Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 23(5): 1810-1819, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36648158

RESUMO

The low piezoelectricity of piezoelectric polymers significantly restricts their applications. Introducing inorganic fillers can slightly improve the piezoelectricity of polymers, whereas it is usually at the cost of flexibility and durability. In this work, using a modulus-modulated core-shell structure strategy, all-organic nanofibers with remarkable piezoelectricity were designed and prepared by a coaxial electrospinning method. It was surprisingly found that the introduction of a nonpiezoelectric polymeric core (e.g., polycarbonate, PC) can result in 110% piezoelectric coefficient (d33) enhancement in a poly(vinylidenefluoride-co-trifluoroethylene) (PVDF-TrFE) nanofiber. Accordingly, the all-organic PVDF-TrFE@PC core-shell nanofiber exhibits record-high energy-harvesting performance (i.e., 126 V output voltage, 710 mW m-2 power density) among the reported organic piezoelectric materials. In addition, the excellent sensing capability of the core-shell nanofiber enabled us to develop a wireless vibration monitoring and analyzing system, which realizes the real-time vibration detection of a power transformer.

2.
Sensors (Basel) ; 17(8)2017 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-28820444

RESUMO

Effective Partial Discharge (PD) localization can detect the insulation problems of the power equipment in a substation and improve the reliability of power systems. Typical Ultra-High Frequency (UHF) PD localization methods are mainly based on time difference information, which need a high sampling rate system. This paper proposes a novel PD localization method based on a received signal strength indicator (RSSI) fingerprint to quickly locate the power equipment with potential insulation defects. The proposed method consists of two stages. In the offline stage, the RSSI fingerprint data of the detection area is measured by a wireless UHF sensor array and processed by a clustering algorithm to reduce the PD interference and abnormal RSSI values. In the online stage, when PD happens, the RSSI fingerprint of PD is measured via the input of pattern recognition for PD localization. To achieve an accurate localization, the pattern recognition process is divided into two steps: a preliminary localization is implemented by cluster recognition to reduce the localization region, and the compressed sensing algorithm is used for accurate PD localization. A field test in a substation indicates that the mean localization error of the proposed method is 1.25 m, and 89.6% localization errors are less than 3 m.

3.
Rev Sci Instrum ; 87(7): 075119, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27475607

RESUMO

This paper presents a novel energy-harvesting model which takes the primary current, secondary turns, dimension, the magnitude of magnetic flux density B, and the core loss resistance into consideration systematically. The relationship among the potential maximum output power, the dimension of energy harvesting coil (EHC), the load type of EHC, and the secondary turns is predicted by theoretical analysis and further verified by experiments. A high power density harvester is also developed and tested. It is shown that the power density of this novel harvester is 0.7 mW/g at 10 A, which is more than 2 times powerful than the traditional ones. Hence, it could lighten the half weight of the harvester at the same conditions.

4.
Sensors (Basel) ; 16(5)2016 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-27213402

RESUMO

The accurate detection of high-frequency transient fault currents in overhead transmission lines is the basis of malfunction detection and diagnosis. This paper proposes a novel differential winding printed circuit board (PCB) Rogowski coil for the detection of transient fault currents in overhead transmission lines. The interference mechanism of the sensor surrounding the overhead transmission line is analyzed and the guideline for the interference elimination is obtained, and then a differential winding printed circuit board (PCB) Rogowski coil is proposed, where the branch and return line of the PCB coil were designed to be strictly symmetrical by using a joining structure of two semi-rings and collinear twisted pair differential windings in each semi-ring. A serial test is conducted, including the frequency response, linearity, and anti-interference performance as well as a comparison with commercial sensors. Results show that a PCB Rogowski coil has good linearity and resistance to various external magnetic field interferences, thus enabling it to be widely applied in fault-current-collecting devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...