Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 26(8): 2790-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26601972

RESUMO

OBJECTIVES: To investigate the superiority of radial volumetric breath-hold examination (r-VIBE) with k-space weighted image contrast reconstruction (KWIC) over Cartesian VIBE (c-VIBE) for reducing motion artefacts. METHODS: We acquired r-VIBE-KWIC and c-VIBE images in 10 healthy volunteers. Each acquisition lasted 24 seconds. The volunteers held their breath for decreasing lengths of time during the acquisitions, from 24 to 0 seconds (protocols A-E). Magnetic resonance images at the level of the right portal vein and confluence of hepatic veins were assessed by two readers using a five-point scale with a higher number indicating a better study. RESULTS: The mean scores for the complete r-VIBE-KWIC series (r-VIBEfull) and first r-VIBE-KWIC series (r-VIBE1) were not significantly lower than those for c-VIBE in any protocols. The mean scores for c-VIBE were lower than those for r-VIBEfull and r-VIBE1 in protocols C and D. The mean score for c-VIBE was lower than that for r-VIBEfull in protocol E. The mean score for the eighth r-VIBE-KWIC series (r-VIBE8) was lower than that for c-VIBE only in protocol B. CONCLUSION: r-VIBE-KWIC minimised artefacts relative to c-VIBE at any slice location. The r-VIBE-KWIC's sub-frame images during the breath-holding period were hardly affected by another failed breath-holding period. KEY POINTS: • A two-reader study revealed r-VIBE-KWIC's advantages over c-VIBE • The image quality of r-VIBE-KWIC's sub-frame images was maintained during breath holding • Full-frame r-VIBE-KWIC images minimized motion artefacts caused by breathing • A complete breath holding over half the acquisition time is recommended for c-VIBE • c-VIBE was susceptible to respiratory motion especially in the subphrenic region.


Assuntos
Artefatos , Veias Hepáticas/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Veia Porta/diagnóstico por imagem , Adulto , Suspensão da Respiração , Meios de Contraste/farmacologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade
2.
Eur J Radiol ; 83(10): 1728-33, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25043495

RESUMO

PURPOSE: We aimed to clarify the usefulness of free-breathing readout-segmented echo-planar imaging (RESOLVE), which is multi-shot echo-planar imaging based on a 2D-navigator-based reacquisition technique, for detecting malignant liver tumor. MATERIALS AND METHODS: In 77 patients with malignant liver tumors, free-breathing RESOLVE and respiratory-triggered single-shot echo-planar imaging (SS-EPI) at 3-T MR unit were performed. We set a scan time up to approximately 5 min (300s) before examination, measured actual scan time and assessed (1) susceptibility and (2) motion artifacts in the right and left liver lobes (3, no artifact; 1, marked), and (3) detectability of malignant liver tumors (3, good; 1, poor) using a 3-point scale. RESULTS: The median actual scan time of RESOLVE/SS-EPI was 365/423s. The median scores of each factor in RESOLVE/SS-EPI were as following in this order: (1) 3/2 (right lobe); 3/3 (left lobe), (2) 2/3 (right lobe); 1/2 (left lobe), and (3) 3/3, respectively. Significant differences were noted between RESOLVE and SS-EPI in all evaluated factors (P<0.05) except for susceptibility of left lobe and detectability of the lesions. CONCLUSION: Despite the effect of motion artifacts, RESOLVE provides a comparable detectability of the lesion and the advantage of reducing scanning time compared with SS-EPI.


Assuntos
Imagem Ecoplanar/métodos , Neoplasias Hepáticas/diagnóstico , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Biópsia , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Respiração
3.
Eur Radiol ; 24(6): 1290-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24633374

RESUMO

OBJECTIVES: To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. METHODS: We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. RESULTS: Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. CONCLUSIONS: Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. KEY POINTS: Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.


Assuntos
Gadolínio DTPA , Hepatopatias/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/patologia , Artefatos , Suspensão da Respiração , Meios de Contraste , Bases de Dados Factuais , Feminino , Artéria Hepática/patologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Fígado/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...