Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-284293

RESUMO

<p><b>OBJECTIVE</b>To investigate the feasibility of hip arthroplasty in the treatment of elderly patients with Evans I-III intertrochanteric fracture of femur by analyzing its biomechanics characters.</p><p><b>METHODS</b>We solved the CT digital image files with the graphics processing software Mimics at DICOM 3.0 standard, and reconstructed the three-dimensional entity of femur with CAD modeling software Unigraphics. Then the fracture line was defined in the model as the line between the tip of greater trochanter and inferior margin of small trochanter, above which the upper bone was removed. Afterwards the two prosthesises with different stem lengths (120 mm and 170 mm) were implanted into the fracture model respectively as hip arthroplasty with 3 mm bone cement layer between prosthesis and femur, and the bone defect was repatched with 5 mm bone cement layer. A three-dimensional finite element model was established with finite element analysis software ABAQUS 6.5. We formulated different material parameters under the stress condition standing with single leg to build the stress distribution map of the femur prosthesis, and took 5 loci of region of stress concentration to calculate the mean value of stress.</p><p><b>RESULTS</b>The stress distribution maps of the short and long stem length prothesises were similar. And there were two areas of stress concentration, including the upper portion and the lower portion close to the joint of the prosthesis stem, and the stress concentration in the junction part was obviously between the lower portion and the upper area of the small trachanter. The stress reached the first concentration area at the junction and then gradually reached the second concentration area at the interior terminal of the stem. While the stress gradually increased along the lateral prosthesis stem, and reached the stress concentration area at the end.</p><p><b>CONCLUSIONS</b>The stress distribution maps in the femur prosthesises are similar between hip arthroplasty in the treatment of intertrochanteric fracture of femur and the traditional hip arthroplasty surgery. The peak stress values are higher in the long stem prosthesis in the treatment of intertrochanteric fracture of femur than the short type, while they are under the rupture value of the metal.</p>


Assuntos
Idoso , Feminino , Humanos , Artroplastia de Quadril , Métodos , Fenômenos Biomecânicos , Cimentos Ósseos , Simulação por Computador , Análise de Elementos Finitos , Fraturas do Quadril , Cirurgia Geral , Prótese de Quadril , Processamento de Imagem Assistida por Computador , Software , Estresse Mecânico
2.
Chinese Medical Journal ; (24): 4061-4065, 2012.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-339900

RESUMO

<p><b>BACKGROUND</b>Features of necrotic lesions and various interventions could affect the biomechanics of the femoral head. A three-dimensional finite-element analysis was designed to demonstrate necrotic femoral head stress changes with various sizes of necrotic lesions, and evaluate the effect of tantalum rods on preventing femoral head cracking.</p><p><b>METHODS</b>Femoral computed tomography scans were used to build a normal three-dimensional finite-element femoral head model in a computer. Based on the normal model, necrotic models of different lesion diameters (15 mm, 20 mm and 30 mm) were created, as were the repaired models with tantalum rods for each diameter. After a series of meshing and force loading, the von Mises stress distributions, simulating single-legged stance, and stresses on specific points under loaded conditions were determined for each model.</p><p><b>RESULTS</b>Deep exploration into the burdened area of the femoral head indicated that higher stresses to the femoral head were observed with a larger necrotic lesion; the largest stress concentration, 91.3 MPa, was found on the femoral head with a lesion diameter of 30 mm. By contrast, topical stress on the surface of the necrotic regions was lowered following implantation of a tantalum rod, and the changes in stress were significant in models with lesions of 15 mm and 30 mm in diameter, with the best biomechanical benefit from the tantalum rod found with a lesion diameter of 15 mm.</p><p><b>CONCLUSIONS</b>Femoral heads with larger necrotic lesions usually have a higher stress concentration and a higher risk of collapse. Various sized lesions on the femoral head can benefit from the mechanical support offered by the implantation of a tantalum rod; however, femoral heads with smaller sized lesions may benefit more. A thorough evaluation of the lesion size should be conducted prior to the use of tantalum rod implants in the treatment of femoral head necrosis.</p>


Assuntos
Humanos , Cabeça do Fêmur , Fisiologia , Necrose da Cabeça do Fêmur , Análise de Elementos Finitos , Estresse Mecânico
3.
Chinese Medical Journal ; (24): 2543-2547, 2012.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-283725

RESUMO

<p><b>BACKGROUND</b>While intra-articular injection of sinomenine hydrochloride has a therapeutic effect on osteoarthritis, it has a short half-life, and is thermolabile and photolabile. The aim of this research was to evaluate the sustained-release of sinomenine hydrochloride from an injectable sinomenine hydrochloride and sodium hyaluronate compound (CSSSI) and its therapeutic effect in a rabbit model of osteoarthritis following intra-articular injection.</p><p><b>METHODS</b>An injectable compound consisting of 1% sodium hyaluronate and 2.5% sinomenine hydrochloride was prepared and kept as the experiment group, and 2.5% sinomenine hydrochloride was prepared and kept as the control group. The cumulative mass release was measured at different time points in each group in vitro. Sixty-five male Zelanian rabbits were randomly divided into five groups: 15 (30 knees) each for the control, sodium hyaluronate, sinomenine hydrochloride, and CSSSI groups respectively, and five (10 knees) for the modeling group. Papain was injected into both knees of each rabbit for model establishment. Subsequently, 0.2 ml of the corresponding drugs was injected into the articular cavities of the remaining experiment groups, while the control group was treated with 0.2 ml normal saline. All groups were treated once a week for 4 weeks. Seven days after the last treatment, knees were anatomized to perform pathological observations and Mankin's evaluation of the synovium. Four groups were compared using the SPSS 13.0 software package.</p><p><b>RESULTS</b>In the in vitro sustained-release experiments, 90% of the drug was released in the experiment group 360 minutes following the injection. Comparison of the Mankin's evaluations of the four groups illustrated statistical discrepancies (P < 0.05). In further paired comparisons of the CSSSI group vs. modeling control/sodium hyaluronate/sinomenine hydrochloride groups, statistical significance was uniformly obtained. Moreover, sodium hyaluronate and sinomenine hydrochloride treatments showed significant improvement over the modeling control (P < 0.05), whereas sodium hyaluronate vs. sinomenine hydrochloride comparison failed to reach significance (P > 0.05).</p><p><b>CONCLUSIONS</b>CSSSI has a sustained-release effect on sinomenine hydrochloride. Intra-articular injection of CSSSI was significantly better than the sole sodium hyaluronate or sinomenine hydrochloride for the treatment of osteoarthritis in a rabbit model.</p>


Assuntos
Animais , Masculino , Coelhos , Ácido Hialurônico , Usos Terapêuticos , Injeções Intra-Articulares , Morfinanos , Usos Terapêuticos , Osteoartrite , Tratamento Farmacológico , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...