Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Medicine (Baltimore) ; 102(22): e33865, 2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37266640

RESUMO

BACKGROUND: Although many critically ill patients require inter-facility transport for definitive or specialized therapy, the medical equipment required to enhance transport safety remains unclear. This review was performed to summarize the evidence regarding devices used to improve the safety and survival in patients requiring such transport. METHODS: We searched MEDLINE, the Cochrane Central Register of Controlled Trials, and Igaku Chuo Zasshi for randomized controlled trials and observational studies comparing outcomes according to the presence or absence of devices (or new vs conventional devices) during transfer of critically ill patients. RESULTS: Four studies focusing on continuous blood pressure monitoring, extracorporeal membrane oxygenation, pelvic circumferential compression devices, and cuffed tracheal tubes, respectively, met the inclusion criteria. A meta-analysis was not performed because the 4 studies focused on different devices. Near-continuous blood pressure monitoring increased interventions such as intravenous fluid administration during transport, shortened the intensive care unit and hospital lengths of stay, and reduced the incidence of multiple-organ failure compared with use of oscillometric devices. Despite the small sample size and varying severity of illness among the groups, transport of patients with severe respiratory failure under extracorporeal membrane oxygenation resulted in fewer hypoxemic events during transport than transport on conventional ventilators. During transport of patients with pelvic fractures, pelvic belts may help to reduce mortality and the transfusion volume. Cuffed (vs uncuffed) tracheal tubes may reduce post-transport tube replacement events in pediatric patients. CONCLUSION: Studies on devices needed for inter-facility transport of critically ill patients are scarce, but some devices may be beneficial.


Assuntos
Estado Terminal , Oxigenação por Membrana Extracorpórea , Criança , Humanos , Estado Terminal/terapia , Unidades de Terapia Intensiva , Respiração Artificial , Ventiladores Mecânicos
2.
J Intensive Care ; 11(1): 22, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37217973

RESUMO

Transpulmonary pressure is an essential physiologic concept as it reflects the true pressure across the alveoli, and is a more precise marker for lung stress. To calculate transpulmonary pressure, one needs an estimate of both alveolar pressure and pleural pressure. Airway pressure during conditions of no flow is the most widely accepted surrogate for alveolar pressure, while esophageal pressure remains the most widely measured surrogate marker for pleural pressure. This review will cover important concepts and clinical applications for esophageal manometry, with a particular focus on how to use the information from esophageal manometry to adjust or titrate ventilator support. The most widely used method for measuring esophageal pressure uses an esophageal balloon catheter, although these measurements can be affected by the volume of air in the balloon. Therefore, when using balloon catheters, it is important to calibrate the balloon to ensure the most appropriate volume of air, and we discuss several methods which have been proposed for balloon calibration. In addition, esophageal balloon catheters only estimate the pleural pressure over a certain area within the thoracic cavity, which has resulted in a debate regarding how to interpret these measurements. We discuss both direct and elastance-based methods to estimate transpulmonary pressure, and how they may be applied for clinical practice. Finally, we discuss a number of applications for esophageal manometry and review many of the clinical studies published to date which have used esophageal pressure. These include the use of esophageal pressure to assess lung and chest wall compliance individually which can provide individualized information for patients with acute respiratory failure in terms of setting PEEP, or limiting inspiratory pressure. In addition, esophageal pressure has been used to estimate effort of breathing which has application for ventilator weaning, detection of upper airway obstruction after extubation, and detection of patient and mechanical ventilator asynchrony.

4.
J Clin Med ; 10(23)2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34884345

RESUMO

International guidelines recommend targeted temperature management (TTM) to improve the neurological outcomes in adult patients with post-cardiac arrest syndrome (PCAS). However, it still remains unclear if the lower temperature setting (hypothermic TTM) or higher temperature setting (normothermic TTM) is superior for TTM. According to the most recent large randomized controlled trial (RCT), hypothermic TTM was not found to be associated with superior neurological outcomes than normothermic TTM in PCAS patients. Even though this represents high-quality evidence obtained from a well-designed large RCT, we believe that we still need to continue investigating the potential benefits of hypothermic TTM. In fact, several studies have indicated that the beneficial effect of hypothermic TTM differs according to the severity of PCAS, suggesting that there may be a subgroup of PCAS patients that is especially likely to benefit from hypothermic TTM. Herein, we summarize the results of major RCTs conducted to evaluate the beneficial effects of hypothermic TTM, review the recent literature suggesting the possibility that the therapeutic effect of hypothermic TTM differs according to the severity of PCAS, and discuss the potential of individualized TTM.

5.
J Intensive Care ; 9(1): 50, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34399855

RESUMO

BACKGROUND: Patient-ventilator asynchrony (PVA) is a common problem in patients undergoing invasive mechanical ventilation (MV) in the intensive care unit (ICU), and may accelerate lung injury and diaphragm mis-contraction. The impact of PVA on clinical outcomes has not been systematically evaluated. Effective interventions (except for closed-loop ventilation) for reducing PVA are not well established. METHODS: We performed a systematic review and meta-analysis to investigate the impact of PVA on clinical outcomes in patients undergoing MV (Part A) and the effectiveness of interventions for patients undergoing MV except for closed-loop ventilation (Part B). We searched the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, ClinicalTrials.gov, and WHO-ICTRP until August 2020. In Part A, we defined asynchrony index (AI) ≥ 10 or ineffective triggering index (ITI) ≥ 10 as high PVA. We compared patients having high PVA with those having low PVA. RESULTS: Eight studies in Part A and eight trials in Part B fulfilled the eligibility criteria. In Part A, five studies were related to the AI and three studies were related to the ITI. High PVA may be associated with longer duration of mechanical ventilation (mean difference, 5.16 days; 95% confidence interval [CI], 2.38 to 7.94; n = 8; certainty of evidence [CoE], low), higher ICU mortality (odds ratio [OR], 2.73; 95% CI 1.76 to 4.24; n = 6; CoE, low), and higher hospital mortality (OR, 1.94; 95% CI 1.14 to 3.30; n = 5; CoE, low). In Part B, interventions involving MV mode, tidal volume, and pressure-support level were associated with reduced PVA. Sedation protocol, sedation depth, and sedation with dexmedetomidine rather than propofol were also associated with reduced PVA. CONCLUSIONS: PVA may be associated with longer MV duration, higher ICU mortality, and higher hospital mortality. Physicians may consider monitoring PVA and adjusting ventilator settings and sedatives to reduce PVA. Further studies with adjustment for confounding factors are warranted to determine the impact of PVA on clinical outcomes. Trial registration protocols.io (URL: https://www.protocols.io/view/the-impact-of-patient-ventilator-asynchrony-in-adu-bsqtndwn , 08/27/2020).

7.
Ann Am Thorac Soc ; 18(5): 820-829, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33326335

RESUMO

Rationale: Reverse triggering (RT) occurs when respiratory effort begins after a mandatory breath is initiated by the ventilator. RT may exacerbate ventilator-induced lung injury and lead to breath stacking.Objectives: We sought to describe the frequency and risk factors for RT among patients with acute respiratory distress syndrome (ARDS) and identify risk factors for breath stacking.Methods: We performed a secondary analysis of physiologic data from children on synchronized intermittent mandatory pressure-controlled ventilation enrolled in a single-center randomized controlled trial for ARDS. When children had a spontaneous effort on esophageal manometry, waveforms were recorded and independently analyzed by two investigators to identify RT.Results: We included 81,990 breaths from 100 patient-days and 36 patients. Overall, 2.46% of breaths were RTs, occurring in 15/36 patients (41.6%). A higher tidal volume and a minimal difference between neural respiratory rate and set ventilator rate were independently associated with RT (P = 0.001) in multivariable modeling. Breath stacking occurred in 534 (26.5%) of 2,017 RT breaths and in 14 (93.3%) of 15 patients with RT. In multivariable modeling, breath stacking was more likely to occur when total airway Δpressure (peak inspiratory pressure - positive end-expiratory pressure [PEEP]) at the time patient effort began, peak inspiratory pressure, PEEP, and Δpressure were lower and when patient effort started well after the ventilator-initiated breath (higher phase angle) (all P < 0.05). Together, these parameters were highly predictive of breath stacking (area under the curve, 0.979).Conclusions: Patients with higher tidal volume who have a set ventilator rate close to their spontaneous respiratory rate are more likely to have RT, which results in breath stacking >25% of the time.Clinical trial registered with ClinicalTrials.gov (NCT03266016).


Assuntos
Síndrome do Desconforto Respiratório , Lesão Pulmonar Induzida por Ventilação Mecânica , Criança , Humanos , Ventilação com Pressão Positiva Intermitente , Síndrome do Desconforto Respiratório/terapia , Fatores de Risco , Volume de Ventilação Pulmonar , Lesão Pulmonar Induzida por Ventilação Mecânica/prevenção & controle
8.
Crit Care Med ; 49(3): 517-526, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33252373

RESUMO

OBJECTIVES: Inspiratory holds with measures of airway pressure to estimate driving pressure (elastic work) are often limited to patients without respiratory effort. We sought to evaluate if measures of airway pressure during inspiratory holds could be used for patients with spontaneous respiratory effort during mechanical ventilation to estimate the degree of spontaneous effort and elastic work. DESIGN: We compared the direction and degree of change in airway pressure during inspiratory holds versus esophageal pressure through secondary analysis of physiologic data. SETTING: ICUs at Children's Hospital Los Angeles. PATIENTS: Children with pediatric acute respiratory distress syndrome with evidence of spontaneous respiration while on pressure control or pressure support ventilation. INTERVENTIONS: Inspiratory hold maneuvers. MEASUREMENTS AND MAIN RESULTS: From airway pressure, we defined "plateau - peak pressure" as Pmusc, index, which was divided into three categories for analysis (< -1 ["negative"], between -1 and 1 ["neutral"], and > 1 cm H2O ["positive"]). A total of 30 children (age 36.8 mo [16.1-70.3 mo]) from 65 study days, comprising 118 inspiratory holds were included. Pmusc, index was "negative" in 29 cases, was "neutral" in 17 cases, and was "positive" in 72 cases. As Pmusc, index went from negative to neutral to positive, there was larger negative deflection in esophageal pressure -5.0 (-8.2 to 1.9), -5.9 (-7.6 to 4.3), and -10.7 (-18.1 to 7.9) cm H2O (p < 0.0001), respectively. There was a correlation between max negative esophageal pressure and Pmusc, index (r = -0.52), and when Pmusc, index was greater than or equal to 7 cm H2O, the max negative esophageal pressure was greater than 10 cm H2O. There was a stronger correlation between Pmusc, index and markers of elastic work from esophageal pressure (r = 0.84). CONCLUSIONS: The magnitude of plateau minus peak pressure during an inspiratory hold is correlated with the degree of inspiratory effort, particularly for those with high elastic work. It may be useful to identify patients with excessively high effort or high driving pressure.


Assuntos
Unidades de Terapia Intensiva Pediátrica/organização & administração , Respiração com Pressão Positiva/métodos , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/terapia , Desmame do Respirador/métodos , Trabalho Respiratório , Criança , Feminino , Humanos , Los Angeles , Masculino , Resultado do Tratamento
9.
Respir Res ; 20(1): 293, 2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-31870367

RESUMO

BACKGROUND: Ventilator-induced diaphragmatic dysfunction is a serious complication associated with higher ICU mortality, prolonged mechanical ventilation, and unsuccessful withdrawal from mechanical ventilation. Although neurally adjusted ventilatory assist (NAVA) could be associated with lower patient-ventilator asynchrony compared with conventional ventilation, its effects on diaphragmatic dysfunction have not yet been well elucidated. METHODS: Twenty Japanese white rabbits were randomly divided into four groups, (1) no ventilation, (2) controlled mechanical ventilation (CMV) with continuous neuromuscular blockade, (3) NAVA, and (4) pressure support ventilation (PSV). Ventilated rabbits had lung injury induced, and mechanical ventilation was continued for 12 h. Respiratory waveforms were continuously recorded, and the asynchronous events measured. Subsequently, the animals were euthanized, and diaphragm and lung tissue were removed, and stained with Hematoxylin-Eosin to evaluate the extent of lung injury. The myofiber cross-sectional area of the diaphragm was evaluated under the adenosine triphosphatase staining, sarcomere disruptions by electron microscopy, apoptotic cell numbers by the TUNEL method, and quantitative analysis of Caspase-3 mRNA expression by real-time polymerase chain reaction. RESULTS: Physiological index, respiratory parameters, and histologic lung injury were not significantly different among the CMV, NAVA, and PSV. NAVA had lower asynchronous events than PSV (median [interquartile range], NAVA, 1.1 [0-2.2], PSV, 6.8 [3.8-10.0], p = 0.023). No differences were seen in the cross-sectional areas of myofibers between NAVA and PSV, but those of Type 1, 2A, and 2B fibers were lower in CMV compared with NAVA. The area fraction of sarcomere disruptions was lower in NAVA than PSV (NAVA vs PSV; 1.6 [1.5-2.8] vs 3.6 [2.7-4.3], p < 0.001). The proportion of apoptotic cells was lower in NAVA group than in PSV (NAVA vs PSV; 3.5 [2.5-6.4] vs 12.1 [8.9-18.1], p < 0.001). There was a tendency in the decreased expression levels of Caspase-3 mRNA in NAVA groups. Asynchrony Index was a mediator in the relationship between NAVA and sarcomere disruptions. CONCLUSIONS: Preservation of spontaneous breathing using either PSV or NAVA can preserve the cross sectional area of the diaphragm to prevent atrophy. However, NAVA may be superior to PSV in preventing sarcomere injury and apoptosis of myofibrotic cells of the diaphragm, and this effect may be mediated by patient-ventilator asynchrony.


Assuntos
Diafragma/lesões , Diafragma/fisiologia , Suporte Ventilatório Interativo/métodos , Mecânica Respiratória/fisiologia , Ventiladores Mecânicos , Animais , Diafragma/ultraestrutura , Suporte Ventilatório Interativo/efeitos adversos , Coelhos , Distribuição Aleatória , Ventiladores Mecânicos/efeitos adversos
11.
BMC Pulm Med ; 16(1): 119, 2016 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-27519601

RESUMO

BACKGROUND: Venoarterial-venous extracorporeal membrane oxygenation (VAV ECMO) configuration is a combined procedure of extracorporeal membrane oxygenation (ECMO). The proportion of cardiac and respiratory support can be controlled by adjusting arterial and venous return. Therefore, VAV ECMO can be applicable as a bridging therapy in the transition from venoarterial (VA) to venovenous (VV) ECMO. CASE PRESENTATION: We present an 11-year-old girl with chemotherapy-induced myocarditis requiring extracorporeal cardiorespiratory support. She showed progressive hypotension, tachycardia, hyperlactemia, and tachypnea under support of catecholamines. Echocardiography showed severe left ventricular hypokinesis with an ejection fraction of 30 %. She was placed on VA ECMO with a drainage catheter from the right femoral vein (19.5 Fr) and a return catheter to the right femoral artery (16.5 Fr). Extracorporeal circulation was initiated at a blood flow of 2.0 L/min (59 mL/kg/min). On day 31, although cardiac function had improved, persistent pulmonary failure made weaning from VA ECMO difficult. We planned transition from VA ECMO to VAV ECMO to ensure gradual tapering of extracorporeal cardiac support while evaluating cardiopulmonary function. An additional return cannula (13.5 Fr) was inserted from the right internal jugular vein, which was connected to the circuit branch from the original returning cannula. We then gradually shifted the blood from the femoral artery to the right internal jugular vein over 24 h. She was successfully switched from VA to VV ECMO via VAV ECMO. CONCLUSIONS: VAV ECMO might be an option in ensuring oxygenation to the coronary circulation and allowing time to adequately evaluate cardiac function during transition from VA to VV ECMO. Further investigations using larger cohorts are necessary to validate the efficacy of VAV ECMO as a bridging therapy in the transition from VA to VV ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca/terapia , Imunossupressores/efeitos adversos , Miocardite/complicações , Insuficiência Respiratória/terapia , Anemia Aplástica/terapia , Criança , Ciclofosfamida/efeitos adversos , Ciclosporina/efeitos adversos , Ecocardiografia , Feminino , Artéria Femoral , Transplante de Células-Tronco Hematopoéticas , Hemodinâmica , Humanos , Veias Jugulares , Miocardite/induzido quimicamente
12.
Acute Med Surg ; 2(2): 114-116, 2015 04.
Artigo em Inglês | MEDLINE | ID: mdl-29123703

RESUMO

Case: A 61-year-old woman was diagnosed with deep cervical abscess and enlarged mediastinal abscess. These required a protracted period of mechanical ventilation and neck and thoracic drainage surgery with daily wound lavage, necessitating the administration of large amounts of fentanyl and dexmedetomidine. After extubation, fentanyl was discontinued but dexmedetomidine was continued, and she developed hypertension, tachycardia, tachypnea, and hyperthermia within several hours; therefore, she was diagnosed with opioid withdrawal syndrome. Her symptoms failed to improve with either an increased dexmedetomidine dose or a diltiazem infusion for symptomatic management. Ultimately, 20 mg nifedipine was given through a nasogastric tube, which led to a resolution of withdrawal symptoms. Outcome: This is the first case of calcium channel blockers attenuating opioid withdrawal syndrome symptoms in a human. Conclusion: Calcium channel blockers might be alternative therapy to refractory opioid withdrawal syndrome. Case accumulation in the future is expected.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...