1.
J Biomed Mater Res B Appl Biomater ; 104(5): 941-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-25976358

RESUMO

Obstruction of fluid flow by stationary bubbles in a microchannel hemodialyzer decreases filtration performance and increases damage to blood cells through flow maldistribution. A polyethylene oxide (PEO)-polybutadiene (PB)-polyethylene oxide surface modification, previously shown to reduce protein fouling and water/air contact angle in polycarbonate microchannel hemodialyzers, can improve microchannel wettability and may reduce bubble stagnation by lessening the resistive forces that compete with fluid flow. In this study, the effect of the PEO-PB-PEO coating on bubble retention in a microchannel array was investigated. Polycarbonate microchannel surfaces were coated with PEO-PB-PEO triblock polymer via radiolytic grafting. Channel obstruction was measured for coated and uncoated microchannels after injecting a short stream of air bubbles into the device under average nominal water velocities of 0.9 to 7.2 cm/s in the channels. The presence of the PEO coating reduced obstruction of microchannels by stationary bubbles within the range of 1.8 to 3.6 cm/s, average nominal velocity. Numerical simulations based on the lattice Boltzmann method indicate that beneficial effects may be due to the maintenance of a lubricating, thin liquid film around the bubble. The determined effective range of the PEO coating for bubble management serves as an important design constraint. These findings serve to validate the multiutility of the PEO-PB-PEO coating (bubble lubrication, biocompatibility, and therapeutic loading). © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 941-948, 2016.


Assuntos
Butadienos/química , Materiais Revestidos Biocompatíveis/química , Elastômeros/química , Cimento de Policarboxilato/química , Polietilenoglicóis/química , Diálise Renal , Propriedades de Superfície
2.
J Fluids Eng ; 137(3): 0312081-312087, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25729115

RESUMO

This paper highlights the influence of contact line (pinning) forces on the mobility of dry bubbles in microchannels. Bubbles moving at velocities less than the dewetting velocity of liquid on the surface are essentially dry, meaning that there is no thin liquid film around the bubbles. For these "dry" bubbles, contact line forces and a possible capillary pressure gradient induced by pinning act on the bubbles and resist motion. Without sufficient driving force (e.g., external pressure), a dry bubble is brought to stagnation. For the first time, a bipartite theoretical model that estimates the required pressure difference across the length of stagnant bubbles with concave and convex back interfaces to overcome the contact line forces and stimulate motion is proposed. To validate our theory, the pressure required to move a single dry bubble in square microchannels exhibiting contact angle hysteresis has been measured. The working fluid was deionized water. The experiments have been conducted on coated glass channels with different surface hydrophilicities that resulted in concave and convex back interfaces for the bubbles. The experimental results were in agreement with the model's predictions for square channels. The predictions of the concave and convex back models were within 19% and 27% of the experimental measurements, respectively.

3.
J Fluids Eng ; 135(2): 212021-2120210, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23917622

RESUMO

Experimental studies employing advanced measurement techniques have played an important role in the advancement of two-phase microfluidic systems. In particular, flow visualization is very helpful in understanding the physics of two-phase phenomenon in microdevices. The objective of this article is to provide a brief but inclusive review of the available methods for studying bubble dynamics in microchannels and to introduce prior studies, which developed these techniques or utilized them for a particular microchannel application. The majority of experimental techniques used for characterizing two-phase flow in microchannels employs high-speed imaging and requires direct optical access to the flow. Such methods include conventional brightfield microscopy, fluorescent microscopy, confocal scanning laser microscopy, and micro particle image velocimetry (micro-PIV). The application of these methods, as well as magnetic resonance imaging (MRI) and some novel techniques employing nonintrusive sensors, to multiphase microfluidic systems is presented in this review.

4.
Lab Chip ; 11(14): 2319-24, 2011 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-21709881

RESUMO

Three-dimensional (3D) continuous microparticle focusing has been achieved in a single-layer polydimethylsiloxane (PDMS) microfluidic channel using a standing surface acoustic wave (SSAW). The SSAW was generated by the interference of two identical surface acoustic waves (SAWs) created by two parallel interdigital transducers (IDTs) on a piezoelectric substrate with a microchannel precisely bonded between them. To understand the working principle of the SSAW-based 3D focusing and investigate the position of the focal point, we computed longitudinal waves, generated by the SAWs and radiated into the fluid media from opposite sides of the microchannel, and the resultant pressure and velocity fields due to the interference and reflection of the longitudinal waves. Simulation results predict the existence of a focusing point which is in good agreement with our experimental observations. Compared with other 3D focusing techniques, this method is non-invasive, robust, energy-efficient, easy to implement, and applicable to nearly all types of microparticles.


Assuntos
Acústica , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Modelos Teóricos , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS