Phys Med Biol ; 65(22): 225037, 2020 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-32937602

RESUMO

This work aims to assess the efficacy of x-ray quality assurance tests undertaken on fluoroscopy units in the UK. Information was gathered on the results of image quality tests recommended by the reports of the Institute of Physics and Engineering in Medicine, and those additionally undertaken by medical physics departments. The assessment of efficacy considers the frequency with which a test result breaches the remedial level or other relevant threshold where applicable. The third quartile of those results exceeding the remedial level or threshold is used to estimate the severity of such a breach in terms of potential impact on patient dose and image quality. A risk assessment approach is then used to recommend to what degree, if any, the test should be included in an on-going test regimen. Data was analysed from 469 testing sessions to 337 unique fluoroscopy units throughout the UK. Across all tests, the rate with which the remedial level was exceeded varied from 0-10.6%, with severity ranging from little or none to major degradation to image quality or significant increase on population dose. Where possible, the data has also been used to produce representative ranges for the results of image quality tests. These could be useful as an up to date comparator for those sites considering the purchase of or commissioning new equipment. Overall the results indicate a wide range for the efficacy of those tests undertaken at present; this can be used to review local test protocols and to inform future changes to national guidance in the UK. The results also highlight some tests where measurement technique varies significantly throughout the UK, making any valid comparison difficult. This may indicate a need for further guidance on how best to undertake these tests.


Assuntos
Fluoroscopia/normas , Sociedades Médicas , Humanos , Controle de Qualidade , Relatório de Pesquisa , Medição de Risco
2.
JFMS Open Rep ; 6(1): 2055116920908963, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32206328

RESUMO

CASE SUMMARY: A castrated male domestic shorthair cat from a wooded area in Missouri had recovered from typical severe cytauxzoonosis at 4 years of age, after intensive in-hospital supportive care and administration of atovaquone and azithromycin. At 11 years of age, the same cat again experienced an acute febrile illness compatible with cytauxzoonosis. Intraerythrocytic piroplasms typical of Cytauxzoon felis were identified by cytology. The owners opted for euthanasia but allowed collection of splenic and hepatic tissue for histopathologic examination. Schizont-laden macrophages were identified in both tissue specimens, confirming active cytauxzoonosis at the time of the cat's death. RELEVANCE AND NOVEL INFORMATION: Although cats that have recovered from cytauxzoonosis can harbor red blood cell piroplasms for many years without apparent clinical illness, repeat illness owing to either disease recrudescence or repeat infection has never been documented. In fact, recovered cats have been thought to be resistant to reinfection and subsequent illness. This report describes a cat that had recovered from documented cytauxzoonosis 7 years previously and then developed a subsequent clinical illness typical of cytauxzoonosis, which was accompanied not only by intraerythrocytic piroplasms, but also by schizont-laden tissue macrophages pathognomonic of clinical cytauxzoonosis.

3.
Phys Med Biol ; 64(19): 195011, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31422951

RESUMO

This work aims to assess the efficacy of x-ray quality assurance tests undertaken on fluoroscopy units in the UK. Information was gathered on the results of dosimetry and safety tests recommended by the reports of the Institute of Physics and Engineering in Medicine, and those additionally undertaken by medical physics departments. The assessment of efficacy considers the frequency with which a test result breaches the remedial level or other relevant threshold where applicable. The third quartile of those results exceeding the remedial level or threshold is used to estimate the severity of such a breach in terms of potential impact on patient dose and image quality. A risk assessment approach is then used to recommend to what degree, if any, the test should be included in an on-going test regimen. Data was analysed from 468 testing sessions to 336 unique fluoroscopy units throughout the UK. Across all tests, the rate with which the remedial level was exceeded varied from 0%-29.5%, with severity ranging from little or none to major degradation to image quality or significant increase on population dose. Where possible, the data has also been used to produce representative ranges for the results of dosimetric tests. These could be useful as an up to date comparator for those sites considering the purchase of or commissioning new equipment. Overall the results indicate a wide range for the efficacy of those tests undertaken at present; this can be used to review local test protocols and to inform future changes to national guidance in the UK. The results also highlight some tests where measurement technique varies significantly throughout the UK, making any valid comparison difficult. This may indicate a need for further guidance on how best to undertake these tests.


Assuntos
Fluoroscopia , Radiometria , Segurança , Sociedades Médicas , Humanos , Controle de Qualidade , Medição de Risco
4.
Phys Med Biol ; 63(24): 245011, 2018 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-30523992

RESUMO

This work aims to assess the efficacy of current x-ray quality assurance (QA) testing regimes on tube and generator systems for general radiographic usage in the UK. 1393 sets of QA results data from nine UK medical physics departments were collected and analysed. Test failure rates ranged from 0% to 39% and were used to assess the likelihood of the test finding a fault. The magnitude of the recorded faults were used to assess the severity of the failure with due consideration to its impact on image quality and patient dose. The severity and likelihood of the faults were used along with a risk matrix to assess the efficacy of each test. Eleven tests were graded 'orange' (indicating an effective test that should be continued), four tests were graded 'yellow' (indicating a less effective test that may be continued with a lower frequency considered) and four tests were graded green (indicating a low efficacy test that could be removed from test regimes).


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/normas , Radiografia/instrumentação , Radiografia/normas , Radiometria/métodos , Medição de Risco/métodos , Humanos , Raios X
5.
Phys Chem Chem Phys ; 20(1): 694, 2017 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-29218348

RESUMO

Correction for 'A simple model of burst nucleation' by Alexandr Baronov et al., Phys. Chem. Chem. Phys., 2015, 17, 20846-20852.

7.
Phys Chem Chem Phys ; 17(32): 20846-52, 2015 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-26214058

RESUMO

We introduce a comprehensive quantitative treatment for burst nucleation (BN)-a kinetic pathway toward self-assembly or crystallization defined by an extended post-supersaturation induction period, followed by a burst of nucleation, and finally the growth of existing stable assemblages absent the formation of new ones-based on a hybrid mean field rate equation model incorporating thermodynamic treatment of the saturated solvent from classical nucleation theory. A key element is the inclusion of a concentration-dependent critical nucleus size, determined self-consistently along with the subcritical cluster population density. The model is applied to an example experimental study of crystallization in tetracene films prepared by organic vapor-liquid-solid deposition, where good agreement is observed with several aspects of the experiment using a single, physically well-defined adjustable parameter. The model predicts many important features of the experiment, and can be generalized to describe other self-organizing systems exhibiting BN kinetics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...