Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Physiol Meas ; 39(6): 065006, 2018 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-29767634

RESUMO

OBJECTIVE: The time signature of tracheal noise in the 200-2000 Hz frequency band recorded during a forced expiratory manoeuvre (FETa) is a promising tool for diagnosis of bronchial obstructions. FETa is typically registered using a microphone with a stethoscope head placed on the neck over the trachea (stethoscope sensor). We studied basic time and spectral parameters of forced expiratory tracheal noises with a microphone placed near the mouth (lapel microphone, outside the flow of exhaled air) and compared these with measurements via stethoscope sensor, with the aim of providing patient home monitoring via standard personal computer facilities. APPROACH: FETa, 200 Hz band pass times, and frequency responses of signals recorded simultaneously with both sensors were analysed in a sample of 24 healthy volunteers. MAIN RESULTS: Averaged real transfer function of signals from a stethoscope sensor and a lapel microphone in the frequency range 200-1800 Hz was characterized by a slope of -7.2 dB/octave. This is near the slope of -6 dB/octave predicted via theoretical models of both sensors. The lapel microphone and stethoscope sensor were not interchangeable regarding spectral characteristics of forced expiratory tracheal noises. However, FETa measurements in healthy volunteers via stethoscope sensor and lapel microphone showed no significant differences according to U-Mann-Whitney test for independent samples. SIGNIFICANCE: The ability to measure FETa successfully with a lapel microphone placed near the mouth was experimentally demonstrated in healthy volunteers. Additional studies are needed to verify whether FETa measured near the mouth is acceptable for monitoring pulmonary status in patients with asthma or chronic obstructive pulmonary disease.


Assuntos
Expiração/fisiologia , Cabeça , Ruído , Estetoscópios , Traqueia/fisiologia , Vestuário , Humanos
2.
Fiziol Cheloveka ; 40(1): 96-100, 2014.
Artigo em Russo | MEDLINE | ID: mdl-25272774

RESUMO

Dynamics of duration of tracheal forced expiratory noises in a group of volunteers was studied before, during and after 520-days confinement. The duration did not change in most volunteers. Two volunteers demonstrated significant changes of tracheal sounds duration and some spirometric parameters. Increase in duration of tracheal forced expiratory noises and decrease in spirometric parameters reveal ventilatory impairment of obstructive type. Analysis of duration of tracheal forced expiratory noises dynamics during prolonged confinement proves to be a sensitive technique to test ventilatory function changes.


Assuntos
Expiração/fisiologia , Volume Expiratório Forçado/fisiologia , Traqueia/fisiologia , Adulto , Humanos , Masculino , Ruído , Espirometria
3.
Fiziol Cheloveka ; 38(1): 92-8, 2012.
Artigo em Russo | MEDLINE | ID: mdl-22567842

RESUMO

In previous study it was shown that duration of tracheal forced expiratory noises is promising to reveal negative changes of lung function after dive. The objective is a study of parameters of tracheal forced expiratory noises in changed gas media. The first experiment involved 25 volunteers (22-60 years), performed forced exhalation under normal pressure with air, oxygen-helium and oxygen-krypton mixtures. The second experiment in the chamber involved 6 volunteers (25-46 years), which performed forced exhalation with air under normal pressure (0.1 MPa), and under elevated pressure 0.263 MPa with air and oxygen-helium mixture. In the first experiment the direct linear dependence on gas density was found for forced expiratory noises common duration in the band of 200-2000 Hz and for its durations in narrow 200-Hz bands, excluding high frequency range 1400-2000 Hz. In the second experiment a significant reversed dependence of high frequency durations and spectral energies in 200-Hz bands (1600-2000 Hz) on adiabatic gas compressibility. Individual dynamics of common duration of tracheal forced expiratory noises under model dive of 16.3 m (0.263 MPa) is more then the diagnostic threshold of this parameter for lung function decrease, previously obtained for divers under normal pressure.


Assuntos
Mergulho/fisiologia , Expiração/fisiologia , Pulmão/fisiologia , Respiração , Acústica , Adulto , Ar , Hélio , Humanos , Criptônio , Masculino , Pessoa de Meia-Idade , Oxigênio , Pressão
4.
Radiats Biol Radioecol ; 43(3): 370-4, 2003.
Artigo em Russo | MEDLINE | ID: mdl-12882000

RESUMO

Electronic homeopathic copies (EHC) are remedies prepared without traditional dilution/potentiation but by means of so-called "imprinting" of initial substance to water (or other carriers) with the help of M. Ray's devices. EHC are interpreted by modern homeopathic medicine as functional analogs of biologically active substances (BAS) in supersmall doses (SSD). The authors have undertaken 3 blind randomised experiments concerning BAS aqueous solution of fertilizer biohumus, its EHC and placebo influence on tomatoes' sprouts development. Filtered and intermixed water have been encapsulated in 1.5-liter polyethylene containers. The solution of fertilizer has been prepared in accordance with the instruction. EHC has been "transferred" from the concentrated fertilizer with the help of Simulator (Metabolics, GB) apparatus. "Deleting" of information have been made for placebo. Seed of tomatoes (kind "Yasniye") have been pre-soaked in preparations and landed in accordingly numbered plastic boxes (97 x 15 x 14 sm) by 40-44 plants in each one. The seedbed was from one well intermixed portion. The plants were top-dressed by preparations (200-300 ml) one time per week. The boxes were exposed in one room (rotation was made twice per week). The plants have been cut up on the 38th day from pre-soaking. The height of a green part and its mass have been measured for each plant. The differences between independent samples (preparations studied) have been estimated. The differences between EHC and placebo have appeared to be reliable, in the first experiment (p < 2 x 10(-4)--mass, p < 10(-9)--height), in the second one (p = 0.014--mass), in the third one (p < 3 x 10(-6)--mass, p = 0.028--height) The results obtained verify a reality of EHC phenomenon. Thus it is quite within reason to suggest an existence of uniform physical (instead of chemical) mechanism of BAS's EHC/SSD structuring and acting on biological objects.


Assuntos
Eletroquímica/métodos , Fertilizantes , Solanum lycopersicum/crescimento & desenvolvimento , Eletroquímica/instrumentação , Formulários Homeopáticos como Assunto , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA