demanda Biológica de Oxigênio , Nitrificação , Oxirredução
3.
Huan Jing Ke Xue ; 39(6): 2770-2777, 2018 Jun 08.
Artigo em Chinês | MEDLINE | ID: mdl-29965634

RESUMO

The effects of low substrate ratio, cooling methods, and pH on nitrogen removal performance were studied in a laboratory-scale anaerobic ammonium oxidation reactor (ASBR) while treating simulated domestic waste water. The results illustrated that the average removal efficiencies of NH4+-N and NO2--N increased from 54.4% and 65.3% to 95.8% and 92.5%, respectively, at a temperature of 30℃ and an influent concentration of NO2--N of (30±0.2)mg·L-1. The substrate ratio (NO2--N/NH4+-N) increased from 0.9 to 1.4.However, the removal efficiency of NH4+-N was affected negligibly, and the average removal efficiency of NO2--N decreased to 54.6% when the substrate ratio was increased to 1.6, suggesting that the nitrogen removal performance of anaerobic ammonium oxidation was best when the substrate ratio was close to the theoretical value of 1.32.The average removal efficiencies of NH4+-N and NO2--N decreased from 97.5% and 98.5% to 35.2% and 40.1%, respectively, when the temperature of the reactor dropped from 30℃ to 15℃ at one time. The average removal efficiencies of NH4+-N and NO2--N dropped from 97.7% and 98.6% to 52.7% and 62.4%, respectively, when the ladder cooling method(30℃→25℃→20℃→15℃) was used. The average removal efficiencies of NH4+-N and NO2--N increased initially and then decreased when the pH was increased gradually from 7.7 to 8.5.The highest nitrogen removal efficiency was achieved when the pH was controlled at 8.3 with a substrate ratio of NO2--N/NH4+-N equal to 1.4.


Assuntos
Amônia/metabolismo , Nitrogênio/isolamento & purificação , Eliminação de Resíduos Líquidos , Águas Residuárias , Anaerobiose , Reatores Biológicos , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...