Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Otol Rhinol Laryngol ; 133(6): 575-580, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38491865

RESUMO

OBJECTIVE: Creation of a novel 3D-printed physical cochlear model that demonstrated the feasibility of creating the model, and impact of a Graphical User Interface (GUI) system on training insertion metrics. STUDY DESIGN: Feasibility study with a pilot prospective data collection. SETTING: Tertiary academic center. METHODS: The study was IRB exempt. Five resident trainees (PGY1-PGY5) practiced electrode insertions in cadaveric temporal bones before using the simulator. Nine students were educated on how to hold the electrodes and position them, and then allowed to use the simulator. All trainees were instructed that slower insertions were favorable. One cochlear implant (CI) surgeon used the simulator. The GUI captured the real video feed, but also provided distance, trajectory, and velocity measurements. The program is designed to plot the real-time depth of insertion and speed of insertion of the electrode; the user is also provided real-time occurrence of any kinks and back-outs. RESULTS: A total of 14 trainees and 1 CI surgeon inserted the electrode at least 5 times without the use of the GUI (before) and then at least 5 times with the use of the GUI (after). Average Speed before and after (100.84 and 53.23 mm/s); Average minimum speed before and after (59.34 and 9.65 mm/s); and Average maximum speed before and after (416 and 285.81 mm/s). Statistically significant improvements were noted in all the measured speeds of insertion (P < .001). The other variables improved but not to a statistical significance. CONCLUSIONS: Real-time training using the 3D-printed model and GUI for cochlear implantation can help improve surgical resident training and comfort levels with electrode insertion for surgical trainees. The advantage of this model is that surgeons/trainees can use it as many times as they like, as the whole set-up is easy, economical, and reusable. The real time graphical user interface enhances training and retention of the practiced skills.


Assuntos
Implante Coclear , Estudos de Viabilidade , Internato e Residência , Modelos Anatômicos , Impressão Tridimensional , Humanos , Implante Coclear/educação , Implante Coclear/métodos , Internato e Residência/métodos , Estudos Prospectivos , Projetos Piloto , Treinamento por Simulação/métodos , Competência Clínica , Cadáver , Interface Usuário-Computador , Osso Temporal/cirurgia , Implantes Cocleares , Cóclea/cirurgia , Otolaringologia/educação
2.
Cureus ; 15(2): e35559, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37007334

RESUMO

We present an uncommon case of a pediatric patient with sudden-onset sensorineural hearing loss (SSNHL), a medical condition in which a person experiences a rapid loss of 30 or more decibels within a matter of hours or days. The patient is a nine-year-old female who, two years prior, suddenly lost hearing in her left ear after a 24-hour episode of nausea, vomiting, and left ear pain. She presented to our clinic two years after the episode, long after the window for evidence-based treatment for acute SSNHL, such as corticosteroid therapy or antivirals, had passed. However, she remembered the moment of her hearing loss vividly, an uncommon occurrence in pediatric patients. CT, MRI, family history, and physical exam were unremarkable. The patient had a brief hearing aid trial where she described being able to hear the sound but did not have any clarity in understanding the sound. The patient was ultimately treated with a unilateral cochlear implant and showed excellent subjective and audiogram responses. Continued research on the management of SSNHL in pediatric patients who present outside of the acute therapeutic window is needed.

3.
Cureus ; 15(2): e35358, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36974250

RESUMO

We discuss the unusual presentation and subsequent diagnosis of a patient with a glomus tympanicum tumor, also known as middle ear paraganglioma, which is a rare and benign tumor of the middle ear that usually presents with pulsatile tinnitus, cranial nerve pathology, hearing loss, and dizziness. The patient was a 35-year-old female with no past medical or surgical history who presented with a three-year history of mild left-ear hearing loss. The initial examination was negative for otalgia or otorrhea but was notable for a mass filling her left ear canal. The patient denied pulsatile tinnitus or dizziness. CT imaging was used to examine the soft tissue mass in the middle ear and ear canal and was consistent with a soft tissue heterogeneous mass with a subsequent biopsy confirming a diagnosis of paraganglioma. After the diagnosis, a laser surgical excision was scheduled to remove the tumor. Constant awareness is needed to examine the different presentations of middle ear paragangliomas so that appropriate treatment is promptly provided.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...