1.
Australas Phys Eng Sci Med ; 42(3): 811-818, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31410839

RESUMO

The nondestructive dosimetry achieved with electron paramagnetic resonance (EPR) dosimetry facilitates repetitive recording by the same dosimeter to increase the reliability of data. In precedent studies, solid paraffin was needed as a binder material to make the lithium formate monohydrate (LFM) EPR dosimeter stable and nonfragile; however, its use complicates dosimetry. This study proposes a newly designed pure LFM EPR dosimeter created by inserting LFM into a 3D-printed container. Dosimetric characteristics of the LFM EPR dosimeter and container, such as reproducibility, linearity, energy dependence, and angular dependence, were evaluated and verified through a radiation therapy planning system (RTPS). The LFM EPR dosimeters were irradiated using a clinical linear accelerator. The EPR spectra of the dosimeters were acquired using a Bruker EMX EPR spectrometer. Through this study, it was confirmed that there is no tendency in the EPR response of the container based on irradiation dose or radiation energy. The results show that the LFM EPR dosimeters have a highly sensitive dose response with good linearity. The energy dependence across each photon and electron energy range seems to be negligible. Based on these results, LFM powder in a 3D-printed container is a suitable option for dosimetry of radiotherapy. Furthermore, the LFM EPR dosimeter has considerable potential for in vivo dosimetry and small-field dosimetry via additional experiments, owing to its small effective volume and highly sensitive dose response compared with a conventional dosimeter.


Assuntos
Formiatos/química , Impressão Tridimensional , Radiometria , Radioterapia , Espectroscopia de Ressonância de Spin Eletrônica , Elétrons , Fótons , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
2.
PLoS One ; 12(9): e0185082, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28926610

RESUMO

OBJECTIVE: Various methods for radiation-dose calculation have been investigated over previous decades, focusing on the use of magnetic resonance imaging (MRI) only. The bulk-density-assignment method based on manual segmentation has exhibited promising results compared to dose-calculation with computed tomography (CT). However, this method cannot be easily implemented in clinical practice due to its time-consuming nature. Therefore, we investigated an automatic anatomy segmentation method with the intention of providing the proper methodology to evaluate synthetic CT images for a radiation-dose calculation based on MR images. METHODS: CT images of 20 brain cancer patients were selected, and their MR images including T1-weighted, T2-weighted, and PETRA were retrospectively collected. Eight anatomies of the patients, such as the body, air, eyeball, lens, cavity, ventricle, brainstem, and bone, were segmented for bulk-density-assigned CT image (BCT) generation. In addition, water-equivalent CT images (WCT) with only two anatomies-body and air-were generated for a comparison with BCT. Histogram comparison and gamma analysis were performed by comparison with the original CT images, after the evaluation of automatic segmentation performance with the dice similarity coefficient (DSC), false negative dice (FND) coefficient, and false positive dice (FPD) coefficient. RESULTS: The highest DSC value was 99.34 for air segmentation, and the lowest DSC value was 73.50 for bone segmentation. For lens segmentation, relatively high FND and FPD values were measured. The cavity and bone were measured as over-segmented anatomies having higher FPD values than FND. The measured histogram comparison results of BCT were better than those of WCT in all cases. In gamma analysis, the averaged improvement of BCT compared to WCT was measured. All the measured results of BCT were better than those of WCT. Therefore, the results of this study show that the introduced methods, such as histogram comparison and gamma analysis, are valid for the evaluation of the synthetic CT generation from MR images. CONCLUSIONS: The image similarity results showed that BCT has superior results compared to WCT for all measurements performed in this study. Consequently, more accurate radiation treatment for the intracranial regions can be expected when the proper image similarity evaluation introduced in this study is performed.


Assuntos
Neoplasias Encefálicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/normas , Algoritmos , Osso e Ossos/anatomia & histologia , Osso e Ossos/diagnóstico por imagem , Encéfalo/anatomia & histologia , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/normas , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
PLoS One ; 10(3): e0119937, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25807544

RESUMO

OBJECTIVE: To investigate the usefulness of the 3DVH software with an ArcCHECK 3D diode array detector in newly designed plans with various target sizes. METHODS: The isocenter dose was measured with an ion-chamber and was compared with the planned and 3DVH predicted doses. The 2D gamma passing rates were evaluated at the diode level by using the ArcCHECK detector. The 3D gamma passing rates for specific regions of interest (ROIs) were also evaluated by using the 3DVH software. Several dose-volume histograms (DVH)-based predicted metrics for all structures were also obtained by using the 3DVH software. RESULTS: The isocenter dose deviation was <1% in all plans except in the case of a 1 cm target. Besides the gamma passing rate at the diode level, the 3D gamma passing rate for specific ROIs tended to decrease with increasing target size; this was more noticeable when a more stringent gamma criterion was applied. No correlation was found with the gamma passing rates and the DVH-based metrics especially in the ROI with high-dose gradients. CONCLUSIONS: Delivery quality assurance by using 3DVH and ArcCHECK can provide substantial information through a simple and easy approach, although the accuracy of this system should be judged cautiously.


Assuntos
Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Software
4.
PLoS One ; 9(10): e110746, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25337700

RESUMO

OBJECTIVE: Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D) printer and evaluated its feasibility for radiotherapy. METHODS: We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. RESULTS: The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. CONCLUSIONS: A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.


Assuntos
Neoplasias/radioterapia , Humanos , Imagens de Fantasmas , Impressão Tridimensional , Dosagem Radioterapêutica , Radioterapia Assistida por Computador
5.
Radiat Oncol ; 8: 284, 2013 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-24305109

RESUMO

BACKGROUND: To create an arc therapy plan, certain current general calculation algorithms such as pencil-beam calculation (PBC) are based on discretizing the continuous arc into multiple fields to simulate an arc. The iPlan RT™ treatment planning system incorporates not only a PBC algorithm, but also a more recent Monte Carlo calculation (MCC) algorithm that does not need beam discretization. The objective of this study is to evaluate the dose differences in a homogenous phantom between PBC and MCC by using a three-dimensional (3D) diode array detector (ArcCHECK™) and 3DVH software. METHODS: A cylindrically shaped 'target' region of interest (ROI) and a 'periphery ROI' surrounding the target were designed. An arc therapy plan was created to deliver 600 cGy to the target within a 350° rotation angle, calculated using the PBC and MCC algorithms. The radiation doses were measured by the ArcCHECK, and reproduced by the 3DVH software. Through this process, we could compare the accuracy of both algorithms with regard to the 3D gamma passing rate (for the entire area and for each ROI). RESULTS: Comparing the PBC and MCC planned dose distributions directly, the 3D gamma passing rates for the entire area were 97.7% with the gamma 3%/3 mm criterion. Comparing the planned dose to the measured dose, the 3D gamma passing rates were 98.8% under the PBC algorithm and 100% under the MCC algorithm. The difference was statistically significant (p = 0.034). Furthermore the gamma passing rate decreases 7.5% in the PBC when using the 2%/2 mm criterion compared to only a 0.4% decrease under the MCC. Each ROI as well as the entire area showed statistically significant higher gamma passing rates under the MCC algorithm. The failure points that did not satisfy the gamma criteria showed a regular pattern repeated every 10°. CONCLUSIONS: MCC showed better accuracy than the PBC of the iPlan RT in calculating the dose distribution in arc therapy, which was validated with the ArcCHECK and the 3DVH software. This may suggest that the arc step of 10° is too large in the PBC algorithm in the iPlan RT.


Assuntos
Neoplasias/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Imageamento Tridimensional , Método de Monte Carlo , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Software , Tomografia Computadorizada por Raios X