Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Front Chem ; 10: 976635, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36092655

RESUMO

Flerovium (Fl, element 114) is the heaviest element chemically studied so far. To date, its interaction with gold was investigated in two gas-solid chromatography experiments, which reported two different types of interaction, however, each based on the level of a few registered atoms only. Whereas noble-gas-like properties were suggested from the first experiment, the second one pointed at a volatile-metal-like character. Here, we present further experimental data on adsorption studies of Fl on silicon oxide and gold surfaces, accounting for the inhomogeneous nature of the surface, as it was used in the experiment and analyzed as part of the reported studies. We confirm that Fl is highly volatile and the least reactive member of group 14. Our experimental observations suggest that Fl exhibits lower reactivity towards Au than the volatile metal Hg, but higher reactivity than the noble gas Rn.

2.
Phys Rev Lett ; 123(16): 165001, 2019 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-31702328

RESUMO

Neutron spectra from secondary ^{3}H(d,n)α reactions produced by an implosion of a deuterium-gas capsule at the National Ignition Facility have been measured with order-of-magnitude improvements in statistics and resolution over past experiments. These new data and their sensitivity to the energy loss of fast tritons emitted from thermal ^{2}H(d,p)^{3}H reactions enable the first statistically significant investigation of charged-particle stopping via the emitted neutron spectrum. Radiation-hydrodynamic simulations, constrained to match a number of observables from the implosion, were used to predict the neutron spectra while employing two different energy loss models. This analysis represents the first test of stopping models under inertial confinement fusion conditions, covering plasma temperatures of k_{B}T≈1-4 keV and particle densities of n≈(12-2)×10^{24} cm^{-3}. Under these conditions, we find significant deviations of our data from a theory employing classical collisions whereas the theory including quantum diffraction agrees with our data.

3.
Appl Radiat Isot ; 143: 163-175, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30447627

RESUMO

Nuclear fusion experiments performed at the National Ignition Facility produce radioactive debris, arising in reactions of fast neutrons with the target assembly. We have found that postshot debris collections are fractionated, such that isotope ratios in an individual debris sample may not be representative of the radionuclide inventory produced by the experiment. We discuss the potential sources of this fractionation and apply isotope-correlation techniques to calculate unfractionated isotope ratios that are used in measurements of nuclear reaction cross sections.

4.
Rev Sci Instrum ; 89(10): 10I133, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399665

RESUMO

A large area solid radiochemistry collector was deployed at the National Ignition Facility (NIF) with a collection efficiency for post-shot, solid target debris of approximately 1% of the total 4π solid angle. The collector consisted of a 20-cm diameter vanadium foil surrounded by an aluminum side-enclosure and was fielded 50 cm from the NIF target. The collector was used on two NIF neutron yield shots, both of which had a monolayer of 238U embedded in the capsule ablator 10 µm from the inner surface. Fission and activation products produced in the 238U were collected, and subsequent analyses via gamma spectroscopy indicated that the distribution of fission products was not uniform, with peak and valley fission products preferentially collected on the vanadium and low- and high-mass fission products primarily located on the aluminum side-enclosure. The results from these shots will be used to design future nuclear data experiments at NIF.

5.
JRSM Open ; 9(9): 2054270418793021, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30202534

RESUMO

OBJECTIVES: The treatments of limbic and other autoimmune encephalitis include immunosuppression, symptomatic treatment, and in the case of paraneoplastic syndromes, appropriate therapy for underlying neoplasms. When immunotherapy is considered, intravenous immunoglobulin is one option for treatment, either alone or in combination with corticosteroids. To date, however, evidence for the use of intravenous immunoglobulin in this context comes from case series/expert reviews as no controlled trials have been performed. We aimed to analyse the NHS England Database of intravenous immunoglobulin usage, which was designed to log use and guide procurement, to explore usage and therapeutic effect of intravenous immunoglobulin in autoimmune encephalitis in England. DESIGN: We conducted a retrospective audit and review of the NHS England Database on intravenous immunoglobulin use. SETTING: NHS England Database of intravenous immunoglobulin use which covers secondary and tertiary care prescribing and use of intravenous immunoglobulin for all patients in hospitals in England. PARTICIPANTS: Hospital in-patients with confirmed or suspected autoimmune/limbic encephalitis between September 2010 and January 2017. RESULTS: A total of 625 patients who were 18 years of age or older were treated with intravenous immunoglobulin for autoimmune encephalitis, of whom 398 were determined as having 'highly likely' or 'definite' autoimmune/limbic encephalitis. Ninety-six percent were treated with a single course of intravenous immunoglobulin. The availability and accuracy of reporting of outcomes was very poor, with complete data only available in 27% of all cases. CONCLUSIONS: This is the first review of data from this unique national database. Whilst there was evidence for clinical improvement in many cases of patients treated with intravenous immunoglobulin, the quality of outcome data was generally inadequate. Methods to improve quality, accuracy and completeness of reporting are crucial to maximise the potential value of this resource as an auditing tool.

6.
Rev Sci Instrum ; 87(11): 11D813, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910632

RESUMO

The solid debris collection capability at the National Ignition Facility has been expanded to include a third line-of-sight assembly. The solid radiochemistry nuclear diagnostic measurement of the ratio of gold isotopes is dependent on the efficient collection of neutron-activated hohlraum debris by passive metal disks. The collection of target debris at this new location is more reliable in comparison to the historic locations, and it appears to be independent of collector surface ablation.

7.
Rev Sci Instrum ; 87(11): 11D838, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910394

RESUMO

Precisely-known fission yield distributions are needed to determine a fissioning isotope and the incident neutron energy in nuclear security applications. 14 MeV neutrons from DT fusion at the National Ignition Facility induce fission in depleted uranium contained in the target assembly hohlraum. The fission yields of Kr isotopes (85m, 87, 88, and 89) are measured relative to the cumulative yield of 88Kr and compared to previously tabulated values. The results from this experiment and England and Rider are in agreement, except for the 85mKr/88Kr ratio, which may be the result of incorrect nuclear data.

8.
Appl Radiat Isot ; 107: 199-202, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26524406

RESUMO

A high-purity carrier-free (7)Be was efficiently isolated following proton bombardment of a lithium hydroxide-aluminum target. The separation of beryllium from lithium and aluminum was achieved through a hydrochloric acid elution system utilizing cation exchange chromatography. The beryllium recovery, +99%, was assessed through gamma spectroscopy while the chemical purity was established by mass spectrometry. The decontamination factors of beryllium from lithium and aluminum were determined to be 6900 and 300, respectively.

9.
Rev Sci Instrum ; 86(7): 076105, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233419

RESUMO

A new radiochemical method for determining deuterium-tritium (DT) fuel and plastic ablator (CH) areal densities (ρR) in high-convergence, cryogenic inertial confinement fusion implosions at the National Ignition Facility is described. It is based on measuring the (198)Au/(196)Au activation ratio using the collected post-shot debris of the Au hohlraum. The Au ratio combined with the independently measured neutron down scatter ratio uniquely determines the areal densities ρR(DT) and ρR(CH) during burn in the context of a simple 1-dimensional capsule model. The results show larger than expected ρR(CH) values, hinting at the presence of cold fuel-ablator mix.

10.
Rev Sci Instrum ; 85(6): 063508, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985820

RESUMO

We describe a radiochemical measurement of the ratio of isotope concentrations produced in a gold hohlraum surrounding an Inertial Confinement Fusion capsule at the National Ignition Facility (NIF). We relate the ratio of the concentrations of (n,γ) and (n,2n) products in the gold hohlraum matrix to the down-scatter of neutrons in the compressed fuel and, consequently, to the fuel's areal density. The observed ratio of the concentrations of (198m+g)Au and (196g)Au is a performance signature of ablator areal density and the fuel assembly confinement time. We identify the measurement of nuclear cross sections of astrophysical importance as a potential application of the neutrons generated at the NIF.

11.
Phys Rev Lett ; 109(16): 162501, 2012 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-23215070

RESUMO

Two years after the discovery of element 117, we undertook a second campaign using the (249)Bk+(48)Ca reaction for further investigations of the production and decay properties of the isotopes of element 117 on a larger number of events. The experiments were started in the end of April 2012 and are still under way. This Letter presents the results obtained in 1200 hours of an experimental run with the beam dose of (48)Ca of about 1.5×10(19) particles. The (249)Bk target was irradiated at two energies of (48)Ca that correspond to the maximum probability of the reaction channels with evaporation of three and four neutrons from the excited (297)117. In this experiment, two decay chains of (294)117 (3n) and five decay chains of (293)117 (4n) were detected. In the course of the long-term work, (249)Cf-the product of decay of (249)Bk (330 d)-is being accumulated in the target. Consequently, in the present experiment, we also detected a single decay of the known isotope (294)118 that was produced during 2002-2005 in the reaction (249)Cf((48)Ca,3n)(294)118. The obtained results are compared with the data from previous experiments. The experiments are carried out in the Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, using the heavy-ion cyclotron U400.

12.
Rev Sci Instrum ; 83(10): 10D904, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126908

RESUMO

Radiochemical analysis of post-ignition debris inside the National Ignition Facility (NIF) target chamber can help determine various diagnostic parameters associated with the implosion efficiency of the fusion capsule. This technique is limited by the ability to distinguish ablator material from other debris and by the collection efficiency of the capsule debris after implosion. Prior to designing an on-line collection system, the chemical nature and distribution of the debris inside the chamber must be determined. The focus of our current work has been on evaluating capture of activated Au hohlraum debris on passive foils (5 cm diameter, 50 cm from target center) post-shot. Preliminary data suggest that debris distribution is locally heterogeneous along the equatorial and polar line-of-sights.

13.
Rev Sci Instrum ; 83(10): 10D917, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126919

RESUMO

The Radiochemical Analysis of Gaseous Samples (RAGS) diagnostic apparatus was recently installed at the National Ignition Facility (NIF). Following a NIF shot, RAGS is used to pump the gas load from the NIF chamber for purification and isolation of the noble gases. After collection, the activated gaseous species are counted via gamma spectroscopy for measurement of the capsule areal density and fuel-ablator mix. Collection efficiency was determined by injecting a known amount of (135)Xe into the NIF chamber, which was then collected with RAGS. Commissioning was performed with an exploding pusher capsule filled with isotopically enriched (124)Xe and (126)Xe added to the DT gas fill. Activated xenon species were recovered post-shot and counted via gamma spectroscopy. Results from the collection and commissioning tests are presented. The performance of RAGS allows us to establish a noble gas collection method for measurement of noble gas species produced via neutron and charged particle reactions in a NIF capsule.

14.
Phys Rev Lett ; 108(2): 022502, 2012 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-22324675

RESUMO

Results of a new series of experiments on the study of production cross sections and decay properties of the isotopes of element 115 in the reaction (243)Am+(48)Ca are presented. Twenty-one new decay chains originating from (288)115 were established as the product of the 3n-evaporation channel by measuring the excitation function at three excitation energies of the compound nucleus (291)115. The decay properties of all newly observed nuclei are in full agreement with those we measured in 2003. At the lowest excitation energy E*=33 MeV, for the first time we registered the product of the 2n-evaporation channel, (289)115, which was also observed previously in the reaction (249)Bk+(48)Ca as the daughter nucleus of the decay of (293)117. The maximum cross section for the production of (288)115 is found to be 8.5 pb at E*≈36 MeV.

15.
Haemophilia ; 17(3): 456-62, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21371184

RESUMO

Factor VIII (FVIII) concentrates have revolutionized the treatment of patients with haemophilia A. Concerns over the transmission of viral infections through these products have been addressed through stringent, donor-screening procedures and robust antiviral manufacturing steps. Bio Products Laboratory has developed a high-purity FVIII product with von Willebrand factor, Optivate(®). Its safety, tolerability and efficacy as prophylaxis and treatment of bleeds have been established in long-term studies. Seventy previously treated patients with severe haemophilia A, with ≥ 20 exposure days, were recruited into two long-term, multicentre, open-label studies. The protocols were virtually identical. Patients received Optivate(®) either prophylactically or on-demand. A mean of 159.0 EDs were experienced over 11,320 infusions. Under both conditions, Optivate(®) was well tolerated. Only 10% of patients experienced a treatment-related adverse event; the most commonly reported were headache (4% of patients) and dizziness (3% of patients). The mean number of bleeds/patient over the 2 year treatment period was 23.5 during prophylactic use and 70.4 during on-demand use. In patients treated prophylactically, clinical responses to breakthrough bleeds were rated by physicians as excellent or good and as very helpful or helpful by patients in 95% of bleeds. Clinical responses for on-demand patients were rated as excellent or good by physicians and helpful or very helpful by the patients for 91% of bleeds. There were no viral transmissions or inhibitors. The studies confirm the clinical efficacy and safety of Optivate(®) in both prophylactic and on-demand management of patients with haemophilia A.


Assuntos
Fator VIII/uso terapêutico , Hemofilia A/tratamento farmacológico , Hemorragia/tratamento farmacológico , Hemostáticos/uso terapêutico , Fator de von Willebrand/uso terapêutico , Adolescente , Adulto , Idoso , Criança , Combinação de Medicamentos , Fator VIII/administração & dosagem , Fator VIII/efeitos adversos , Hemorragia/prevenção & controle , Hemostáticos/administração & dosagem , Hemostáticos/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Adulto Jovem , Fator de von Willebrand/administração & dosagem , Fator de von Willebrand/efeitos adversos
16.
Phys Rev Lett ; 104(14): 142502, 2010 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-20481935

RESUMO

The discovery of a new chemical element with atomic number Z=117 is reported. The isotopes (293)117 and (294)117 were produced in fusion reactions between (48)Ca and (249)Bk. Decay chains involving 11 new nuclei were identified by means of the Dubna gas-filled recoil separator. The measured decay properties show a strong rise of stability for heavier isotopes with Z > or = 111, validating the concept of the long sought island of enhanced stability for superheavy nuclei.

17.
Thromb Haemost ; 103(2): 338-43, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20024496

RESUMO

Venous thromboembolism (VTE) is a clinically important complication for both hospitalised and ambulatory cancer patients. In the current study, the frequency, demographics and risk (according to tumour site) of VTE were examined among patients seen at outpatient DVT (deep-vein thrombosis) clinics. Of 10,015 VTE cases, 1,361 were diagnosed with cancer, for an overall rate of cancer-associated VTE of 13.6% in this outpatient population. Patients with cancer-associated VTE were significantly older than cancer-free VTE cases (66.4 +/- 12.7 vs. 58.8 +/- 18.5 years; p<0.0001). The frequency of cancer-associated VTE peaked earlier among females than males, occurring in the sixth (137/639, 21.4% vs. 98/851, 11.3%; p<0.001) and seventh decades (213/980, 21.7% vs. 197/1096, 18%; p=0.036). VTE was described most frequently in common cancers - breast, prostate, colorectal and lung (56.1% of cases). The risk of VTE varied widely across 17 cancer types. Calculating odds ratios (OR) to assess the effect size of cancer type on VTE risk, the highest odds were observed for patients with pancreatic cancer (OR 9.65, 95% confidence interval [CI] (5.51-16.91). Tumours of the head and neck had higher odds than previously reported (OR 8.24, 95% CI 5.06-13.42). Reduced risk estimates were observed for skin cancers (melanoma and non-melanoma: OR 0.89, 95% CI 0.42-1.87; OR 0.74, 95% CI, 0.32-1.69, respectively). We conclude that outpatients have a similar rate of cancer-associated VTE as VTE patient populations previously reported, that cancer-associated VTE occurs in an older age group and earlier in females and that outpatients exhibit distinct tumour site-specific risk from that described among hospitalised cancer patients.


Assuntos
Instituições de Assistência Ambulatorial , Neoplasias/epidemiologia , Tromboembolia Venosa/epidemiologia , Adolescente , Adulto , Distribuição por Idade , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Neoplasias/classificação , Neoplasias/complicações , Razão de Chances , Fatores de Risco , Fatores Sexuais , Tromboembolia Venosa/etiologia , Trombose Venosa , Adulto Jovem
18.
Rev Sci Instrum ; 79(10): 10E503, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044489

RESUMO

Understanding mix in inertial confinement fusion (ICF) experiments at the National Ignition Facility requires the diagnosis of charged-particle reactions within an imploded target. Radiochemical diagnostics of these reactions are currently under study by scientists at Los Alamos and Lawrence Livermore National Laboratories. Measurement of these reactions requires assay of activated debris and tracer gases from the target. Presented below is an overview of the prompt radiochemistry diagnostic development efforts, including a discussion of the reactions of interest as well as the progress being made to collect and count activated material.

19.
Br J Anaesth ; 95(5): 596-602, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16183679

RESUMO

BACKGROUND: Receiving an allogeneic transfusion may be an independent predictor of mortality for patients undergoing cardiac surgery. Furthermore, these patients utilize 15% of all donated blood in the UK. In our unit, 80% of patients undergoing complex non-coronary cardiac surgery requiring cardiopulmonary bypass (CPB) receive an allogeneic transfusion. Activated recombinant FVII (rFVIIa) may be effective in reducing this need for transfusion. METHODS: Twenty patients undergoing complex cardiac surgery were randomized to receive rFVIIa or placebo after CPB and reversal of heparin. RESULTS: Two patients in the rFVIIa group received 13 units of allogeneic red cells and coagulation products compared with eight patients receiving 105 units of allogeneic red cells and coagulation products in the placebo group (relative risk of any transfusion 0.26; confidence interval 0.07-0.9; P=0.037). The groups did not differ for adverse events. CONCLUSION: Despite major limitations (underpowered study and prone to type I error), we have shown that rFVIIa significantly reduces the need for allogeneic transfusion in complex non-coronary cardiac surgery without causing adverse events.


Assuntos
Transfusão de Sangue , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Fator VIIa/uso terapêutico , Hemostáticos/uso terapêutico , Idoso , Coagulação Sanguínea/efeitos dos fármacos , Método Duplo-Cego , Hemoglobinas/metabolismo , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Cuidados Pós-Operatórios/métodos , Hemorragia Pós-Operatória/prevenção & controle , Hemorragia Pós-Operatória/terapia , Proteínas Recombinantes/uso terapêutico , Tromboelastografia
20.
Environ Sci Technol ; 39(8): 2608-15, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15884356

RESUMO

Manganese oxides, present as minor phases in the vadose zone, have been previously shown to sequester large quantities of plutonium under environmental conditions. We are now continuing these studies with Np(V). Sorption onto manganite (MnOOH) and hausmannite (Mn3O4) at solid-to-solution ratios of 2.5-3.3 mg/mL has been studied as a function of neptunium concentration and pH. The sorption of Np increased as a function of pH for both minerals, attaining a maximum at neutral pH, and then decreased with increasing alkalinity. X-ray absorption fine structure spectroscopy (XAFS), taken at the Np L(III)-edge, has been used to determine the oxidation state of the sorbed Np. Our experimental results indicate reduction of the Np(V) because of interaction with the X-ray beam. These findings significantly impact the interpretation of results reported elsewhere on Np(V) investigated though the use of high-intensity X-ray beams.


Assuntos
Poluentes Ambientais , Compostos de Manganês/química , Netúnio/química , Óxidos/química , Interações Medicamentosas , Concentração de Íons de Hidrogênio , Espectroscopia de Ressonância Magnética , Minerais/química , Espectrometria por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...