1.
Sci Rep ; 12(1): 9577, 2022 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-35688890

RESUMO

We present a compact multi-modal and multi-scale retinal imaging instrument with an angiographic functional extension for clinical use. The system integrates scanning laser ophthalmoscopy (SLO), optical coherence tomography (OCT) and OCT angiography (OCTA) imaging modalities and provides multi-scale fields of view. For high resolution, and high lateral resolution in particular, cellular imaging correction of aberrations by adaptive optics (AO) is employed. The entire instrument has a compact design and the scanning head is mounted on motorized translation stages that enable 3D self-alignment with respect to the subject's eye by tracking the pupil position. Retinal tracking, based on the information provided by SLO, is incorporated in the instrument to compensate for retinal motion during OCT imaging. The imaging capabilities of the multi-modal and multi-scale instrument were tested by imaging healthy volunteers and patients.


Assuntos
Pupila , Retina , Humanos , Oftalmoscopia/métodos , Óptica e Fotônica , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
2.
Biomed Opt Express ; 12(10): 5969-5990, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745716

RESUMO

The pyramid wavefront sensor (P-WFS) has replaced the Shack-Hartmann (SH-) WFS as the sensor of choice for high-performance adaptive optics (AO) systems in astronomy. Many advantages of the P-WFS, such as its adjustable pupil sampling and superior sensitivity, are potentially of great benefit for AO-supported imaging in ophthalmology as well. However, so far no high quality ophthalmic AO imaging was achieved using this novel sensor. Usually, a P-WFS requires modulation and high precision optics that lead to high complexity and costs of the sensor. These factors limit the competitiveness of the P-WFS with respect to other WFS devices for AO correction in visual science. Here, we present a cost-effective realization of AO correction with a non-modulated P-WFS based on standard components and apply this technique to human retinal in vivo imaging using optical coherence tomography (OCT). P-WFS based high quality AO imaging was successfully performed in 5 healthy subjects and smallest retinal cells such as central foveal cone photoreceptors are visualized. The robustness and versatility of the sensor is demonstrated in the model eye under various conditions and in vivo by high-resolution imaging of other structures in the retina using standard and extended fields of view. As a quality benchmark, the performance of conventional SH-WFS based AO was used and successfully met. This work may trigger a paradigm shift with respect to the wavefront sensor of choice for AO in ophthalmic imaging.

3.
Biomed Opt Express ; 11(8): 4520-4535, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32923061

RESUMO

Using adaptive optics optical coherence tomography, human photoreceptors and retinal pigment epithelium (RPE) cells are typically visualized on a small field of view of ∼1° to 2°. In addition, volume averaging is required for visualizing the RPE cell mosaic. To increase the imaging area, we introduce a lens based spectral domain AO-OCT system that shows low aberrations within an extended imaging area of 4°×4° while maintaining a high (theoretical) transverse resolution (at >7 mm pupil diameter) in the order of 2 µm. A new concept for wavefront sensing is introduced that uses light mainly originating from the RPE layer and yields images of the RPE cell mosaic in a single volume acquisition. The capability of the instrument for in vivo imaging is demonstrated by visualizing various cell structures within the posterior retinal layers over an extended field of view.

4.
Sci Rep ; 8(1): 15816, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30361556

RESUMO

The tremendous advances achieved in the biophotonics technologies have intensified the necessity for non-invasive modalities that can characterize diverse biological materials with increased sensitivity and resolution. Optical coherence tomography (OCT) is one of the techniques that has been applied for biological applications in medicine and agriculture to identify structural properties. Herein, we report the successful incorporation of OCT for the identification of morphological changes that occur as a result of the bitter rot disease, through continuous detection of structural changes. Detailed inner morphological structural changes occurring in fruit specimens were precisely analyzed as a function of the disease incubation period using OCT. The conducted histological correlation and quantitative three-dimensional evaluations provide a robust platform for further discoveries related to plant materials. The results highlight the initial identification of bitter rot progression on apple specimens owing to the non-invasive inspection capability of OCT. Therefore, we expect that the proposed method will enable immediate sensitivity improvements in the inspection of plant diseases for postharvest utility.


Assuntos
Malus/microbiologia , Fótons , Doenças das Plantas/microbiologia , Tomografia de Coerência Óptica/métodos , Progressão da Doença , Imageamento Tridimensional , Malus/anatomia & histologia , Estatística como Assunto
5.
Sensors (Basel) ; 18(8)2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30071634

RESUMO

The non-destructive classification of plant materials using optical inspection techniques has been gaining much recent attention in the field of agriculture research. Among them, a near-infrared (NIR) imaging method called optical coherence tomography (OCT) has become a well-known agricultural inspection tool since the last decade. Here we investigated the non-destructive identification capability of OCT to classify diversely stained (with various staining agents) Capsicum annuum seed specimens of different cultivars. A swept source (SS-OCT) system with a spectral band of 1310 nm was used to image unstained control C. annuum seeds along with diversely stained Capsicum seeds, belonging to different cultivar varieties, such as C. annuum cv. PR Ppareum, C. annuum cv. PR Yeol, and C. annuum cv. Asia Jeombo. The obtained cross-sectional images were further analyzed for the changes in the intensity of back-scattered light (resulting due to dye pigment material and internal morphological variations) using a depth scan profiling technique to identify the difference among each seed category. The graphically acquired depth scan profiling results revealed that the control specimens exhibit less back-scattered light intensity in depth scan profiles when compared to the stained seed specimens. Furthermore, a significant back-scattered light intensity difference among each different cultivar group can be identified as well. Thus, the potential capability of OCT based depth scan profiling technique for non-destructive classification of diversely stained C. annum seed specimens of different cultivars can be sufficiently confirmed through the proposed scheme. Hence, when compared to conventional seed sorting techniques, OCT can offer multipurpose advantages by performing sorting of seeds in respective to the dye staining and provides internal structural images non-destructively.

6.
Sensors (Basel) ; 17(12)2017 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-29231871

RESUMO

We demonstrate that optical coherence tomography (OCT) is a plausible optical tool for in vivo detection of plant seeds and its morphological changes during growth. To investigate the direct impact of salt stress on seed germination, the experiment was conducted using Capsicum annuum seeds that were treated with different molar concentrations of NaCl. To determine the optimal concentration for the seed growth, the seeds were monitored for nine consecutive days. In vivo two-dimensional OCT images of the treated seeds were obtained and compared with the images of seeds that were grown using sterile distilled water. The obtained results confirm the feasibility of using OCT for the proposed application. Normalized depth profile analysis was utilized to support the conclusions.


Assuntos
Capsicum , Germinação , Sementes , Cloreto de Sódio , Água
7.
Sensors (Basel) ; 17(5)2017 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-28524105

RESUMO

The structural analysis of nylon/graphene oxide (NY/GO) and polyetherblockamide/ trisilinolphenyl-polyhederal oligomeric silsesquioxane (PEBA/t-POSS) composites were performed using high-resolution spectral domain optical coherence tomography (SD-OCT). This optical technology revealed both cross-sectional, as well as sub-layer depth information of sample. The non-destructive real-time imaging demonstrated the nature of defects in the composites. The thickness and location of each defect point in the composites were measured using A-scan analysis on the SD-OCT images. The cross-sectional and volumetric images clearly demonstrate the effectiveness of SD-OCT for composite research, as well as the for industrial quality assurance of polymer materials.

8.
Sensors (Basel) ; 16(11)2016 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-27869659

RESUMO

We report a wavelength swept laser-based full-field optical coherence tomography for measuring the surfaces and thicknesses of refractive and reflective samples. The system consists of a galvo filter-based wavelength swept laser and a simple Michelson interferometer. Combinations of the reflective and refractive samples are used to demonstrate the performance of the system. By synchronizing the camera with the source, the cross-sectional information of the samples can be seen after each sweep of the swept source. This system can be effective for the thickness measurement of optical thin films as well as for the depth investigation of samples in industrial applications. A resolution target with a glass cover slip and a step height standard target are imaged, showing the cross-sectional and topographical information of the samples.

9.
Sensors (Basel) ; 16(10)2016 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-27690043

RESUMO

An application of spectral domain optical coherence tomography (SD-OCT) was demonstrated for a fast industrial inspection of an optical thin film panel. An optical thin film sample similar to a liquid crystal display (LCD) panel was examined. Two identical SD-OCT systems were utilized for parallel scanning of a complete sample in half time. Dual OCT inspection heads were utilized for transverse (fast) scanning, while a stable linear motorized translational stage was used for lateral (slow) scanning. The cross-sectional and volumetric images of an optical thin film sample were acquired to detect the defects in glass and other layers that are difficult to observe using visual inspection methods. The rapid inspection enabled by this setup led to the early detection of product defects on the manufacturing line, resulting in a significant improvement in the quality assurance of industrial products.

10.
J Biomed Opt ; 21(7): 76005, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27401937

RESUMO

A method for depth enhancement is presented using a bidirectional imaging modality for spectral domain optical coherence tomography (SD-OCT). Two precisely aligned sample arms along with two reference arms were utilized in the optical configuration to scan the samples. Using exemplary images of the optical resolution target, Scotch tape, a silicon sheet with two needles, and a leaf, we demonstrated how the developed bidirectional SD-OCT imaging method increases the ability to characterize depth-enhanced images. The results of the developed system were validated by comparing the images with the standard OCT configuration (single-sample arm setup). Given the advantages of higher resolution and the ability to visualize deep morphological structures, this method can be utilized to increase the depth dependent fall-off in samples with limited thickness. Thus, the proposed bidirectional imaging modality is apt for cross-sectional imaging of entire samples, which has the potential capability to improve the diagnostic ability.


Assuntos
Tomografia de Coerência Óptica/métodos , Refratometria , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentação
11.
Biomed Mater Eng ; 26 Suppl 1: S1465-71, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26405909

RESUMO

Adaptive optics plays an important role in the correction of high-order aberrations to enhance lateral resolution. An OCT system coupled with a programmable phase modulator is designed to verify lateral resolution improvement. The Hamamatsu high-resolution, non-pixelized, optically addressed light modulator (PAL-SLM) PPM X7550 series is used to correct aberrations, utilizing a simple method based on phase information from OCT images. The advantages of this method are its high simplicity and low cost. A raster scanning technique is adopted to scan samples covered with scattering suspension. Metal lines covered with scattering suspension are imaged, and a respective correction is applied to remove the aberration. Results demonstrate an improvement in lateral resolution on metal grid samples.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Dispositivos Ópticos , Processamento de Sinais Assistido por Computador/instrumentação , Tomografia de Coerência Óptica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...