2.
Artigo em Russo | MEDLINE | ID: mdl-1326193

RESUMO

A method for stereotaxic intratissue radiotherapy of brain tumors based on the findings of computed tomography is described. Radiosurgical implantation of sources with increased 252Cf content emitting mixed neutron + gamma-radiation was accomplished by means of an ANET-B apparatus by the afterloading method. Neutron irradiation is particularly effective in patients with malignant tumors possessing a large fraction of cells in a state of deep anoxia. Dosimetric planning was conducted by means of an original computer system. Devices and radiation-technical equipment for adaptation of the ANET-B apparatus for irradiation of neurosurgical patients are described. The indications for the use of this method and its place among the complex of measures for the treatment of patients with new growths of the brain are discussed. The first experience in using CT-stereotaxic neutron brachytherapy with californium sources on the ANET-B apparatus for the treatment of 6 patients with malignant glial tumors of the brain is dwelt on.


Assuntos
Braquiterapia/métodos , Neoplasias Encefálicas/radioterapia , Califórnio/uso terapêutico , Nêutrons/uso terapêutico , Técnicas Estereotáxicas , Tomografia Computadorizada por Raios X , Adulto , Braquiterapia/instrumentação , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Humanos , Masculino , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
Med Radiol (Mosk) ; 36(4): 44-8, 1991.
Artigo em Russo | MEDLINE | ID: mdl-2034088

RESUMO

A computerized system PLUT-B intended for a dosimetric design of stereotaxic neutron brachytherapy of brain tumors, was developed. It is capable of simulating dose distribution in various parameters of irradiation, manipulating them, retaining the surgical aspects within the field of vision, and arriving at an acceptable dosimetric plan. The system permits visualization of a target with an applied dose field in the multiwindow mode, layer-by-layer vision in any direction, displaying a scheme of implantation, and drawing up of maps of isodose distributions. It is intended to be used by a physician, convenient in operation, the time at the design stage is 35-40 minutes.


Assuntos
Braquiterapia , Neoplasias Encefálicas/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Neoplasias Encefálicas/cirurgia , Humanos , Postura , Técnicas Estereotáxicas