Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 45(7): 899-905, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38871372

RESUMO

BACKGROUND AND PURPOSE: The Neuroform Atlas stent and the LVIS Jr stent are intracranial microstent systems for the treatment of wide-neck intracranial aneurysms. Hence, this study aimed to compare the efficacy and safety of the Neuroform Atlas stent and the LVIS Jr stent for the treatment of unruptured intracranial aneurysms in parent arteries of <2 mm in diameter. MATERIALS AND METHODS: From March 2022 to April 2023, the clinical and imaging data of 135 patients with unruptured intracranial aneurysms treated with stent-assisted coiling using the Neuroform Atlas or LVIS Jr stent in parent arteries of <2 mm in diameter were retrospectively analyzed. Stent apposition was evaluated by high-resolution conebeam CT (HR-CBCT). Immediate aneurysm-embolization attenuation and occlusion at 6-month follow-up were evaluated using 2D DSA and the modified Raymond-Roy classification. Adverse events were recorded. Multivariate logistic regression analysis was undertaken to determine the independent factors affecting incomplete stent apposition. RESULTS: One hundred thirty-five patients (135 aneurysms) underwent stent-assisted coiling (66 Neuroform Atlas stents and 69 LVIS Jr stents). Intraoperative HR-CBCT showed that 1 Neuroform Atlas stent and 11 LVIS Jr stents had incomplete stent apposition at the aneurysm neck (P < .05). Perioperative complications occurred in 3 cases (2.22%). These comprised 2 cases of neurologic complications (1 case of distal intracranial vascular embolism and 1 case of cerebral parenchymal hemorrhage) and 1 case of severe postprocedural gastrointestinal hemorrhage. DSA follow-up showed 3 cases of aneurysm recurrence in the LVIS Jr group. Multivariate regression analysis showed that a stent angle of ≥75° (OR, 23.963; P = .005) or a parent artery diameter mismatch ratio of ≥1.25 (OR, 8.043; P = .037) were risk factors for incomplete stent apposition, especially for the LVIS Jr stent (OR, 20.297; P = .015). CONCLUSIONS: The Neuroform Atlas stent and LVIS Jr stent are efficacious in the treatment of unruptured intracranial aneurysms in parent arteries of <2 mm in diameter. Apposition of the LVIS Jr stent was worse than in the Neuroform Atlas stent at the neck of some aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Stents , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Adulto , Resultado do Tratamento , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Angiografia Cerebral , Tomografia Computadorizada de Feixe Cônico , Angiografia Digital
2.
Interv Neuroradiol ; : 15910199241254864, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38751187

RESUMO

PURPOSE: This study aims to compare the efficacy and safety of using overlapping low-profile visualized intraluminal support (LVIS) devices and flow diversion (FD) for the treatment of unruptured vertebral artery dissection (VAD) in the V3-V4 segments. METHODS: The clinical and imaging data of 71 patients with unruptured VAD in the V3-V4 segments who underwent either dual LVIS stenting (d-LVIS group) or single FD stenting (FD group) at our center from September 2014 to December 2021 were retrospectively analyzed. RESULTS: Immediate postoperative angiography revealed no significant difference in the degree of occlusion between the two groups in treating vertebral artery dissecting aneurysms (with or without noncompact coiling). However, the d-LVIS group had significantly higher fluoroscopy exposure time and total radiation exposure dose compared to the FD group. During the perioperative period, two cases of pontine infarction and one case of acute thrombosis were encountered. One patient died from subarachnoid hemorrhage during the follow-up period. For dissecting the aneurysm, angiographic follow-up (8.56 ± 1.96 months) showed similar healing outcomes between the two groups (with or without noncompact coiling). However, seven patients (7/40, 17.5%) showed poor healing and one patient showed mild in-stent stenosis. For simple dissection, angiographic follow-up (8.78 ± 1.83 months) showed patent lumens in both groups, with all dissections healing well, and two patients having mild in-stent stenosis. CONCLUSION: Both methods could effectively treat unruptured VAD in V3-V4 segments. Nevertheless, simple FD implantation is relatively easier to perform and involves lower radiation exposure.

3.
Clin Neuroradiol ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38451269

RESUMO

OBJECTIVE: To investigate the safety and efficacy of LVIS Jr stent-assisted coiling (SAC) of intracranial aneurysms (IAs) in small-diameter parent arteries and determine the factors influencing incomplete aneurysm occlusion. MATERIAL AND METHODS: Clinical and imaging data of 130 patients with IAs in small-diameter parent arteries that were treated with LVIS Jr SAC were retrospectively analyzed. Stent apposition was evaluated by high-resolution flat detector CT, and aneurysm embolization density was evaluated using 2D-DSA. Perioperative complications were recorded. Multivariate logistic regression analyses were performed to determine possible factors for incomplete aneurysm occlusion. RESULTS: In this study, 130 patients (60 and 70 patients with ruptured and unruptured aneurysms, respectively) were successfully treated with LVIS Jr SAC. Immediate digital subtraction angiography (DSA) showed that the aneurysm occlusion was Raymond-Roy class I, II, IIIa, and IIIb in 93 (71.5%), 24 (18.5%), 8 (6.2%), and 5 (3.8%) cases, respectively. There were three cases of acute in-stent thrombosis and two cases of severe vasospasm observed during the perioperative period. The 6­month follow-up angiograms indicated that complete aneurysm occlusion in 122 patients was 79.5% (97/122). Multivariate logistic regression analyses showed that an aneurysm size > 10.0 mm, parent artery mean diameter < 2.0 mm, and incomplete stent apposition at the aneurysm neck were possible risk factors for incomplete aneurysm occlusion. CONCLUSION: The LVIS Jr SAC is effective for managing IAs in small-diameter parent arteries. An aneurysm size > 10.0 mm, parent artery mean diameter < 2.0 mm, and incomplete stent apposition at the aneurysm neck are possible risk factors for incomplete aneurysm occlusion.

4.
AJNR Am J Neuroradiol ; 45(1): 16-21, 2023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38164561

RESUMO

BACKGROUND AND PURPOSE: Flow diversion treatment repairs aneurysms by altering the hemodynamics of the aneurysmal sac and providing a scaffold for endothelial cell adhesion. The purpose of this study was to investigate the correlation of flow diverter (FD) malapposition at the aneurysm neck with incomplete occlusion of small intracranial aneurysms (IAs) and investigate other factors that are possibly related to incomplete occlusion. MATERIALS AND METHODS: From January 2019 to June 2022, the clinical and imaging data for 153 patients (175 aneurysms) with unruptured small IAs treated with flow diversion were retrospectively analyzed. FD apposition at the aneurysm neck was evaluated by high-resolution conebeam CT (HR-CBCT), and the complete occlusion rate for aneurysms was judged according to the latest follow-up conventional angiography findings (≥6 months). Multivariate logistic regression analysis was used to determine factors associated with incomplete aneurysm occlusion. RESULTS: In total, 159 FDs were implanted in 153 patients. HR-CBCT performed after the deployment revealed FD malapposition at the aneurysm neck in 18 cases. According to the latest follow-up angiograms (average: 9.47 ± 3.35 months), the complete aneurysm occlusion rate was 66.9%. The complete occlusion rates for incomplete and complete stent apposition at the neck were 38.9% (7/18) and 70.1% (110/157), respectively. The results of regression analysis showed that an aneurysm sac with branch vessels (OR, 2.937; P = .018), incomplete stent apposition at the aneurysm neck (OR, 3.561; P = .023), and a large aneurysm diameter (OR, 1.533; P = .028) were positive predictors of incomplete aneurysm occlusion. CONCLUSIONS: An aneurysm sac with branch vessels, a large aneurysm diameter, and malapposition at the aneurysm neck significantly affect aneurysm repair after FD stent-only treatment for small IAs.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Resultado do Tratamento , Estudos Retrospectivos , Stents , Angiografia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...