Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Jpn J Infect Dis ; 76(2): 162-166, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-36575023

RESUMO

Biosafety level 4 (BSL-4) laboratories are necessary to study microorganisms that are highly pathogenic to humans and have no prevention or therapeutic measures. Currently, most BSL-4 facilities have suit-type laboratories to conduct experiments on highly pathogenic microorganisms. In 2021, the first Japanese suit-type BSL-4 laboratory was constructed at Nagasaki University. Positive pressure protection suit (PPPS) is a primary barrier that protects and isolates laboratory workers from pathogens and the laboratory environment. Here, we developed a novel PPPS originally designed to be used in the Nagasaki BSL-4 laboratory. We modified several parts of a domestic chemical protective suit, including its front face shield, cuff, and air supply hose, for safe handling of microbiological agents. The improved suit, PS-790BSL4-AL, showed resistance to several chemicals, including quaternary ammonium disinfectant, and did not show any permeation against blood and phages. To validate the suit's integrity, we also established an airtight test that eliminated individual differences for quantitative testing. In conclusion, our developed suit performs sufficiently as a primary barrier and allows for the safe handling of pathogens in our new BSL-4 laboratory.


Assuntos
Contenção de Riscos Biológicos , Laboratórios , Humanos , Japão
2.
Biocontrol Sci ; 25(1): 9-16, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32173667

RESUMO

Healthcare workers should wear appropriate personal protective clothing (PPC) on assuming the risk of exposure to various pathogens. Therefore, it is important to understand PPC performance against pathogen penetration. Currently, standard methods to evaluate and classify the penetration resistance of PPC fabrics with pressure using synthetic blood or phi-X174 phage have been established by the International Organization for Standardization (ISO). However, the penetration of viral liquid drops (VLDrop) on the PPC without pressure is also a major exposure route and more realistic, necessitating further studies. Here, we evaluated the penetration resistance against VLDrop without pressure using phi-X174 phage on woven and nonwoven fabrics of commercially available PPC classified by the ISO, and analyzed in detail the penetration behaviors of VLDrop by quantifying the phage amounts in leak-through and migration into test fabrics. Our results showed that some nonwoven test fabrics had nearly the same penetration resistance against VLDrop, even if the ISO resistance class differed. Furthermore, the results revealed that the amount of leakage through the fabrics was correlated with the migration amount into the fabric, which was related to fluid-repellency of fabrics, suggesting the effectiveness for penetration resistance. Our study may facilitate more appropriate selection for PPC against pathogen penetration.


Assuntos
Equipamento de Proteção Individual/virologia , Roupa de Proteção/virologia , Têxteis/virologia , Vírus/patogenicidade , Bacteriófago phi X 174/patogenicidade , Teste de Materiais/métodos
3.
Front Public Health ; 7: 121, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31179258

RESUMO

Personal protective gowns and coveralls are classified based on barrier efficiency that validates protection from fluid penetration under certain pressures. Materials standardized in this system have been found suitable for emergency medical practices confronting highly contagious diseases. Nevertheless, adhesion of blood, and body fluids from virus-infected patients to the surface of protective clothing still imposes a risk of pathogen transmission in the process of doffing, or undressing. We performed a small-scale experiment to test the possibility of infectious virus carryover on the surface of different fabrics used in commercially available protective gowns. Application of a lentivirus vector that expresses green fluorescent protein allowed easy monitoring of infectious viral loads on fabrics. Results indicate that fabrics of level-3 surgical gowns serve better to reduce virus transmission compared to fabrics of chemical protective clothing with the same or higher barrier efficiency. Analysis of sliding angles provided indexes of fluid repellency, which were inversely related to virus carryover potentials. Droplets of infectious body fluids may easily roll off fabrics with water-repellent finishing. Thus, virus carryover is a measurable risk factor to be considered for better choice of personal protective clothing.

4.
Biocontrol Sci ; 23(2): 61-69, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29910210

RESUMO

 Exact evaluation of the performance of surgical masks and biohazard protective clothing materials against pathogens is important because it can provide helpful information that healthcare workers can use to select suitable materials to reduce infection risk. Currently, to evaluate the protective performance of nonwoven fabrics used in surgical masks against viral aerosols, a non-standardized test method using phi-X174 phage aerosols is widely performed because actual respiratory viruses pose an infection risk during testing and the phage is a safe virus to humans. This method of using a phage is simply modified from a standard method for evaluation of filter performance against bacterial aerosols using Staphylococcus aureus, which is larger than virus particles. However, it is necessary to perform such evaluations based on the size of the actual pathogen particles. Thus, we developed a new method that can be performed safely using inactivated viral particles and can quantitate the influenza virus in aerosols by antigen-capture ELISA (Shimasaki et al., 2016a) . In this study, we used three different microbial aerosols of phi-X174 phage, influenza virus, and S. aureus and tested the filter efficiency by capturing microbial aerosols for two medical nonwoven fabrics. We compared the filter efficiency against each airborne microbe to analyze the dependency of filter efficiency on the microbial particle size. Our results showed that against the three types of spherical microbe particles, the filter efficiencies against influenza virus particles were the lowest and those against phi-X174 phages were the highest for both types of nonwoven fabrics. The experimental results mostly corresponded with theoretical calculations. We conclude that the filter efficiency test using the phi-X174 phage aerosol may overestimate the protective performance of nonwoven fabrics with filter structure compared to that against real pathogens such as the influenza virus.


Assuntos
Aerossóis , Filtros de Ar , Microbiologia do Ar , Filtração/métodos , Máscaras , Roupa de Proteção , Têxteis , Bacteriófago phi X 174/isolamento & purificação , Humanos , Orthomyxoviridae/isolamento & purificação , Staphylococcus aureus/isolamento & purificação
5.
Biocontrol Sci ; 23(1): 7-15, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29576594

RESUMO

 Recent studies have investigated the efficacy of air-cleaning products against pathogens in the air. A standard method to evaluate the reduction in airborne viruses caused by an air cleaner has been established using a safe bacteriophage instead of pathogenic viruses; the reduction in airborne viruses is determined by counting the number of viable airborne phages by culture, after operating the air cleaner. The reduction in the number of viable airborne phages could be because of "physical decrease" or "inactivation". Therefore, to understand the mechanism of reduction correctly, an analysis is required to distinguish between physical decrease and inactivation. The purpose of this study was to design an analysis to distinguish between the physical decrease and inactivation of viable phi-X174 phages in aerosols. We established a suitable polymerase chain reaction (PCR) system by selecting an appropriate primer-probe set for PCR and validating the sensitivity, linearity, and specificity of the primer-probe set to robustly quantify phi-X174-specific airborne particles. Using this quantitative PCR system and culture assay, we performed a behavior analysis of the phage aerosol in a small chamber (1 m3) at different levels of humidity, as humidity is known to affect the number of viable airborne phages. The results revealed that the reduction in the number of viable airborne phages was caused not only by physical decrease but also by inactivation under particular levels of humidity. Our study could provide an advanced analysis to differentiate between the physical decrease and inactivation of viable airborne phages.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Bacteriófagos , Vírion , Bactérias/virologia , RNA Viral , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Ensaio de Placa Viral , Replicação Viral
6.
Ind Health ; 55(6): 521-528, 2017 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-28978815

RESUMO

For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task.


Assuntos
Substitutos Sanguíneos , Teste de Materiais/métodos , Equipamento de Proteção Individual/normas , Humanos , Exposição Ocupacional/prevenção & controle
7.
Biocontrol Sci ; 21(3): 141-52, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27667519

RESUMO

To prevent nosocomial infections caused by even either Ebola virus or methicillin-resistant Staphylococcus aureus (MRSA), healthcare workers must wear the appropriate protective clothing which can inhibit contact transmission of these pathogens. Therefore, it is necessary to evaluate the performance of protective clothing for penetration resistance against infectious agents. In Japan, some standard methods were established to evaluate the penetration resistance of protective clothing fabric materials under applied pressure. However, these methods only roughly classified the penetration resistance of fabrics, and the detection sensitivity of the methods and the penetration amount with respect to the relationship between blood and the pathogen have not been studied in detail. Moreover, no standard method using bacteria for evaluation is known. Here, to evaluate penetration resistance of protective clothing materials under applied pressure, the detection sensitivity and the leak amount were investigated by using synthetic blood containing bacteriophage phi-X174 or S. aureus. And the volume of leaked synthetic blood and the amount of test microbe penetration were simultaneously quantified. Our results showed that the penetration detection sensitivity achieved using a test microbial culture was higher than that achieved using synthetic blood at invisible leak level pressures. This finding suggested that there is a potential risk of pathogen penetration even when visual leak of contaminated blood through the protective clothing was not observed. Moreover, at visible leak level pressures, it was found that the amount of test microbe penetration varied at least ten-fold among protective clothing materials classified into the same class of penetration resistance. Analysis of the penetration amount revealed a significant correlation between the volume of penetrated synthetic blood and the amount of test microbe penetration, indicating that the leaked volume of synthetic blood could be considered as a latent indicator for infection risk, that the amount of exposure to contaminated blood corresponds to the risk of infection. Our study helped us ascertain, with high sensitivity, the differences among fabric materials with respect to their protective performance, which may facilitate effective selection of protective clothing depending on the risk assessment.


Assuntos
Substitutos Sanguíneos , Técnicas Microbiológicas , Pressão , Roupa de Proteção/microbiologia , Roupa de Proteção/virologia , Ebolavirus , Humanos , Staphylococcus aureus Resistente à Meticilina , Viabilidade Microbiana , Técnicas Microbiológicas/instrumentação , Técnicas Microbiológicas/métodos , Técnicas Microbiológicas/normas , Sensibilidade e Especificidade
8.
Biocontrol Sci ; 21(2): 81-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27350426

RESUMO

Currently, threats caused by pathogens are serious public health problems worldwide. Protective clothing is essential when one is treating infected patients or dealing with unknown pathogens. Therefore, it is necessary to evaluate the performance of protective clothing against pathogens. In Japan, some methods for evaluating the performance of protective clothing have been established in the Japanese Industrial Standards (JIS). However, a test method against virus aerosols has not been established. Because there is a risk of infection from a live virus during the test, it is necessary to devise a safe method for the virus-aerosol-based test. Here, we propose a new method of safely measuring virus aerosols for the performance evaluation of protective clothing materials. To ensure safety, an inactivated virus was used. As a model virus, the influenza virus was selected owing to the proper small diameter of the virus particles. To quantitatively measure the particle-amount of the inactivated influenza virus, we developed an antigen-capture enzyme-linked immunosorbent assay (ELISA) targeting the M1 protein. Furthermore, we evaluated two materials using our method. Significant differences in the protection performance against the virus aerosol were observed between different sample materials, thereby confirming the applicability of our new method for performance evaluation.


Assuntos
Aerossóis/análise , Ensaio de Imunoadsorção Enzimática , Orthomyxoviridae , Roupa de Proteção/virologia , Antígenos Virais , Difusão Dinâmica da Luz , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Orthomyxoviridae/classificação , Orthomyxoviridae/fisiologia , Orthomyxoviridae/ultraestrutura , Reprodutibilidade dos Testes , Ensaio de Placa Viral
9.
AIDS ; 23(12): 1485-94, 2009 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-19528788

RESUMO

BACKGROUND: Preadministration of high-affinity humanized anti-HIV-1 mAb KD-247 by passive transfer provides sterile protection of monkeys from heterologous chimeric simian/human immunodeficiency virus infection. METHODS: Beginning 1 h, 1 day, or 1 week after simian/human immunodeficiency virus-C2/1 challenge (20 50% tissue culture infective dose), mature, male cynomolgus monkeys received multiple passive transfers of KD-247 (45 mg/kg) on a weekly basis for approximately 2 months. Concentrations and viral loads were measured in peripheral blood, and CD4 T-cell counts were examined in both peripheral blood and various lymphoid tissues. RESULTS: Pharmacokinetic examination revealed similar plasma maintenance levels ranging from 200 to 500 microg/ml of KD-247 in the three groups. One of the six monkeys given KD-247 could not maintain these concentrations, and elicitation of anti-KD-247 idiotype antibody was suggested. All monkeys given KD-247 exhibited striking postinfection protection against both CD4 T-cell loss in various lymphoid tissues and atrophic changes in organs compared with control group animals treated with normal human immunoglobulin G. The KD-247-treated groups were also partially protected against plasma viral load elevation in peripheral blood samples, although the complete protection previously reported with preadministration of this mAb was not achieved. CONCLUSION: Postinfection passive transfer of humanized mAb KD-247 with strong neutralizing capacity against challenged virus simian/human immunodeficiency virus-C2/1 protected CD4 T cells in lymphoid organs.


Assuntos
Linfócitos T CD4-Positivos/imunologia , Proteína gp120 do Envelope de HIV/imunologia , Tecido Linfoide/imunologia , Fragmentos de Peptídeos/imunologia , Vacinas contra a SAIDS/imunologia , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Animais , Anticorpos Monoclonais/sangue , Anticorpos Monoclonais/imunologia , Atrofia/prevenção & controle , Contagem de Linfócito CD4 , Imunização Passiva , Macaca fascicularis , RNA Viral/sangue , Vacinas contra a SAIDS/sangue , Síndrome de Imunodeficiência Adquirida dos Símios/patologia , Síndrome de Imunodeficiência Adquirida dos Símios/virologia , Vírus da Imunodeficiência Símia/isolamento & purificação , Timo/patologia , Carga Viral
10.
J Virol ; 80(11): 5563-70, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16699037

RESUMO

In an accompanying report (Y. Eda, M. Takizawa, T. Murakami, H. Maeda, K. Kimachi, H. Yonemura, S. Koyanagi, K. Shiosaki, H. Higuchi, K. Makizumi, T. Nakashima, K. Osatomi, S. Tokiyoshi, S. Matsushita, N. Yamamoto, and M. Honda, J. Virol. 80:5552-5562, 2006), we discuss our production of a high-affinity humanized monoclonal antibody, KD-247, by sequential immunization with V3 peptides derived from human immunodeficiency virus type 1 (HIV-1) clade B primary isolates. Epitope mapping revealed that KD-247 recognized the Pro-Gly-Arg V3 tip sequence conserved in HIV-1 clade B isolates. In this study, we further demonstrate that in vitro, KD-247 efficiently neutralizes CXCR4- and CCR5-tropic primary HIV-1 clade B and clade B' with matching neutralization sequence motifs but does not neutralize sequence-mismatched clade B and clade E isolates. Monkeys were provided sterile protection against heterologous simian/human immunodeficiency virus challenge by the passive transfer of a single high dose (45 mg per kg of body weight) of KD-247 and afforded partial protection by lower antibody doses (30 and 15 mg per kg). Protective neutralization endpoint titers in plasma at the time of virus challenge were 1:160 in animals passively transferred with a high dose of the antibody. The antiviral efficacy of the antibody was further confirmed by its suppression of the ex vivo generation of primary HIV-1 quasispecies in peripheral blood mononuclear cell cultures from HIV-infected individuals. Therefore, KD-247 promises to be a valuable tool not only as a passive immunization antibody for the prevention of HIV infection but also as an immunotherapy for the suppression of HIV in phenotype-matched HIV-infected individuals.


Assuntos
Anticorpos Monoclonais/imunologia , Anticorpos Anti-HIV/imunologia , Proteína gp120 do Envelope de HIV/imunologia , Infecções por HIV/virologia , Fragmentos de Peptídeos/imunologia , Motivos de Aminoácidos/imunologia , Animais , Reações Cruzadas , Proteína gp120 do Envelope de HIV/química , HIV-1/classificação , HIV-1/imunologia , Haplorrinos , Humanos , Imunização Passiva , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Vírus da Imunodeficiência Símia/imunologia , Especificidade da Espécie
11.
J Virol ; 79(20): 12871-9, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16188989

RESUMO

Virus-specific T-cell responses can limit immunodeficiency virus type 1 (HIV-1) transmission and prevent disease progression and so could serve as the basis for an affordable, safe, and effective vaccine in humans. To assess their potential for a vaccine, we used Mycobacterium bovis bacillus Calmette-Guérin (BCG)-Tokyo and a replication-deficient vaccinia virus strain (DIs) as vectors to express full-length gag from simian immunodeficiency viruses (SIVs) (rBCG-SIVgag and rDIsSIVgag). Cynomolgus macaques were vaccinated with either rBCG-SIVgag dermally as a single modality or in combination with rDIsSIVgag intravenously. When cynomologus macaques were primed with rBCG-SIVgag and then boosted with rDIsSIVgag, high levels of gamma interferon (IFN-gamma) spot-forming cells specific for SIV Gag were induced. This combination regimen elicited effective protective immunity against mucosal challenge with pathogenic simian-human immunodeficiency virus for the 1 year the macaques were under observation. Antigen-specific intracellular IFN-gamma activity was similarly induced in each of the macaques with the priming-boosting regimen. Other groups receiving the opposite combination or the single-modality vaccines were not effectively protected. These results suggest that a recombinant M. bovis BCG-based vector may have potential as an HIV/AIDS vaccine when administered in combination with a replication-deficient vaccinia virus DIs vector in a priming-boosting strategy.


Assuntos
Vacina BCG/administração & dosagem , Vetores Genéticos , Esquemas de Imunização , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Vacina Antivariólica/administração & dosagem , Vacinação , Animais , Vacina BCG/genética , Células Cultivadas , Produtos do Gene gag/genética , Produtos do Gene gag/imunologia , Imunização Secundária , Interferon gama/imunologia , Leucócitos Mononucleares/imunologia , Macaca fascicularis , Masculino , Vacinas contra a SAIDS/administração & dosagem , Vacinas contra a SAIDS/imunologia , Síndrome de Imunodeficiência Adquirida dos Símios/prevenção & controle , Vírus da Imunodeficiência Símia/imunologia , Vacina Antivariólica/genética , Especificidade da Espécie , Vacinas Sintéticas/administração & dosagem
12.
Virology ; 313(1): 8-12, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-12951016

RESUMO

We have monitored kinetics of peripheral blood Interleukin (IL)-18 level, viral RNA load, and CD4(+) T cell counts in cynomolgus and rhesus macaques following infections of various simian/human immunodeficiency viruses (SHIVs) causing differential pathogenicity. Infections of cynomolgus and rhesus macaques with pathogenic SHIVs-C2/1 and -89.6PD, respectively, induced high levels of plasma IL-18 (0.1-1 ng/ml) and enhanced apoptosis of peripheral blood T cells during primary viremia, along with a rapid decline of CD4(+) T cells and a high level of set point viral load after primary viremia (six of six cases). In contrast, infections of cynomolgus macaques with nonpathogenic SHIVs-TH09V3 and -MD14 did not cause such IL-18 elevation, showing no decline of CD4(+) T cells and no or low viral set point level following primary viremia (three of three cases). Thus, the elevation of circulating IL-18 level during primary viral infection can be a good indicator of an active pathogenic viral infection. However, the role of increased IL-18 remains to be elucidated and needs further investigation.


Assuntos
Interleucina-18/sangue , Síndrome de Imunodeficiência Adquirida dos Símios/imunologia , Vírus da Imunodeficiência Símia , Animais , Apoptose , Biomarcadores/sangue , Contagem de Linfócito CD4 , Modelos Animais de Doenças , HIV/patogenicidade , Macaca fascicularis , Macaca mulatta , Síndrome de Imunodeficiência Adquirida dos Símios/sangue , Síndrome de Imunodeficiência Adquirida dos Símios/diagnóstico , Vírus da Imunodeficiência Símia/patogenicidade , Linfócitos T/fisiologia , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...