Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Indian Prosthodont Soc ; 19(1): 66-73, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30745756

RESUMO

AIM: Aim of the current study was to evaluate the effect of occlusal jig with increased vertical dimension and mandibular advancement device on the oropharangeal volume in completely edentulous patients using spirometry and cephalometry. MATERIALS AND METHODS: The current study included includes 30 completely edentulous patient according to inclusion criteria. They were each subjected to cephalometric and spirometric analysis wearing CCD, OJ & MAD. Results obtained were subjected to following statistical analysis, one-way ANOVA test, unpaired t-test, and Dunnett's test. RESULT: Both OJ & MAD brings about significant change in oropharangeal volume hence both the devices are effective treatment of choice for OSA, while greater increase was observed in oropharangealvolume of OJ as compared to MAD. Spirometric analysis shows insignificant changes in the oropharangeal volume caused by MAD while OJ causes small but significant change in oropharangeal volume (PIFR]. CONCLUSION: Within the limitation of the study, it can be concluded that, on cephalometric & spirometric evaluation, OJ shows greater increase in oropharangeal volume when compared to MAD in completely edentulous patient.

2.
J Chromatogr Sci ; 48(10): 830-4, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21044414

RESUMO

The present study relates to a new capillary electrophoresis method for the determination of N-methylpyrrolidine, an impurity considered to be toxic and also potential degradation impurity in cefepime hydrochloride drug substance. The newly developed capillary electrophoresis method for determining the content of N-methylpyrrolidine in cefepime for injection has been validated as per International Conference on Harmonization (ICH) guidelines to prove the selectivity, sensitivity, suitability, robustness, and ruggedness of the method. This simple, efficient, and rapid methodology may be used by pharmaceutical industry for routine analysis as well as during stability studies. The newly developed capillary electrophoresis method to determine the content of N-methylpyrrolidine in cefepime for injection requires 10 min for data acquisition, and uses an indirect UV photometry method to detect the analyte signal at 240 nm against the reference signal at 210 nm. The electrophoretic system is optimized to get stable base line, higher signal to noise ratio and peaks with narrow peak width. The method employs bare fused silica capillary with extended light path, effective length of capillary is 56 cm and inner diameter of capillary is 50 µm, 5 mmole of imidazole buffer adjusted to pH 5.1 with 3 molar acetic acid solution is used as background electrolyte. The sample is introduced in hydrodynamic mode employing pressure of 50 mbar for 5 s, and the desired separation is achieved with constant applied voltage of 25 kV at ambient temperature (~25°C).


Assuntos
Cefalosporinas/análise , Eletroforese Capilar/métodos , Pirrolidinas/análise , Cefepima , Contaminação de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...