1.
PNAS Nexus ; 3(2): pgae070, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38384383

RESUMO

The small intestine and liver play important role in determining oral drug's fate. Both organs are also interconnected through enterohepatic circulation, which imply there are crosstalk through circulating factors such as signaling molecules or metabolites that may affect drug metabolism. Coculture of hepatocytes and intestinal cells have shown to increase hepatic drug metabolism, yet its crosstalk mechanism is still unclear. In this study, we aim to elucidate such crosstalk by coculturing primary human hepatocytes harvested from chimeric mouse (PXB-cells) and iPSc-derived intestinal cells in a microphysiological systems (MPS). Perfusion and direct oxygenation from the MPS were chosen and confirmed to be suitable features that enhanced PXB-cells albumin secretion, cytochrome P450 (CYP) enzymes activity while also maintaining barrier integrity of iPSc-derived intestine cells. Results from RNA-sequencing showed significant upregulation in gene ontology terms related to fatty acids metabolism in PXB-cells. One of such fatty acids, arachidonic acid, enhanced several CYP enzyme activity in similar manner as coculture. From the current evidences, it is speculated that the release of bile acids from PXB-cells acted as stimuli for iPSc-derived intestine cells to release lipoprotein which was ultimately taken by PXB-cells and enhanced CYP activity.

2.
Lab Chip ; 24(3): 408-421, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-38131210

RESUMO

Microphysiological systems (MPS) offer an alternative method for culturing cells on microfluidic platforms to model organ functions in pharmaceutical and medical sciences. Although MPS hardware has been proposed to maintain physiological organ function through perfusion culture, no existing MPS can automatically assess cell morphology and conditions online to observe cellular dynamics in detail. Thus, with this study, we aimed to establish a practical strategy for automating cell observation and improving cell evaluation functions with low temporal resolution and throughput in MPS experiments. We developed a versatile standalone cell culture microfluidic device (SCCMD) that integrates microfluidic chips and their peripherals. This device is compliant with the ANSI/SLAS standards and has been seamlessly integrated into an existing automatic cell imaging system. This integration enables automatic cell observation with high temporal resolution in MPS experiments. Perfusion culture of human kidney proximal tubule epithelial cells using the SCCMD improves cell function. By combining the proximal tubule MPS with an existing cell imaging system, nephrotoxicity studies were successfully performed to automate morphological and material permeability evaluation. We believe that the concept of building the ANSI/SLAS-compliant-sized MPS device proposed herein and integrating it into an existing automatic cell imaging system for the online measurement of detailed cell dynamics information and improvement of throughput by automating observation operations is a novel potential research direction for MPS research.


Assuntos
Técnicas de Cultura de Células , Sistemas Microfisiológicos , Humanos , Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Células Epiteliais
3.
Micromachines (Basel) ; 12(9)2021 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-34577652

RESUMO

Microphysiological systems (MPSs), including organ-on-a-chip (OoC), have attracted attention as a novel method for estimating the effects and side effects of drugs in drug discovery. To reproduce the dynamic in vivo environment, previous MPSs were connected to pump systems to perfuse culture medium. Therefore, most MPSs are not user-friendly and have poor throughput. We aimed to develop a kinetic pump integrated microfluidic plate (KIM-Plate) by applying the stirrer-based micropump to an open access culture plate to improve the usability of MPSs. The KIM-Plate integrates six multiorgan MPS (MO-MPS) units and meets the ANSI/SBS microplate standards. We evaluated the perfusion function of the kinetic pump and found that the KIM-Plate had sufficient agitation effect. Coculture experiments with PXB cells and hiPS intestinal cells showed that the TEER of hiPS intestinal cells and gene expression levels related to the metabolism of PXB cells were increased. Hence, the KIM-Plate is an innovative tool for the easy coculture of highly conditioned cells that is expected to facilitate cell-based assays in the fields of drug discovery and biology because of its usability and high throughput nature.

4.
Sci Rep ; 11(1): 5437, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33686099

RESUMO

Examining intestine-liver interactions is important for achieving the desired physiological drug absorption and metabolism response in in vitro drug tests. Multi-organ microphysiological systems (MPSs) constitute promising tools for evaluating inter-organ interactions in vitro. For coculture on MPSs, normal cells are challenging to use because they require complex maintenance and careful handling. Herein, we demonstrated the potential of coculturing normal cells on MPSs in the evaluation of intestine-liver interactions. To this end, we cocultured human-induced pluripotent stem cell-derived intestinal cells and fresh human hepatocytes which were isolated from PXB mice with medium circulation in a pneumatic-pressure-driven MPS with pipette-friendly liquid-handling options. The cytochrome activity, albumin production, and liver-specific gene expressions in human hepatocytes freshly isolated from a PXB mouse were significantly upregulated via coculture with hiPS-intestinal cells. Our normal cell coculture shows the effects of the interactions between the intestine and liver that may occur in vivo. This study is the first to demonstrate the coculturing of hiPS-intestinal cells and fresh human hepatocytes on an MPS for examining pure inter-organ interactions. Normal-cell coculture using the multi-organ MPS could be pursued to explore unknown physiological mechanisms of inter-organ interactions in vitro and investigate the physiological response of new drugs.


Assuntos
Hepatócitos/metabolismo , Células-Tronco Pluripotentes Induzidas/metabolismo , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Animais , Técnicas de Cocultura , Avaliação Pré-Clínica de Medicamentos , Hepatócitos/citologia , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Camundongos , Pressão
5.
Micromachines (Basel) ; 11(7)2020 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-32708814

RESUMO

Numerous in vitro studies have been conducted in conventional static cell culture systems. However, most of the results represent an average response from a population of cells regardless of their local microenvironment. A microfluidic probe is a non-contact technology that has been widely used to perform local chemical stimulation within a restricted space, providing elaborated modulation and analysis of cellular responses within the microenvironment. Although microfluidic probes developed earlier have various potential applications, the two-dimensional structure can compromise their functionality and flexibility for practical use. In this study, we developed a three-dimensional microfluidic probe integrated device equipped with vertically oriented microchannels to overcome crucial challenges and tested the potential utility of the device in biological research. We demonstrated that the device tightly regulated spatial diffusion of a fluorescent molecule, and the flow profile predicted by simulation replicated the experimental results. Additionally, the device modulated the physiological Ca2+ response of cells within the restricted area by altering the local and temporal concentrations of biomolecules such as ATP. The novel device developed in this study may provide various applications for biological studies and contribute to further understanding of molecular mechanisms underlying cellular physiology.

6.
Biomicrofluidics ; 14(4): 044108, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34992705

RESUMO

In drug discovery, the emergence of unexpected toxicity is often a problem resulting from a poor understanding of the pharmacokinetics of drug-drug interactions (DDI). Organ-on-a-chip (OoC) has been proposed as an in vitro model to evaluate drug efficacy and toxicity in pharmacology, but it has not been applied to DDI studies yet. In this study, we aim to evaluate whether organ-on-a-chip technologies can be applied to DDI studies. To assess the usefulness of OoC for DDI studies, we proposed a multi-organ-on-a-chip (MOoC) with a liver part as the metabolic model and a cancer part as the drug target model, and a pharmacokinetic-pharmacodynamic (PK-PD) model describing the MOoC. An anticancer prodrug, CPT-11, was used to evaluate the drug efficacy of the metabolite in the liver part of the MOoC. To evaluate DDI using the MOoC, the inhibitory effect of simvastatin and ritonavir on the metabolism of CPT-11 was tested. The DDI estimation method was evaluated by comparing the results of the concomitant administration experiment using the MOoC and the results of simulation using the proposed PK-PD model with the estimated parameters. The results were similar, suggesting that the combination of the PK-PD model and the MOoC is a useful way to predict DDI. We conclude that OoC technologies could facilitate a better understanding of pharmacokinetic mechanisms with DDI.

7.
PLoS One ; 11(12): e0168158, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27930750

RESUMO

Cell-cell interactions play an important role in the development and function of multicellular organisms. To investigate these interactions in detail, it is necessary to evaluate the behavior of a cell population when the minimum number of cells in the population is stimulated by some chemical factors. We propose a microfluidic device integrated with microfluidic probe (MFP) functionality; this device is capable of imparting a chemical stimulus to cells within a microenvironment, for cell-based assays. The device contains MFP channels at the walls of the cell culture microchannels, and it can control a localized chemical stimulation area at the scale of a single cell to a few cells using MFP fluid control in a microspace. The results of a finite element method-based simulation indicated that it is possible to control the chemical stimulation area at the scale of a single cell to a few cells by optimizing the MFP channel apex width and the flow ratio. In addition, localized cell staining was demonstrated successfully using a spatial chemical stimulus. We confirmed the device functionality as a novel cell-based assay tool. We succeeded in performing localized cell collection using this method, which suggested that the single cell analysis of a cell monolayer that is subjected to a specific chemical stimulus is possible. The method proposed in this paper can contribute significantly to the fields of cell biology and drug development.


Assuntos
Células Cultivadas/química , Técnicas Analíticas Microfluídicas/instrumentação , Animais , Células CHO/química , Células CHO/efeitos dos fármacos , Células Cultivadas/efeitos dos fármacos , Microambiente Celular , Desenho Assistido por Computador , Cricetulus , Análise de Elementos Finitos , Técnicas Analíticas Microfluídicas/métodos , Rodaminas/farmacologia , Tripsina/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...