Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Angiol ; 32(1): 48-55, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36727154

RESUMO

Paclitaxel drug-coated balloons (DCB) have been shown to reduce target lesion revascularization (TLR) rate, but recently an association between paclitaxel and an increase in mortality at 5-year was reported. We reviewed the 5-year mortality and freedom from TLR rates from a single center among patients that received DCB. Consecutive patients that received DCB from July 8, 2015 to November 27, 2019 with follow-up obtained from medical records and review of official death certificates were reviewed. The primary objective was total mortality and TLR rates with cumulative exposure to paclitaxel-coated balloons. Demographic, angiographic, clinical, and procedural variables were collected. Causes of mortality were classified according to death certificates. Descriptive analysis was performed on all variables. Kruskal-Wallis test was used to compare the total length of DCBs in those who were alive and those who died by the end of study. Kaplan-Meier (KM) was used to plot the freedom from mortality up to 5 years. A total of 91 symptomatic patients received the Lutonix balloon at index to treat femoropopliteal arterial disease and subsequently received either Lutonix or in.PACT during the follow-up phase for additional procedures. Age was 68.4 ± 10.8 years (56.0% males). Critical limb ischemia was present in 20.9%. There was no statistical difference in mortality between the median total number of balloons used among patients who were alive versus those who died (2.5 vs. 3.0, p -value = 0.89). Also, there was no statistical difference in the total length of DCB balloons used between those who were alive and those who died at the end of the study (p-value = 0.39). There were no in-hospital amputation or death. At 5-year follow-up KM freedom from TLR was 78.5%. A total of 13 patients died during follow-up. Of these 10 received only the Lutonix balloon and 3 did receive both Lutonix and In.PACT. The yearly KM freedom from mortality for the Lutonix only cohort were 92.7, 89.1, 85.5, 83.6, and 81.8% at 1, 2, 3, 4, and 5 years, respectively. Freedom from TLR and mortality at 5 years appears to be favorable with the use of DCB, predominantly Lutonix balloon in this cohort. This data needs to be supported prospectively by a larger number of patients.

2.
Cardiovasc Revasc Med ; 21(1): 96-99, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30503038

RESUMO

BACKGROUND: The WIRION EPS filter was recently approved by the Food and Drug Administration (FDA) to be used in conjunction with all atherectomy devices when treating infrainguinal peripheral arterial disease. The safety of this filter with Jetstream atherectomy (JA) in a real world setting remains unclear. METHODS: Consecutive patients from the practice of one operator who underwent JA under WIRION EPS when treating femoropopliteal arteries were enrolled in this retrospective analysis. The primary safety endpoint was the ability of the filter to capture macrodebris with no dissection or thrombosis at the filter site and no filter-related major adverse events. Descriptive analysis on demographics, clinical, procedural and angiographic variables was done using mean ±â€¯SD for continuous variables and percentages for categorical variables. RESULTS: 37 patients were enrolled in this study between June 2016 and September of 2018 (64.9% males, age 68.7 ±â€¯9.0, BMI 27.7 ±â€¯5.4). TASC II classification of the treated lesions were 51.4% B, 24.3% A, 21.6% C, and 2.7% D. At the filter site, spasm occurred in 1/37 (2.7%), while dissection did not occur (0%). Embolization within the filter was found in 51.4% of patients: 14/37 (37.8%) macro debris and 5/35 (13.5%) micro debris. Clinically significant embolization distal to the filter that required treatment with more than a simple aspiration was 1/37 (2.7%). CONCLUSION: WIRION EPS filter use with Jetstream atherectomy was safe and was associated with a low rate of significant distal embolization that required more than a simple aspiration to treat.


Assuntos
Aterectomia/instrumentação , Dispositivos de Proteção Embólica , Embolia/prevenção & controle , Artéria Femoral , Doença Arterial Periférica/terapia , Artéria Poplítea , Idoso , Aterectomia/efeitos adversos , Embolia/etiologia , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Iowa , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...