Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 20261, 2020 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-33219260

RESUMO

Endoluminal surgery for the treatment of colorectal neoplasia is typically carried out using electrocautery tools which imply limited precision and the risk of harm through collateral thermal damage to the adjacent healthy tissue. As a potential alternative, we present the successful colonic epithelial laser ablation by means of picosecond laser pulses. Laser ablation studies performed in ex-vivo colon tissue result in cavities with comparable thickness to early stage colorectal cancers. The corresponding histology sections exhibit only minimal collateral damage to the surrounding tissue and the depth of the ablation can be controlled precisely by means of the pulse energy. High-speed imaging has been used for the first time to visualize picosecond laser ablation of cancerous tissue in a clinically relevant model. This information was correlated with histopathology and optical surface profilometry revealing the dynamic nature of the laser tissue interaction and the need for temporal or spatial separation of pulses for optimum efficacy with regards to tissue removal. Overall, the application of picosecond laser pulses to ablate endoluminal bowel lesions demonstrates significantly improved precision and reduced thermal damage to the adjacent tissue in comparison to conventional procedures and hence will enable more precise surgical treatment of cancers.


Assuntos
Neoplasias Colorretais/cirurgia , Terapia a Laser , Animais , Modelos Animais de Doenças , Camundongos , Suínos
2.
Soft Matter ; 12(20): 4530-6, 2016 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-27094902

RESUMO

Dynamic control of the distribution of polystyrene suspended nanoparticles in evaporating droplets is investigated using a 2.9 µm high power laser. Under laser radiation a droplet is locally heated and fluid flows are induced that overcome the capillary flow, and thus a reversal of the coffee-stain effect is observed. Suspension particles are accumulated in a localised area, one order of magnitude smaller than the original droplet size. By scanning the laser beam over the droplet, particles can be deposited in an arbitrary pattern. This finding raises the possibility for direct laser writing of suspended particles through a liquid layer. Furthermore, a highly uniform coating is possible by manipulating the laser beam diameter and exposure time. The effect is expected to be universally applicable to aqueous solutions independent of solutes (either particles or molecules) and deposited substrates.

3.
Biomed Opt Express ; 4(2): 193-205, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23413120

RESUMO

We present the delivery of high energy microsecond pulses through a hollow-core negative-curvature fiber at 2.94 µm. The energy densities delivered far exceed those required for biological tissue manipulation and are of the order of 2300 J/cm(2). Tissue ablation was demonstrated on hard and soft tissue in dry and aqueous conditions with no detrimental effects to the fiber or catastrophic damage to the end facets. The energy is guided in a well confined single mode allowing for a small and controllable focused spot delivered flexibly to the point of operation. Hence, a mechanically and chemically robust alternative to the existing Er:YAG delivery systems is proposed which paves the way for new routes for minimally invasive surgical laser procedures.

4.
Opt Express ; 20(6): 6677-84, 2012 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-22418551

RESUMO

In this paper the delivery of high power Er:YAG laser pulses through a silica hollow core photonic crystal fibre is demonstrated. The Er:YAG wavelength of 2.94 µm is well beyond the normal transmittance of bulk silica but the unique hollow core guidance allows silica to guide in this regime. We have demonstrated for the first time the ability to deliver high energy pulses through an all-silica fibre at 2.94 µm. These silica fibres are mechanically and chemically robust, biocompatible and have low sensitivity to bending. A maximum pulse energy of 14 mJ at 2.94 µm was delivered through the fibre. This, to our knowledge, is the first time a silica hollow core photonic crystal fibre has been shown to transmit 2.94 µm laser light at a fluence exceeding the thresholds required for modification (e.g. cutting and drilling) of hard biological tissue. Consequently, laser delivery systems based on these fibres have the potential for the realization of novel, minimally-invasive surgical procedures.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers de Estado Sólido , Dióxido de Silício/química , Cristalização , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons , Porosidade
5.
Appl Opt ; 45(36): 9160-7, 2006 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-17151755

RESUMO

Hollow-core waveguides consisting of a glass capillary tube with an internal reflective coating are capable of delivering pulse energies of tens of millijoules with improved focusability compared to step index fibers of similar core diameter. We demonstrate the capability of these fibers to deliver high-power Q-switched pulses at the fundamental (1064 nm), second (532 nm), and third (355 nm) harmonics of a Nd:YAG laser, both in terms of peak power and beam quality delivered. In terms of peak power delivery, the primary limitation is the occurrence of bend-induced optical damage to the reflective coating. The damage mechanism and the influential factors are analyzed, in particular, the dependence upon the number of guided modes, core diameter, coating thicknesses, and input polarization alignment.