Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Case Rep ; 12(2): e8509, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333653

RESUMO

Key Clinical Message: Gastric outlet obstruction can be a dangerous complication of intragastric balloons, as it can result in severe metabolic alkalosis. As weight loss procedures and medical tourism become more popular, physicians should have a high index of suspicion for complications of invasive procedures, particularly in returning travelers. Abstract: Intragastric balloons for weight loss have decreased in frequency in the United States. However, they are still frequent in low- and middle-income countries. Severe complications occur in less than 3% of patients who undergo this procedure. Herein, we present a case of gastric outlet obstruction, severe metabolic alkalosis, and refeeding syndrome in a patient returning from the Dominican Republic. She presented with 2 weeks of emesis and obstipation, followed by a pre-syncope and altered mental status. An intragastric mass was observed on computerized tomography, which was characterized as an intragastric balloon and retrieved endoscopically. All metabolic derangements were corrected, and the patient improved without sequelae. As weight loss procedures and medical tourism become more popular, physicians should have a high index of suspicion for complications of invasive procedures, particularly in returning travelers.

2.
J Med Internet Res ; 25: e43123, 2023 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-36877540

RESUMO

BACKGROUND: Physical inactivity is a known risk factor for atrial fibrillation (AF). Wearable devices, such as smartwatches, present an opportunity to investigate the relation between daily step count and AF risk. OBJECTIVE: The objective of this study was to investigate the association between daily step count and the predicted 5-year risk of AF. METHODS: Participants from the electronic Framingham Heart Study used an Apple smartwatch. Individuals with diagnosed AF were excluded. Daily step count, watch wear time (hours and days), and self-reported physical activity data were collected. Individuals' 5-year risk of AF was estimated, using the Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE)-AF score. The relation between daily step count and predicted 5-year AF risk was examined via linear regression, adjusting for age, sex, and wear time. Secondary analyses examined effect modification by sex and obesity (BMI≥30 kg/m2), as well as the relation between self-reported physical activity and predicted 5-year AF risk. RESULTS: We examined 923 electronic Framingham Heart Study participants (age: mean 53, SD 9 years; female: n=563, 61%) who had a median daily step count of 7227 (IQR 5699-8970). Most participants (n=823, 89.2%) had a <2.5% CHARGE-AF risk. Every 1000 steps were associated with a 0.08% lower CHARGE-AF risk (P<.001). A stronger association was observed in men and individuals with obesity. In contrast, self-reported physical activity was not associated with CHARGE-AF risk. CONCLUSIONS: Higher daily step counts were associated with a lower predicted 5-year risk of AF, and this relation was stronger in men and participants with obesity. The utility of a wearable daily step counter for AF risk reduction merits further investigation.


Assuntos
Fibrilação Atrial , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/epidemiologia , Estudos Transversais , Autorrelato , Genômica , Obesidade
3.
J Am Med Inform Assoc ; 30(6): 1047-1055, 2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36921287

RESUMO

OBJECTIVE: To adapt and validate an algorithm to ascertain transgender and gender diverse (TGD) patients within electronic health record (EHR) data. METHODS: Using a previously unvalidated algorithm of identifying TGD persons within administrative claims data in a multistep, hierarchical process, we validated this algorithm in an EHR data set with self-reported gender identity. RESULTS: Within an EHR data set of 52 746 adults with self-reported gender identity (gold standard) a previously unvalidated algorithm to identify TGD persons via TGD-related diagnosis and procedure codes, and gender-affirming hormone therapy prescription data had a sensitivity of 87.3% (95% confidence interval [CI] 86.4-88.2), specificity of 98.7% (95% CI 98.6-98.8), positive predictive value (PPV) of 88.7% (95% CI 87.9-89.4), and negative predictive value (NPV) of 98.5% (95% CI 98.4-98.6). The area under the curve (AUC) was 0.930 (95% CI 0.925-0.935). Steps to further categorize patients as presumably TGD men versus women based on prescription data performed well: sensitivity of 97.6%, specificity of 92.7%, PPV of 93.2%, and NPV of 97.4%. The AUC was 0.95 (95% CI 0.94-0.96). CONCLUSIONS: In the absence of self-reported gender identity data, an algorithm to identify TGD patients in administrative data using TGD-related diagnosis and procedure codes, and gender-affirming hormone prescriptions performs well.


Assuntos
Pessoas Transgênero , Adulto , Humanos , Masculino , Feminino , Identidade de Gênero , Autorrelato , Registros Eletrônicos de Saúde , Algoritmos , Hormônios
4.
JACC Clin Electrophysiol ; 8(4): 498-510, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35450605

RESUMO

OBJECTIVES: This study sought to examine the effect of the return electrode's surface area on bipolar RFA lesion size. BACKGROUND: Bipolar radiofrequency ablation (RFA) is typically performed between 2 3.5-mm tip catheters serving as active and return electrodes. We hypothesized that increasing the surface area of the return electrode would increase lesion dimensions by reducing the circuit impedance, thus increasing the current into a larger tissue volume enclosed between the electrodes. METHODS: In step 1, ex vivo bipolar RFA was performed between 3.5-mm and custom-made return electrodes with increasing surface areas (20, 80, 180 mm2). In step 2, ex vivo bipolar RFA was performed between 3.5-mm and 3.5-mm or 8-mm electrode catheters positioned perpendicular or parallel to the tissue. In step 3, in vivo bipolar RFA was performed between 3.5-mm and either 3.5-mm or 8-mm parallel electrode at the: 1) left ventricular summit; 2) interventricular septum; and 3) healed anterior infarction. RESULTS: In step 1, increasing the surface area of the return electrode resulted in lower circuit impedance (R = -0.65; P < 0.001), higher current (R = +0.80; P < 0.001), and larger lesion volume (R = +0.88; P < 0.001). In step 2, an 8-mm return electrode parallel to tissue produced larger and deeper lesions compared with a 3.5-mm return electrode (P = 0.014 and P = 0.02). Similarly, in step 3, compared with a 3.5-mm, bipolar RFA with an 8-mm return electrode produced larger (volume: 1,525 ± 871 mm3 vs 306 ± 310 mm3, respectively; P < 0.001) and more transmural lesions (88% vs 0%; P < 0.001). CONCLUSIONS: Bipolar RFA using an 8-mm return electrode positioned parallel to the tissue produces larger lesions in comparison with a 3.5-mm return electrode.


Assuntos
Ablação por Cateter , Ablação por Cateter/métodos , Eletrodos , Desenho de Equipamento , Ventrículos do Coração/cirurgia , Humanos
5.
J Cardiothorac Surg ; 17(1): 68, 2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35382843

RESUMO

BACKGROUND: Long-term survival is an important metric in assessing procedural value. We previously confirmed that the Society of Thoracic Surgeons predicted risk of mortality score (PROM) accurately predicts 30-day mortality in Israeli patients. The present study investigated the ability of the PROM to reliably predict long-term survival. METHODS: Data on 1279 patients undergoing cardiac surgery were prospectively entered into our database and used to calculate PROM. Long-term mortality was obtained from the Israeli Social Security Database. Patients were stratified into five cohorts according to PROM (A: 0-0.99%, B: 1.0-1.99%, C: 2.0-2.99%, D: 3.0-4.99% and E: ≥ 5.0%). Kaplan-Meier estimates of survival were calculated for each cohort and compared by Wilcoxon signed-rank test. We used C-statistics to assess model discrimination. Cox regression analysis was performed to identify predictors of long-term survival. RESULTS: Follow-up was achieved for 1256 (98%) patients over a mean period of 62 ± 28 months (median 64, range 0-107). Mean survival of the entire cohort was 95 ± 1 (95% CI 93-96) months. Higher PROM was associated with reduced survival: A-104 ± 1 (103-105) months, B-96 ± 2 (93-99) months, C-93 ± 3 (88-98) months, D-89 ± 3 (84-94) months, E-74 ± 3 (68-80) months (p < 0.0001). The Area Under the Curve was 0.76 ± 0.02 indicating excellent model discrimination. Independent predictors of long-term mortality included advanced age, lower ejection fraction, reoperation, diabetes mellitus, dialysis and PROM. CONCLUSIONS: The PROM was a reliable predictor of long-term survival in Israeli patients undergoing cardiac surgery. The PROM might be a useful metric for assessing procedural value and surgical decision-making.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgiões , Cirurgia Torácica , Humanos , Israel/epidemiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
7.
Circ Arrhythm Electrophysiol ; 14(2): e009229, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33417475

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a nonthermal energy with potential safety advantages over radiofrequency ablation. This study investigated a novel PFA system-a circular multielectrode catheter (PFA lasso) and a multichannel generator designed to work with Carto 3 mapping system. METHODS: A 7.5F bidirectional circular catheter with 10 electrodes and variable expansion was designed for PFA (biphasic, 1800 Volts). This study included a total of 16 swine used to investigate the following 3 experimental aims: Aim 1 examined the feasibility to create a right atrial ablation line of block from the superior vena cava to the inferior vena cava. Aim 2 examined the effect of PFA on lesion maturation including durability after a 30-day survival period. Aim 3 examined the effect of high-intensity PFA (10 applications) on esophageal and phrenic nerve tissue in comparison to normal intensity radiofrequency ablation (1-2 applications). Histopathologic analysis of all cardiac, esophageal, and phrenic nerve tissue was performed. RESULTS: Acute line of block was achieved in 12/12 swine (100%) and required a total PFA time of 14 seconds (interquartile range [IQR], 9-24.5) per line. Ablation line durability after 28±3 days was maintained in 11/12 (91.7%) swine. PFA resulted in transmural lesions in 179/183 (97.8%) sections and a median lesion width of 14.2 mm. High-intensity PFA (9 [IQR, 8-14] application) had no effect on the esophagus while standard intensity radiofrequency ablation (1.5 [IQR, 1-2] applications) resulted in deep esophageal tissue injury involving the muscularis propria and adventitia layers. High-intensity PFA (16 [IQR, 10-28] applications) has no effect on phrenic nerve function and structure while standard dose radiofrequency ablation (1.5 [IQR, 1-2] applications) resulted in acute phrenic nerve paralysis. CONCLUSIONS: In this preclinical model, a multielectrode circular catheter and multichannel generator produced durable atrial lesions with lower vulnerability to esophageal or phrenic nerve damage.


Assuntos
Arritmias Cardíacas/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Microeletrodos , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Modelos Animais de Doenças , Desenho de Equipamento , Suínos
9.
Ann Thorac Surg ; 111(3): e169-e171, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32771465

RESUMO

This report describes the case of a 43-year-old woman with a right-sided cardiac calcifying fibrous pseudotumor who presented with embolic stroke. This rare clinicopathologic entity should be included in the differential diagnosis of cardiac masses. Tissue diagnosis should be pursued. Management should be tailored to symptoms and feasibility of resection.


Assuntos
Calcinose/diagnóstico , Ecocardiografia Transesofagiana/métodos , AVC Embólico/diagnóstico , Doenças do Mediastino/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Adulto , Calcinose/complicações , Calcinose/cirurgia , Diagnóstico Diferencial , AVC Embólico/etiologia , Feminino , Humanos , Doenças do Mediastino/complicações , Doenças do Mediastino/cirurgia , Procedimentos Cirúrgicos Torácicos/métodos
10.
JACC Clin Electrophysiol ; 6(12): 1499-1506, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33213809

RESUMO

OBJECTIVES: This study sought to evaluate the proportion of patients with atrial fibrillation (AF) who also have undiagnosed sleep apnea and examine the impact of its diagnosis on adherence to sleep apnea therapies. BACKGROUND: Sleep apnea is a modifiable risk factor for AF. However, the proportion of patients with AF who also have undiagnosed sleep apnea and the impact of its diagnosis on therapy have not been well studied. METHODS: This prospective study included 188 consecutive patients with AF without a prior diagnosis of sleep apnea who were scheduled to undergo AF ablation. Participants underwent home sleep apnea testing, completed a sleep apnea screening questionnaire (STOP-BANG [Snoring; Tiredness, Fatigue, or Sleepiness During the Daytime; Observation of Apnea and/or Choking During Sleep; Hypertension; Body Mass Index >35 kg/m2; Age >50 Years; Neck Circumference >40 cm; and Male Sex]) and were followed for ≥2 years to evaluate the impact of diagnosis on therapy. RESULTS: Home sleep apnea testing was positive in 155 of 188 patients (82.4%); among those 155, 127 (82%) had a predominant obstructive component and 28 (18%) had mixed sleep apnea with a 15.2 ± 7.4% central component. Sleep apnea severity was mild in 43.8%, moderate in 32.9%, and severe in 23.2%. The sensitivity and specificity of a STOP-BANG questionnaire were 81.2% and 42.4%, respectively. In a multivariate analysis, STOP-BANG was not predictive for sleep apnea (odds ratio: 0.54; 95% confidence interval: 0.17 to 1.76; p = 0.31). Therapy with continuous positive airway pressure ventilators was initiated in 73 of 85 patients (85.9%) with moderate or severe sleep apnea, and 68 of the 73 patients (93.1%) remained complaint after a mean follow-up period of 21 ± 6.2 months. CONCLUSIONS: Sleep apnea is exceedingly prevalent in patients with AF who are referred for ablation, with a large proportion being undiagnosed due the limited predictive value of sleep apnea symptoms in this AF population. Screening for sleep apnea resulted in high rate of long-term continuous positive airway pressure adherence.


Assuntos
Fibrilação Atrial , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Prevalência , Estudos Prospectivos , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Apneia Obstrutiva do Sono/epidemiologia
11.
JACC Clin Electrophysiol ; 6(11): 1452-1464, 2020 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-33121675

RESUMO

OBJECTIVES: This study sought to investigate the sensitivity of electroanatomical mapping (EAM) to detect scar as identified by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR). BACKGROUND: Previous studies have shown correlation between low voltage electrogram amplitude and myocardial scar. However, voltage amplitude is influenced by the distance between the scar and the mapping surface and its extent. The aim of this study is to examine the reliability of low voltage EAM as a surrogate for myocardial scar using LGE-derived scar as the reference. METHODS: Twelve swine underwent anterior wall infarction by occlusion of the left anterior descending artery (LAD) (n = 6) or inferior wall infarction by occlusion of the left circumflex artery (LCx) (n = 6). Subsequently, animals underwent CMR and EAM using a multielectrode mapping catheter. CMR characteristics, including wall thickness, LGE location and extent, and EAM maps, were independently analyzed, and concordance between voltage maps and CMR characteristics was assessed. RESULTS: LGE volume was similar between the LCx and LAD groups (8.5 ± 2.2 ml vs. 8.3 ± 2.5 ml, respectively; p = 0.852). LGE scarring in the LAD group was more subendocardial, affected a larger surface area, and resulted in significant wall thinning (4.88 ± 0.43 mm). LGE scarring in the LCx group extended from the endocardium to the epicardium with minimal reduction in wall thickness (scarred: 5.4 ± 0.67 mm vs. remote: 6.75 ± 0.38 mm). In all the animals in the LAD group, areas of low voltage corresponded with LGE and wall thinning, whereas only 2 of 6 animals in the LCx group had low voltage areas on EAM. Bipolar and unipolar voltage amplitudes were higher in thick inferior walls in the LCx group than in thin anterior walls in the LAD group, despite a similar LGE volume. CONCLUSIONS: Discordances between LGE-detected scar areas and low voltage areas by EAM highlighted the limitations of the current EAM system to detect scar in thick myocardial wall regions.


Assuntos
Cicatriz , Gadolínio , Animais , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Infarto , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Suínos
12.
JACC Clin Electrophysiol ; 6(8): 973-985, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32819533

RESUMO

OBJECTIVES: The goal of this study was to compare lesion durability between high-power short-duration (HP-SD) and moderate-power moderate-duration (MP-MD) ablation strategies. BACKGROUND: HP-SD radiofrequency ablation (RFA) was developed to improve pulmonary vein isolation (PVI) by reducing the effect of catheter instability inherent to MP-MD ablation strategies. However, its long-term effect on lesion durability for the treatment of atrial fibrillation is unknown. METHODS: Patients with atrial fibrillation (n = 112) underwent PVI using HP-SD ablation (45 to 50 W, 8 to 15 s) with contact force-sensing open irrigated catheter. Cavotricuspid isthmus, mitral annular, and roof lines were permitted. A control group (n = 112) underwent ablation using MP-MD ablation (20 to 40 W, 20 to 30 s) with similar technology. Chronic PV reconnection was examined in patients who required a redo procedure (HP-SD ablation, n = 18; MP-MD ablation, n = 23). RESULTS: The rate of PVI at the completion of the initial encirclement was similar between the HP-SD and MP-MD ablation strategies (90.2% vs. 83.0%; p = 0.006). The HP-SD strategy required shorter RFA time (17.2 ± 3.4 min vs. 31.1 ± 5.6 min; p < 0.001). The incidence of chronic PV reconnection was lower with HP-SD ablation (16.6% vs. 52.2%; p = 0.03). Areas of chronic reconnection were associated with catheter motion ≥1 mm for ≥50% application duration. In a higher proportion of HP-SD applications, catheter motion was <1 mm during ≥50% duration (88.6% vs. 72.8%; p < 0.001), allowing energy delivery with greater stability. Both ablation strategies were effective for cavotricuspid isthmus; however, the HP-SD strategy was less effective for mitral annular lines, requiring ablation at lower power for longer duration to avoid steam pops. CONCLUSIONS: HP-SD ablation may improve PVI durability, and it shortens RFA time. However, ablation in thicker myocardium often requires lower power applied for longer duration, allowing deeper lesions without tissue overheating.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
13.
Circ Arrhythm Electrophysiol ; 13(6): e008580, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32372696

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a nonthermal energy that may provide safety advantages over radiofrequency ablation (RFA). One-shot PFA catheters have been developed for pulmonary vein isolation, but they do not permit flexible lesion sets. This study investigated a novel lattice-tip catheter designed for focal RFA or PFA ablation. METHODS: The effects of PFA (biphasic, 24 amperes) were investigated in 25 swine using a lattice-tip catheter and system (Affera Inc). Step 1 (n=14) examined the feasibility to create atrial line of block and described its acute effects on the phrenic nerve and esophagus. Step 2 (n=7) examined the subacute effects of PFA on block durability, phrenic nerve, and esophagus ≥2 weeks. Step 3 compared the effects of PFA and RFA on the esophagus using a mechanical deviation model approximating the esophagus to the right atrium (n=4) and by direct ablation within its lumen (n=4). The effects of endocardial PFA and RFA on the phrenic nerve were also compared (n=10). Histological analysis was performed. RESULTS: PFA produced acute block in 100% of lines, achieved with 2.1 (1.3-3.2) applications/cm line. Histological analysis following (35 [18-37]) days showed 100% transmurality (thickness range 0.4-3.4 mm) with a lesion width of 19.4 (10.9-27.4 mm). PFA selectively affected cardiomyocytes but spared blood vessels and nervous tissue. PFA applied from the posterior atria (23 [21-25] applications) to the approximated esophagus (6 [4.5-14] mm) produced transmural lesions without esophageal injury. PFA (16.5 [15-18] applications) applied inside the esophageal lumen produced mild edema compared with RFA (13 [12-14] applications) which produced epithelial ulcerations. PFA resulted in no or transient stunning of the phrenic nerve (<5 minutes) without histological changes while RFA produced paralysis. CONCLUSIONS: PFA using a lattice-tip ablation catheter for focal ablation produced durable atrial lesions and showed lower vulnerability to esophageal or phrenic nerve damage compared with RFA.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Eletrodos , Átrios do Coração/cirurgia , Animais , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Esôfago/lesões , Esôfago/patologia , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/patologia , Nervo Frênico/lesões , Nervo Frênico/patologia , Sus scrofa , Fatores de Tempo
14.
Europace ; 22(3): 440-449, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31985784

RESUMO

AIMS: Multielectrode mapping catheters can be advantageous for identifying surviving myocardial bundles in scar. This study aimed to evaluate the utility of a new multielectrode catheter with increased number of small and closely spaced electrodes for mapping ventricles with healed infarction. METHODS AND RESULTS: In 12 swine (four healthy and eight with infarction), the left ventricle was mapped with investigational (OctarayTM) and standard (PentarayTM) multielectrode mapping catheters. The investigational catheter has more electrodes (48 vs. 20), each with a smaller surface area (0.9 vs. 2.0 mm2) and spacing is fixed at 2 mm (vs. 2-6-2 mm). Electrogram (EGM) characteristics, mapping efficiency and scar description were compared between the catheters and late gadolinium enhancement (LGE). Electrogram acquisition rate was faster with the investigational catheter (814 ± 126 vs. 148 ± 58 EGM/min, P = 0.02) resulting in higher density maps (38 ± 10.3 vs. 10.1 ± 10.4 EGM/cm2, P = 0.02). Bipolar voltage amplitude was similar between the catheters in normal and infarcted myocardium (P = 0.265 and P = 0.44) and the infarct surface area was similar between the catheters (P = 0.12) and corresponded to subendocardial LGE. The investigational catheter identified a higher proportion of near-field local abnormal ventricular activities within the low-voltage area (53 ± 16% vs. 34 ± 16%, P = 0.03) that were considered far-field EGMs by the standard catheter. The investigational catheter was also advantageous for mapping haemodymically non-tolerated ventricular tachycardias due to its higher acquisition rate (P < 0.001). CONCLUSION: A novel multielectrode mapping catheter with higher number of small, and closely spaced electrodes increases the mapping speed, EGM density and the ability to recognize low amplitude near-field EGMs in ventricles with healed infarction.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Animais , Catéteres , Cicatriz/patologia , Meios de Contraste , Gadolínio , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/patologia
15.
JACC Clin Electrophysiol ; 6(1): 83-93, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31971910

RESUMO

OBJECTIVES: The goal of this study was to examine the safety and efficacy of radiofrequency ablation (RFA) with irrigated catheters operated in a temperature-controlled mode for ventricular ablation. BACKGROUND: Techniques to increase RFA dimensions are associated with higher risk for steam-pops. A novel irrigated catheter with circumferential thermocouples embedded in its ablation surface provides real-time surface temperature data. This study hypothesized that RFA operated in a temperature-controlled mode may allow maximizing lesion dimensions while reducing the occurrence of steam-pops. METHODS: RFA with an irrigated catheter incorporating surface thermocouples was examined in 6 swine thigh muscle preparations and 15 beating ventricles at higher (50 W/60 s, Tmax50oC) and lower (50 W/60 s, Tmax45oC) temperature limits. Biophysical properties, lesion dimensions, and steam-pop occurrence were compared versus RFA with a standard catheter operated in power-control mode at higher (50 W/60 s) and lower (40W/60 s) power, and additionally at high power with half-normal saline (50 W/60 s). RESULTS: In the thigh muscle preparation, lesion depth and width were similar between all groups (p = 0.90 and p = 0.17, respectively). Steam-pops were most frequent with power-controlled ablation at 50 W/60 s (82%) and least frequent with temperature-controlled ablation at 50 W/60 s, Tmax45oC (0%; p < 0.001). In the beating ventricle, lesion depth was comparable between all RFA settings (p = 0.09). Steam-pops were most frequent using power-controlled ablation at 50 W/60 s (37%) and least frequent with temperature-controlled ablation at 50 W/60 s, Tmax45oC (7%; p < 0.001). Half-normal saline had no incremental effect on lesion dimensions at 50 W in either the thigh muscle or the beating heart. CONCLUSIONS: RFA using a novel irrigated catheter with surface thermocouples operated in a temperature-controlled mode can maximize lesion dimensions while reducing the risk for steam-pops.


Assuntos
Ablação por Cateter , Catéteres , Ventrículos do Coração/cirurgia , Irrigação Terapêutica/instrumentação , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Ablação por Cateter/normas , Desenho de Equipamento , Ventrículos do Coração/patologia , Suínos , Temperatura
17.
Circ Arrhythm Electrophysiol ; 12(11): e007661, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31707809

RESUMO

BACKGROUND: Ventricular tachycardia ablation is often limited by insufficient lesion creation. A novel radiofrequency catheter with an expandable lattice electrode has a larger surface area capable of delivering higher currents at a lower density to potentially increase lesion dimensions without overheating. METHODS: This 8F bidirectional irrigated catheter (Sphere-9, Affera Inc) has a 9 mm spherical lattice tip ("lattice") with an effective surface area 10-fold larger than standard linear catheters. Nine surface thermocouples provide temperature feedback to a proprietary high-current generator operating in a temperature-controlled mode. Ex vivo phase: in 11 bovine hearts, unipolar ablation at 30, 60, and 120 seconds was compared between the lattice (Tmax60°C) and a standard linear irrigated-tip catheter (40 W) at contact force of 10 g. In 5 porcine hearts, bipolar ablation was compared between the catheters (Tmax60°C versus 40 W; 60 seconds). In vivo phase: in 9 swine, ventricular ablation at Tmax60°C versus 40 W was performed for 60 seconds. In addition, direct tissue temperature at 3- and 7-mm tissue depth was measured in a thigh muscle preparation. RESULTS: Ex vivo: lattice produced deeper lesions at 30, 60, and 120 seconds application duration (6.7±1.3 versus 4.8±1.2 mm; 8.3±1.4 versus 5.4±0.8 mm; 10.0±1.6 versus 6.1±1.6 mm, respectively, P≤0.001 for all). Bipolar lesions were deeper (15.8±4.1 versus 10.5±1.4 mm, P<0.001) and more likely to be transmural (80% versus 0%, P=0.002). In vivo: lattice produced deeper lesions (10.5±1.4 versus 6.5±0.8 mm, P≤0.001). Tissue temperature at 7 mm was higher with the lattice (+15.1±2.4°C; P<0.001). The steam-pop occurrence was lower with the lattice (total: 4% versus 18%, P=0.02; in vivo 0% versus 14.2%, P=0.13). CONCLUSIONS: This novel radiofrequency system produces larger ventricular lesions compared with standard irrigated catheters and at a lower risk of tissue overheating. This may improve the efficacy of ventricular tachycardia ablation procedures while reducing the number of applications and procedural duration.


Assuntos
Ablação por Cateter/instrumentação , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca/fisiologia , Taquicardia Ventricular/cirurgia , Irrigação Terapêutica/instrumentação , Animais , Bovinos , Modelos Animais de Doenças , Desenho de Equipamento , Sistema de Condução Cardíaco/fisiopatologia , Suínos , Taquicardia Ventricular/fisiopatologia
18.
Isr Med Assoc J ; 21(10): 671-675, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31599509

RESUMO

BACKGROUND: Recently, Israel established the first national-level adult cardiac surgery database, which was linked to the Society of Thoracic Surgeons (STS). OBJECTIVES: To validate and compare the STS predicted risk of mortality (PROM) to logistic EuroSCORE I (LESI) and EuroSCORE II (ESII) in Israeli patients undergoing cardiac surgery. METHODS: We retrospectively studied 1279 consecutive patients who underwent cardiac surgeries with a calculable PROM. Data were prospectively entered into our database and used to calculate PROM, LESI, and ESII. Scores were normalized and correlated using linear regression and Pearson's test. To examine model calibration, we plotted the total observed versus expected mortality for each score and across five risk-score subgroups. Model discrimination was assessed by measuring the area under the receiver operating curves. RESULTS: The observed 30-day operative mortality was 1.95%. The median (IQ1; IQ3) PROM, LESI, and the ESII scores were 1.45% (0.69; 3.22), 4.54% (2.28; 9.27), and 1.88% (1.18; 3.54), respectively, with observed over expected ratios of 0.63 (95% confidence interval [95%CI] 0.42-0.93), 0.59 (95%CI 0.40-0.87), and 0.24 (95%CI 0.17-0.36), respectively, (STS vs. ESII P = 0.36, STS vs. LESI P = 0.0001). There was good correlation among all scores. All models overestimated mortality. Model discrimination was high and similar for all three scores. Model calibration of the STS, PROM, and ESII were more accurate than the LESI, particularly in higher risk subgroups. CONCLUSIONS: All scores overestimated mortality. In Israeli patients, the STS, PROM, and ESII risk-scores were more reliable metrics than LESI, particularly in higher risk patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Gestão de Riscos/métodos , Gestão de Riscos/estatística & dados numéricos , Idoso , Bases de Dados Factuais , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Índice de Gravidade de Doença , Sociedades Médicas , Cirurgia Torácica
19.
Circ Arrhythm Electrophysiol ; 12(10): e007879, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31597477

RESUMO

BACKGROUND: In infarct-related ventricular tachycardia (VT), the circuit often corresponds to a location characterized by activation slowing during sinus rhythm (SR). However, the relationship between activation slowing during SR and vulnerability for reentry and correlation to components of the VT circuit are unknown. This study examined the relationship between activation slowing during SR and vulnerability for reentry and correlated these areas with components of the circuit. METHODS: In a porcine model of healed infarction, the spatial distribution of endocardial activation velocity was compared between SR and VT. Isthmus sites were defined using activation and entrainment mapping as areas exhibiting diastolic activity within the circuit while bystanders were defined as areas displaying diastolic activity outside the circuit. RESULTS: Of 15 swine, 9 had inducible VT (5.2±3.0 per animal) while in 6 swine VT could not be induced despite stimulation from 4 RV and LV sites at 2 drive trains with 6 extra-stimuli down to refractoriness. Infarcts with VT had a greater magnitude of activation slowing during SR. A minimal endocardial activation velocity cutoff ≤0.1 m/s differentiated inducible from noninducible infarctions (P=0.015). Regions of maximal endocardial slowing during SR corresponded to the VT isthmus (area under curve=0.84 95% CI, 0.78-0.90) while bystander sites exhibited near-normal activation during SR. VT circuits were complex with 41.7% exhibiting discontinuous propagation with intramural bridges of slow conduction and delayed quasi-simultaneous endocardial activation. Regions forming the VT isthmus borders had faster activation during SR while regions forming the inner isthmus were activated faster during VT. CONCLUSIONS: Endocardial activation slowing during SR may differentiate infarctions vulnerable for VT from those less vulnerable for VT. Sites of slow activation during SR correspond to sites forming the VT isthmus but not to bystander sites.


Assuntos
Cicatriz/fisiopatologia , Endocárdio/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Taquicardia Ventricular/etiologia , Animais , Mapeamento Potencial de Superfície Corporal/métodos , Modelos Animais de Doenças , Ventrículos do Coração/fisiopatologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia
20.
JACC Clin Electrophysiol ; 5(8): 920-931, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31439293

RESUMO

OBJECTIVES: This study sought to characterize the histopathological features of radiofrequency ablation (RFA) in heterogeneous ventricular scar in comparison to those in healthy myocardium. BACKGROUND: The histopathological features of RFA have been studied largely in normal myocardium. However, its effect on clinically relevant heterogeneous scar is not well understood. METHODS: Five swine with chronic infarction underwent RFA using 35-W, 45-s, 10-20 g (Biosense Webster, Irwindale, California) in heterogenous scar tissue (voltage ≤1.5 mV) and healthy myocardium (≥3.0 mV). The location of each application was marked using the electroanatomical mapping system. Histological sections at intervals of 0.5 mm with hematoxylin and eosin and Masson's trichrome stained intervals were created. A pathologist blinded to the myocardium type characterized the extent of RF injury in cellular, extracellular, and vascular structures. RESULTS: In healthy myocardium, 23 of 23 lesions (100%) were well demarcated and could be precisely measured (width: 11.3 ± 3.3 mm; depth: 7.3 ± 2.0 mm). In scar tissue, only 3 of 30 lesions (10%) were identified, and none could be measured due to a lack of defined borders. Lesions in healthy myocardium had a distinctive architecture showing a coagulative necrosis core surrounded by an outer rim of contraction band necrosis. Lesions in scar had ill-defined tissue injury without a distinct architecture. In all ablated regions, viable myocytes remained interspersed between necrotic myocytes exhibiting characteristics of both coagulative and contraction band necrosis. Connective tissue was more resistant to thermal injury in comparison to cardiomyocytes. CONCLUSIONS: RFA in scarred myocardium results in irregular tissue injury and unpredictable effect on surviving cardiomyocytes. This may be related to biophysical differences between healthy and scarred myocardium.


Assuntos
Ablação por Cateter , Cicatriz/patologia , Ventrículos do Coração , Animais , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Masculino , Infarto do Miocárdio/patologia , Infarto do Miocárdio/cirurgia , Miocárdio/patologia , Suínos , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...