Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 199: 177-183, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30529566

RESUMO

PURPOSE: To evaluate the role of a novel automated detection software as compared to human operators in assessing the presence and depth of stromal demarcation line on optical coherence tomography (OCT) in keratoconus eyes post cross-linking. DESIGN: Reliability analysis study. METHODS: Two independent operators and an automated detection software examined corneal OCTs of 25 eyes of 25 patients post corneal cross-linking using the Dresden protocol, at 3 months postoperatively. Operators evaluated the presence of the demarcation line and measured its depth by looking at OCT images (128 cuts) on 2 separate occasions 1 week apart. The automated software examined all 128 cuts of each OCT measurement. RESULTS: The mean corneal demarcation line depth was 321.54 ± 47.71, 322.86 ± 45.77, and 309.21 ± 40.98 µm, as computed by the automated detection software and the human operators, respectively. The intraclass correlation coefficients (ICC) between the automated detection software and Observers #1 and #2 were 0.884 and 0.847, respectively (P < .001). The ICC for interoperator reproducibility was 0.890, and for intraoperator repeatability for Operator #1 and Observer #2 were 0.922 and 0.925, respectively. The ICC for intersoftware repeatability was 1. Bland-Altman plots showed a good agreement between both observers and the software, with adequate 95% limits of agreement. CONCLUSION: Detection of the demarcation line by human operators is repeatable and reproducible, but it can be further optimized and standardized by an ultrafast and accurate automated software detection tool, providing a reliable indicator for treatment success.


Assuntos
Substância Própria/diagnóstico por imagem , Reagentes de Ligações Cruzadas , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Tomografia de Coerência Óptica/métodos , Adulto , Colágeno/metabolismo , Substância Própria/metabolismo , Topografia da Córnea , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Ceratocone/metabolismo , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Riboflavina/uso terapêutico , Raios Ultravioleta , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...