Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Expert Rev Med Devices ; 19(8): 649-656, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36200143

RESUMO

BACKGROUND: This multicenter prospective, randomized controlled clinical trial compared the clinical performance of supraglottic airway device (SAD) BlockBusterTM and laryngeal mask airway (LMA) Supreme for airway maintenance in anesthetized, paralyzed adult patients. METHODS: A total of 651 adult patients scheduled for elective surgery in 13 hospitals were randomly allocated into BlockBuster group (n = 351) or Supreme group (n = 300). The primary outcome was oropharyngeal leak pressure (OLP). Duration and ease of insertion, fiberscopic view of positioning, airway manipulations, and complications were also assessed. RESULTS: The OLP was significantly higher in BlockBuster group compared with Supreme group (29.9 ± 4.2 cmH2O vs 27.4 ± 4.3 cmH2O, p < 0.001). Success rate of insertion at the first attempt (90.2% vs 85.1%, p = 0.027), rate of optimal fiberscopic view (p = 0.002) and satisfactory positioning of SAD (p < 0.001) were significantly increased in BlockBuster group. CONCLUSIONS: Both SAD BlockBusterTM and LMA Supreme are safe, effective, and easy-to-use devices for airway maintenance in anesthetized, paralyzed adult patients, but the SAD BlockBusterTM is superior to LMA Supreme in terms of OLP, success rate at the first attempt, and fiber-optic view of positioning. TRIAL REGISTRATION: The trial is registered at www.chictr.org.cn (ChiCTR-ONC-16009105).


Assuntos
Máscaras Laríngeas , Adulto , Humanos , Estudos Prospectivos , Tecnologia de Fibra Óptica , Orofaringe
2.
World J Emerg Med ; 5(4): 286-90, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25548603

RESUMO

BACKGROUND: This study aimed to investigate the epidemiological and clinical characteristics of patients with heat-related illness, and guide the prevention, diagnosis and treatment of heat-related illness. METHODS: From June 2013 to August 2013, seventy patients with heat-related illness were treated at Jinshan Hospital of Fudan University, and their epidemiological characteristics, laboratory results, treatment and prognosis were retrospectively analyzed. RESULTS: In the 70 patients, 18 patients suffered from heat stroke and 52 patients from non-heat stroke. When the environmnent temperature was above 35 °C, the body temperature of the patients began to increase markedly. The patients with heat stroke were significantly older than those with non-heat stroke (P<0.05). The body temperature, heart rate, blood glucose, blood lactate dehydrogenase and blood creatine kinase in the patients with heat stroke were higher than those in the patients with non-heat stroke (P<0.05). Blood lactate dehydrogenase and blood creatine kinase were positively correlated with body temperature (r=0.801). CONCLUSION: When the environmental temperature goes above 35 °C, heat-related illness should be prevented, especially in the elderly. The body temperature, heart rate, blood glucose, blood lactate dehydrogenase and blood creatine kinase in patients with heat stroke are higher than those in patients with non-heat stroke. Blood lactate dehydrogenase and blood creatine kinase are positively correlated with body temperature, but their relationship with heat-related illness awaits further study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...