Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 90(19): 11219-11223, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30130092

RESUMO

Improvements in the responses of semiconductor gas sensors and reductions in their detection limits toward volatile organic compounds (VOCs) are required in order to facilitate the simple detection of diseases, such as cancer, through human-breath analysis. In this study, we introduce a heater-switching, pulse-driven, micro gas sensor composed of a microheater and a sensor electrode fabricated with Pd-SnO2-clustered nanoparticles as the sensing material. The sensor was repeatedly heated and allowed to cool by the application of voltage to the microheater; the VOC gases penetrate into the interior of the sensing layer during its unheated state. Consequently, the utility factor of the pulse-driven sensor was greater than that of a conventional, continuously heated sensor. As a result, the response of the sensor to toluene was enhanced; indeed, the sensor responded to toluene at levels of 1 ppb. In addition, according to the relationship between its response and concentration of toluene, the pulse-driven sensor in this report can detect toluene at concentrations of 200 ppt and even lower. Therefore, the combination of a pulse-driven microheater and a suitable material designed to detect toluene resulted in improved sensor response, and facilitated ppt-level toluene detection. This sensor may play a key role in the development of medical diagnoses based on human breath.

2.
Anal Chem ; 87(16): 8407-15, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26196499

RESUMO

Real-time monitoring of specific gas concentrations with a compact and portable gas sensing device is required to sense potential health risk and danger from toxic gases. For such purposes, we developed an ultrasmall gas sensor device, where a micro sensing film was deposited on a micro heater integrated with electrodes fabricated by the microelectromechanical system (MEMS) technology. The developed device was operated in a pulse-heating mode to significantly reduce the heater power consumption and make the device battery-driven and portable. Using clustered Pd/SnO2 nanoparticles, we succeeded in introducing mesopores ranging from 10 to 30 nm in the micro gas sensing film (area: ϕ 150 µm) to detect large volatile organic compounds (VOCs). The micro sensor showed quick, stable, and high sensor responses to toluene at ppm (parts per million) concentrations at 300 °C even by operating the micro heater in a pulse-heating mode where switch-on and -off cycles were repeated at one-second intervals. The high performance of the micro sensor should result from the creation of efficient diffusion paths decorated with Pd sensitizers by using the clustered Pd/SnO2 nanoparticles. Hence we demonstrate that our pulse-driven micro sensor using nanostructured oxide materials holds promise as a battery-operable, portable gas sensing device.


Assuntos
Técnicas Eletroquímicas/métodos , Gases/análise , Chumbo/química , Nanopartículas Metálicas/química , Compostos de Estanho/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Nanopartículas Metálicas/ultraestrutura , Sistemas Microeletromecânicos , Porosidade , Tolueno/análise , Compostos Orgânicos Voláteis/análise
3.
ACS Appl Mater Interfaces ; 6(7): 5319-26, 2014 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-24635838

RESUMO

Gas sensing with nanosized oxide materials is attracting much attention because of its promising capability of detecting various toxic gases at very low concentrations. In this study, using clustered SnO2 nanoparticles formed by controlled particle aggregation, we fabricated highly sensitive gas sensing films to detect large gas molecules such as toluene. A hydrothermal method using stanic acid (SnO2·nH2O) gel as a precursor produced monodispersed SnO2 nanoparticles of ca. 5 nm at pH 10.6. Decreasing the solution pH to 9.3 formed SnO2 clusters of ca. 45 nm that were assemblies of the monodispersed nanoparticles, as determined by dynamic light scattering, X-ray diffraction, and transmission electron microscopy analyses. Porous gas sensing films were successfully fabricated by a spin-coating method using the clustered nanoparticles due to the loose packing of the larger aggregated particles. The sensor devices using the porous films showed improved sensor responses (sensitivities) to H2 and CO at 300 °C. The enhanced sensitivity resulted from an increase in the film's porosity, which promoted the gas diffusivity of the sensing films. Pd loading onto the clustered nanoparticles further upgraded the sensor response due to catalytic and electrical sensitization effects of Pd. In particular, the Pd-loaded SnO2 nanoparticle clusters showed excellent sensitivity to toluene, able to detect it at down to low ppb levels.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...