Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 66(790): 907-14, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8220975

RESUMO

A second treatment room and beam line has been constructed at the Cyclotron Unit at Clatterbridge for the purpose of using 62 MeV protons for the treatment of ocular melanoma. A uniform beam is produced by a double foil scattering system. The initial Bragg peak is spread across the target volume by the use of beam modulators. These are rotating four-vaned stepped absorbers made from Perspex. Two beam lines can be configured with different positions of modulators and range limiters. The first has a maximum penetration of 31.9 +/- 0.2 mm in water and the second a penetration of 31.2 +/- 0.2 mm. The second configuration has the advantage of less variation in beam penumbra, with a typical value of 1.7 +/- 0.1 mm for the 90% to 10% decrement lines. The patients are treated with individually shaped collimators. Beam output varies by less than 2% over the range of collimator areas used. The resulting whole-body dose equivalent to patient has also been assessed. In the first three years of operation over 250 patients have been treated.


Assuntos
Neoplasias Oculares/radioterapia , Melanoma/radioterapia , Radioterapia de Alta Energia , Humanos , Prótons , Doses de Radiação , Dosagem Radioterapêutica , Espalhamento de Radiação
2.
Br J Obstet Gynaecol ; 89(12): 1021-30, 1982 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7171512

RESUMO

A new method of real-time computer surveillance during labour is described with a commercially available "low-cost' microcomputer and integral video display unit (VDU). The fetal monitoring program gives accurate and reliable information on eight parameters of fetal and maternal wellbeing, four of which may be displayed simultaneously, with the facility of instant data recall. Emphasis is on simplicity of operation, and clarity of data display in the form of horizontal bar graphs updated at 5-min intervals, with most recent information in numerical form. Flexibility of the system enables program modification with relative ease, and adaptation to two unmodified commercial electronic fetal monitors.


Assuntos
Computadores , Monitorização Fetal/métodos , Trabalho de Parto , Microcomputadores , Colo do Útero/fisiologia , Feminino , Coração Fetal/fisiologia , Monitorização Fetal/instrumentação , Frequência Cardíaca , Humanos , Gravidez , Contração Uterina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...