1.
Data Brief ; 38: 107386, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34604479

RESUMO

This data article presents the raw data used in the article "Experimental and analytical evaluation of exhaust air heat pumps in ventilation-based heating systems" [1]. The data set contains measurement results of a field monitoring on a residential exhaust air heat pump system (air-to-air heat pump) in Germany. This data could be used to investigate the dynamic behavior and performance of the exhaust air heat pump systems. The data set contains air temperature and humidity of all four sides of the heat pump unit. Moreover, the electrical consumption of the unit and the dynamic pressure difference on the exhaust side (as indication of the air volume rate) could be also found in the data set.