Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 61(15): 5837-50, 2016 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-27427184

RESUMO

As well as pre-operative roadmapping by (18)F-Fluoro-2-deoxy-2-D-glucose (FDG) positron emission tomography, intra-operative localization of the tracer is important to identify local margins for less-invasive surgery, especially FDG-guided surgery. The objective of this paper is to develop a laparoscopic Compton camera and system aimed at use for intra-operative FDG imaging for accurate and less-invasive dissections. The laparoscopic Compton camera consists of four layers of a 12-pixel cross-shaped array of GFAG crystals ([Formula: see text] mm(3)) and through silicon via multi-pixel photon counters and dedicated individual readout electronics based on a dynamic time-over-threshold method. Experimental results yielded a spatial resolution of 4 mm (FWHM) for a 10 mm working distance and an absolute detection efficiency of 0.11 cps kBq(-1), corresponding to an intrinsic detection efficiency of ∼0.18%. In an experiment using a NEMA-like well-shaped FDG phantom, a [Formula: see text] mm cylindrical hot spot was clearly obtained even in the presence of a background distribution surrounding the Compton camera and the hot spot. We successfully obtained reconstructed images of a resected lymph node and primary tumor ex vivo after FDG administration to a patient having esophageal cancer. These performance characteristics indicate a new possibility of FDG-directed surgery by using a Compton camera intra-operatively.


Assuntos
Laparoscopia/instrumentação , Fótons , Tomografia por Emissão de Pósitrons/instrumentação , Cirurgia Assistida por Computador/instrumentação , Endoscópios , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador/métodos , Laparoscopia/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Cirurgia Assistida por Computador/métodos
2.
Rev Sci Instrum ; 85(11): 11E804, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430369

RESUMO

A 12 × 12 pixel detector has been developed and used in a laboratory experiment for lost fast-ion diagnostics. With gamma rays in the MeV range originating from nuclear reactions (9)Be(α, nγ)(12)C, (9)Be(d, nγ)(12)C, and (12)C(d, pγ)(13)C, a high purity germanium (HPGe) detector measured a fine-energy-resolved spectrum of gamma rays. The HPGe detector enables the survey of background-gamma rays and Doppler-shifted photo peak shapes. In the experiments, the pixel detector produces a gamma-ray image reconstructed from the energy spectrum obtained from total photon counts of irradiation passing through the detector's lead collimator. From gamma-ray image, diagnostics are able to produce an analysis of the fast ion loss onto the first wall in principle.

3.
Tohoku J Exp Med ; 132(4): 385-8, 1980 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7256724

RESUMO

A case is reported of a 5-year-old boy with Lowe syndrome. The patient was unusual in that he had only mild and transient acidosis with no rickets. The corneal opacities in the parents suggest that this disease might be autosomal recessive.


Assuntos
Síndrome Oculocerebrorrenal/sangue , Erros Inatos do Transporte Tubular Renal/sangue , Bicarbonatos/sangue , Pré-Escolar , Humanos , Concentração de Íons de Hidrogênio , Masculino , Fósforo/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...