Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 66(1): 257-262, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993418

RESUMO

OBJECTIVE: In this paper, we investigate the impact of perfusion on the performance of microwave ablation across a large frequency range. METHODS: We designed multiple microwave ablation antennas to operate in liver tissue at discrete frequencies in the range 1.9-18 GHz. We performed electromagnetic simulations to calculate microwave power absorption patterns. Five-minute, 25 W ablation experiments were performed at each frequency in perfused and nonperfused ex vivo porcine livers, and thermal lesion dimensions were measured. RESULTS: The volume of greatest microwave power absorption shrinks by two orders of magnitude as the frequency is increased from 1.9 to 18 GHz. Mean thermal lesion volumes are consistent across the frequency range for a given perfusion state and are about three times smaller under active perfusion. Typical thermal lesion diameters (perpendicular to the antenna axis) were 24 mm and 16 mm for nonperfused and perfused ablations, respectively. No significant differences in axial ratio were observed among different frequency groups in active-perfusion experiments. CONCLUSION: Higher-frequency microwave ablation produces thermal lesions with volumes comparable to those achieved at lower frequencies, even in strongly perfused environments. SIGNIFICANCE: Higher-frequency microwave ablation is appealing because it allows for more flexibility in antenna design. A critical issue concerning the feasibility of higher frequency microwave ablation, considering its strong dependence on heat diffusion to grow thermal lesions, is its performance in strongly perfused environments. This paper shows that higher frequency microwave ablation achieves thermal lesions comparable to those from microwave ablation performed at conventional frequencies in both non- and strongly perfused environments.


Assuntos
Técnicas de Ablação/métodos , Fígado , Micro-Ondas , Perfusão/métodos , Animais , Simulação por Computador , Fígado/efeitos da radiação , Fígado/cirurgia , Suínos
2.
Int J Hyperthermia ; 33(1): 61-68, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27443394

RESUMO

PURPOSE: The use of higher frequencies in percutaneous microwave ablation (MWA) may offer compelling interstitial antenna design advantages over the 915 MHz and 2.45 GHz frequencies typically employed in current systems. To evaluate the impact of higher frequencies on ablation performance, we conducted a comprehensive computational and experimental study of microwave absorption and tissue heating as a function of frequency. METHODS: We performed electromagnetic and thermal simulations of MWA in ex vivo and in vivo porcine muscle at discrete frequencies in the 1.9-26 GHz range. Ex vivo ablation experiments were performed in the 1.9-18 GHz range. We tracked the size of the ablation zone across frequency for constant input power and ablation duration. Further, we conducted simulations to investigate antenna feed line heating as a function of frequency, input power, and cable diameter. RESULTS: As the frequency was increased from 1.9 to 26 GHz the resulting ablation zone dimensions decreased in the longitudinal direction while remaining relatively constant in the radial direction; thus at higher frequencies the overall ablation zone was more spherical. However, cable heating at higher frequencies became more problematic for smaller diameter cables at constant input power. CONCLUSION: Comparably sized ablation zones are achievable well above 1.9 GHz, despite increasingly localised power absorption. Specific absorption rate alone does not accurately predict ablation performance, particularly at higher frequencies where thermal diffusion plays an important role. Cable heating due to ohmic losses at higher frequencies may be controlled through judicious choices of input power and cable diameter.


Assuntos
Técnicas de Ablação/métodos , Micro-Ondas , Músculos/cirurgia , Técnicas de Ablação/instrumentação , Animais , Simulação por Computador , Desenho de Equipamento , Suínos
3.
IEEE Trans Antennas Propag ; 62(10): 5126-5132, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26663930

RESUMO

We present a focal-beamforming-enhanced formulation of the distorted Born iterative method (DBIM) for microwave breast imaging. Incorporating beamforming into the imaging algorithm has the potential to mitigate the effect of noise on the image reconstruction. We apply the focal-beamforming-enhanced DBIM algorithm to simulated array measurements from two MRI-derived, anatomically realistic numerical breast phantoms and compare its performance to that of the DBIM formulated with two non-focal schemes. The first scheme simply averages scattered field data from reciprocal antenna pairs while the second scheme discards reciprocal pairs. Images of the dielectric properties are reconstructed for signal-to-noise ratios (SNR) ranging from 35 dB down to 0 dB. We show that, for low SNR, the focal beamforming algorithm creates reconstructions that are of higher fidelity with respect to the exact dielectric profiles of the phantoms as compared to reconstructions created using the non-focal schemes. At high SNR, the focal and non-focal reconstructions are of comparable quality.

4.
IEEE Trans Biomed Eng ; 59(3): 627-33, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21622068

RESUMO

We propose the use of a polycaprolactone (PCL)-based thermoplastic mesh as a tissue-immobilization interface for microwave imaging and microwave hyperthermia treatment. An investigation of the dielectric properties of two PCL-based thermoplastic materials in the frequency range of 0.5-3.5 GHz is presented. The frequency-dependent dielectric constant and effective conductivity of the PCL-based thermoplastics are characterized using measurements of microstrip transmission lines fabricated on substrates comprised of the thermoplastic meshes. We also examine the impact of the presence of a PCL-based thermoplastic mesh on microwave breast imaging. We use a numerical test bed comprised of a previously reported 3-D anatomically realistic breast phantom and a multi-frequency microwave inverse scattering algorithm. We demonstrate that the PCL-based thermoplastic material and the assumed biocompatible medium of vegetable oil are sufficiently well matched such that the PCL layer may be neglected by the imaging solution without sacrificing imaging quality. Our results suggest that PCL-based thermoplastics are promising materials as tissue immobilization structures for microwave diagnostic and therapeutic applications.


Assuntos
Diagnóstico por Imagem/instrumentação , Hipertermia Induzida/métodos , Imobilização/instrumentação , Micro-Ondas/uso terapêutico , Poliésteres/química , Algoritmos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/radioterapia , Condutividade Elétrica , Desenho de Equipamento , Feminino , Humanos , Teste de Materiais , Imagens de Fantasmas , Óleos de Plantas , Espalhamento de Radiação
5.
IEEE Trans Biomed Eng ; 59(4): 936-45, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22113770

RESUMO

A variety of methods have been applied to the inverse scattering problem for breast imaging at microwave frequencies. While many techniques have been leveraged toward a microwave imaging solution, they are all fundamentally dependent on the quality of the scattering data. Evaluating and optimizing the information contained in the data are, therefore, instrumental in understanding and achieving optimal performance from any particular imaging method. In this paper, a method of analysis is employed for the evaluation of the information contained in simulated scattering data from a known dielectric profile. The method estimates optimal imaging performance by mapping the data through the inverse of the scattering system. The inverse is computed by truncated singular-value decomposition of a system of scattering equations. The equations are made linear by use of the exact total fields in the imaging volume, which are available in the computational domain. The analysis is applied to anatomically realistic numerical breast phantoms. The utility of the method is demonstrated for a given imaging system through the analysis of various considerations in system design and problem formulation. The method offers an avenue for decoupling the problem of data selection from the problem of image formation from that data.


Assuntos
Mama/anatomia & histologia , Mama/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Micro-Ondas , Modelos Biológicos , Radar , Simulação por Computador , Feminino , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
6.
IEEE Antennas Wirel Propag Lett ; 11: 1610-1613, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-25132808

RESUMO

We propose a 3-D-printed breast phantom for use in preclinical experimental microwave imaging studies. The phantom is derived from an MRI of a human subject; thus, it is anthropomorphic, and its interior is very similar to an actual distribution of fibroglandular tissues. Adipose tissue in the breast is represented by the solid plastic (printed) regions of the phantom, while fibroglandular tissue is represented by liquid-filled voids in the plastic. The liquid is chosen to provide a biologically relevant dielectric contrast with the printed plastic. Such a phantom enables validation of microwave imaging techniques. We describe the procedure for generating the 3-D-printed breast phantom and present the measured dielectric properties of the 3-D-printed plastic over the frequency range 0.5-3.5 GHz. We also provide an example of a suitable liquid for filling the fibroglandular voids in the plastic.

7.
Med Phys ; 37(8): 4210-26, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20879582

RESUMO

PURPOSE: Breast density measurement has the potential to play an important role in individualized breast cancer risk assessment and prevention decisions. Routine evaluation of breast density will require the availability of a low-cost, nonionizing, three-dimensional (3-D) tomographic imaging modality that exploits a strong properties contrast between dense fibroglandular tissue and less dense adipose tissue. The purpose of this computational study is to investigate the performance of 3-D tomography using low-power microwaves to reconstruct the spatial distribution of breast tissue dielectric properties and to evaluate the modality for application to breast density characterization. METHODS: State-of-the-art 3-D numerical breast phantoms that are realistic in both structural and dielectric properties are employed. The test phantoms include one sample from each of four classes of mammographic breast density. Since the properties of these phantoms are known exactly, these testbeds serve as a rigorous benchmark for the imaging results. The distorted Born iterative imaging method is applied to simulated array measurements of the numerical phantoms. The forward solver in the imaging algorithm employs the finite-difference time-domain method of solving the time-domain Maxwell's equations, and the dielectric profiles are estimated using an integral equation form of the Helmholtz wave equation. A multiple-frequency, bound-constrained, vector field inverse scattering solution is implemented that enables practical inversion of the large-scale 3-D problem. Knowledge of the frequency-dependent characteristic of breast tissues at microwave frequencies is exploited to obtain a parametric reconstruction of the dispersive dielectric profile of the interior of the breast. Imaging is performed on a high-resolution voxel basis and the solution is bounded by a known range of dielectric properties of the constituent breast tissues. The imaging method is validated using a breast phantom with a single, high-contrast interior scattering target in an otherwise homogeneous interior. The method is then used to image a set of realistic numerical breast phantoms of varied fibroglandular tissue density. RESULTS: Imaging results are presented for each numerical phantom and show robustness of the method relative to tissue density. In each case, the distribution of fibroglandular tissues is well represented in the resulting images. The resolution of the images at the frequencies employed is wider than the feature dimensions of the normal tissue structures, resulting in a smearing of their reconstruction. CONCLUSIONS: The results of this study support the utility of 3-D microwave tomography for imaging the distribution of normal tissues in the breast, specifically, dense fibroglandular tissue versus less dense adipose tissue, and suggest that further investigation of its use for volumetric evaluation of breast density is warranted.


Assuntos
Algoritmos , Neoplasias da Mama/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Micro-Ondas , Aumento da Imagem/métodos , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
8.
IEEE Trans Med Imaging ; 28(7): 969-81, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19211350

RESUMO

Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete mesh is replaced with a relatively small number of smooth basis functions. The dimension of the tomography problem is reduced by estimating the coefficients of the basis functions instead of the dielectric properties at each element in the discrete mesh. The basis functions are constructed using knowledge of the location of the breast surface. The number of functions used in the basis can be varied to balance resolution and computational complexity. The reduced dimension of the inverse problem enables application of a computationally efficient, multiple-frequency inverse scattering algorithm in 3-D. The efficacy of the proposed approach is verified using two 3-D anatomically realistic numerical breast phantoms. It is shown for the case of single-frequency microwave tomography that the imaging accuracy is comparable to that obtained when the original discrete mesh is used, despite the reduction of the dimension of the inverse problem. Results are also shown for a multiple-frequency algorithm where it is computationally challenging to use the original discrete mesh.


Assuntos
Mama/anatomia & histologia , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Micro-Ondas , Tomografia/métodos , Algoritmos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Feminino , Humanos , Imagens de Fantasmas
9.
IEEE Trans Biomed Eng ; 55(1): 247-56, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18232368

RESUMO

This paper presents an algorithm for estimating the location of the breast surface from scattered ultrawideband (UWB) microwave signals recorded across an antenna array. Knowing the location of the breast surface can improve imaging performance if incorporated as a priori information into recently proposed microwave imaging algorithms. These techniques transmit low-power microwaves into the breast using an antenna array, which in turn measures the scattered microwave signals for the purpose of detecting anomalies or changes in the dielectric properties of breast tissue. Our proposed surface identification algorithm consists of three procedures, the first of which estimates M points on the breast surface given M channels of measured microwave backscatter data. The second procedure applies interpolation and extrapolation to these M points to generate N > M points that are approximately uniformly distributed over the breast surface, while the third procedure uses these N points to generate a 3-D estimated breast surface. Numerical as well as experimental tests indicate that the maximum absolute error in the estimated surface generated by the algorithm is on the order of several millimeters. An error analysis conducted for a basic microwave radar imaging algorithm (least-squares narrowband beamforming) indicates that this level of error is acceptable. A key advantage of the algorithm is that it uses the same measured signals that are used for UWB microwave imaging, thereby minimizing patient scan time and avoiding the need for additional hardware.


Assuntos
Mama/anatomia & histologia , Mama/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Micro-Ondas , Modelos Biológicos , Radiometria/métodos , Simulação por Computador , Humanos , Doses de Radiação , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...