Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Phys Rev Lett ; 101(22): 221101, 2008 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-19113471

RESUMO

The 7 year data set of the Milagro TeV observatory contains 2.2 x 10(11) events of which most are due to hadronic cosmic rays. These data are searched for evidence of intermediate scale structure. Excess emission on angular scales of approximately 10 degrees has been found in two localized regions of unknown origin with greater than 12sigma significance. Both regions are inconsistent with pure gamma-ray emission with high confidence. One of the regions has a different energy spectrum than the isotropic cosmic-ray flux at a level of 4.6sigma, and it is consistent with hard spectrum protons with an exponential cutoff, with the most significant excess at approximately 10 TeV. Potential causes of these excesses are explored, but no compelling explanations are found.

2.
Phys Rev Lett ; 95(25): 251103, 2005 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-16384445

RESUMO

Gamma-ray emission from a narrow band at the galactic equator has previously been detected up to 30 GeV. We report evidence for a TeV gamma-ray signal from a region of the galactic plane by Milagro, a large-field-of-view water Cherenkov detector for extensive air showers. An excess with a significance of 4.5 standard deviations has been observed from the region of galactic longitude l E (40 degrees, 100 degrees) and latitude /b/ < 5 degrees. Under the assumption of a simple power law spectrum, with no cutoff in the EGRET-Milagro energy range, the measured integral flux is phi gamma(>3.5 TeV) = (6.4 +/- 1.4 +/- 2.1) x 10(-11) cm(-2) s(-1) sr(-1). This flux is consistent with an extrapolation of the EGRET spectrum between 1 and 30 GeV in this galactic region.

3.
Otolaryngol Head Neck Surg ; 125(4): 346-50, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11593169

RESUMO

INTRODUCTION: In an earlier study, we demonstrated the feasibility of using electrocochleography (ECoG) to document changes in inner ear function objectively after intranasal challenge of patients with inhalant allergy (with no prior immunotherapy) and Meniere's disease, using the antigen to which they were most sensitive. OBJECTIVE: We expand on this earlier study and continue to investigate the feasibility of this model in a subset of patients with inhalant allergy and Meniere's disease after immunotherapy. STUDY DESIGN: Prospective study of 11 patients identified with both Meniere's disease and inhalant allergy in the practices of 2 neurotologists at our institution. Patients underwent a baseline ECoG, followed by intranasal challenge with the allergen to which they were most sensitive. This was followed by a second ECoG. RESULTS: Six of 11 patients had at least 1 year of immunotherapy (group 1), and 5 of 11 had had 0 to 6 months of immunotherapy (group 2). Four of 6 group 1 patients had a >15% increase in SP/AP ratio after immunotherapy. In group 2, 2 patients increased the SP/AP in at least 1 ear. No patient with a normal ECoG experienced vestibular symptoms after allergen challenge, whereas 2 of group 1 and 2 of group 2 had vestibular symptoms with abnormal ECoGs. CONCLUSION: This protocol is a useful tool for investigating the relationship of inhalant allergy and Meniere's disease, but needs a larger group of patients and further study to draw valid statistical conclusions.


Assuntos
Alérgenos , Audiometria de Resposta Evocada , Doença de Meniere/imunologia , Doença de Meniere/fisiopatologia , Hipersensibilidade Respiratória/imunologia , Hipersensibilidade Respiratória/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Doença de Meniere/complicações , Pessoa de Meia-Idade , Estudos Prospectivos , Hipersensibilidade Respiratória/complicações , Sensibilidade e Especificidade
4.
Laryngoscope ; 111(10): 1682-6, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11801925

RESUMO

INTRODUCTION: Partially implantable hearing devices have been developed to address some of the user-perceived shortcomings of standard amplification systems. Partially implantable devices are purported to provide improved sound quality as a result of decreased occlusion, decreased feedback, and enhanced clarity resulting from increased high-frequency gain. Such improvements may result in greater user satisfaction. To justify selection of a partially implantable device and undergoing a minor surgical procedure, verification techniques must be used to document user improvement or increased satisfaction over conventional amplification. OBJECTIVE: To evaluate patient satisfaction with the SOUNDTEC direct hearing system. STUDY DESIGN: Within-subjects repeated measures design. METHODS: Objective and subjective evaluation pre- and post-implantation with the SOUNDTEC device. Verification techniques included tonal functional gain measures with traditional amplification and the SOUNDTEC device, word recognition in quiet (NU-6) and in noise (SPIN), the Abbreviated Profile of Hearing Aid Benefit (APHAB), and the Hough Ear Institute Profile (HEIP). RESULTS: Although there was no significant difference between optimal traditional amplification and the SOUNDTEC device for speech perception measures, the SOUNDTEC device yielded statistically significant increased high-frequency functional gain. Subjective reports indicated that the SOUNDTEC device provides a cleaner, more natural sound without feedback than traditional amplification. CONCLUSIONS: Partially implantable hearing aids may address some of the limitations of traditional amplification systems.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial/reabilitação , Implantação de Prótese/instrumentação , Adulto , Idoso , Audiometria de Tons Puros , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Desenho de Prótese , Testes de Discriminação da Fala
5.
Astrophys J ; 533(2): L119-L122, 2000 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-10770704

RESUMO

Milagrito, a detector sensitive to very high energy gamma rays, monitored the northern sky from 1997 February through 1998 May. With a large field of view and a high duty cycle, this instrument was well suited to perform a search for TeV gamma-ray bursts (GRBs). We report on a search made for TeV counterparts to GRBs observed by BATSE. BATSE detected 54 GRBs within the field of view of Milagrito during this period. An excess of events coincident in time and space with one of these bursts, GRB 970417a, was observed by Milagrito. The excess has a chance probability of 2.8x10-5 of being a fluctuation of the background. The probability for observing an excess at least this large from any of the 54 bursts is 1.5x10-3. No significant correlations were detected from the other bursts.

6.
Otolaryngol Head Neck Surg ; 122(3): 319-29, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10699803

RESUMO

METHODS: Vestibular complaints of Gulf War veterans were characterized by a nested case-control study of 23 veterans with 3 different Gulf War syndromes and 20 matched control subjects. All subjects completed a standardized symptom questionnaire and underwent standard audiovestibular tests administered by audiologists blinded to group identities. RESULTS: The prevalence of reported dizzy spells was higher in veterans with Gulf War syndromes 1 (100%), 2 (85%), and 3 (100%) than in controls (25%, P < 0.0001). Dizzy spells were more frequent, lasted longer, and involved a wider variety of accompanying symptoms in veterans with syndrome 2 than in those with syndromes 1 and 3. Audiovestibular testing showed greater interocular asymmetry of nystagmic velocity on sinusoidal harmonic acceleration in syndromes 1 (P = 0.015) and 2 (P = 0.002), greater asymmetry of saccadic velocity in syndrome 2 (P = 0.4), diminished nystagmic velocity after caloric stimulation bilaterally in syndrome 3 (P = 0.02 to 0.04), more subjects with pathologic nystagmus (P = 0. 09), and greater interside asymmetry of wave I to III interpeak latency on auditory brain stem response in syndromes 1 (P = 0.005) and 2 (P = 0.07). Asymmetry of gain on sinusoidal harmonic acceleration and pathologic nystagmus were most strongly associated with symptoms of paroxysmal vertigo (P = 0.002 and 0.07, respectively); asymmetry of saccadic velocity, with the severity of vertigo (P = 0.004); and abnormal caloric response, with chronic dysequilibrium (P = 0.006). CONCLUSIONS: The findings are compatible with a subtle neurologic injury from organophosphate-induced delayed neurotoxicity.


Assuntos
Síndrome do Golfo Pérsico/diagnóstico , Doenças Vestibulares/diagnóstico , Adulto , Audiometria de Resposta Evocada , Tronco Encefálico/fisiopatologia , Estudos de Casos e Controles , Estudos Transversais , Dominância Cerebral/fisiologia , Eletronistagmografia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Humanos , Incidência , Masculino , Doença de Meniere/diagnóstico , Doença de Meniere/epidemiologia , Doença de Meniere/fisiopatologia , Pessoa de Meia-Idade , Síndrome do Golfo Pérsico/epidemiologia , Síndrome do Golfo Pérsico/fisiopatologia , Doenças Vestibulares/epidemiologia , Doenças Vestibulares/fisiopatologia , Testes de Função Vestibular , Vestíbulo do Labirinto/fisiopatologia
7.
AORN J ; 71(3): 645-8, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10736648

RESUMO

Perioperative nurses who pursue nontraditional roles with medical products companies must assess their personal and professional skills to determine if they would fill that role satisfactorily. They must consider the risks involved and determine if the job is appealing. Working as a health care industry nurse can positively affect patient outcomes while providing a company with unique skills and insights. This career choice can be very rewarding.


Assuntos
Escolha da Profissão , Setor de Assistência à Saúde , Descrição de Cargo , Enfermagem Perioperatória , Humanos , Descrição de Cargo/normas , Enfermagem Perioperatória/organização & administração , Competência Profissional/normas , Estados Unidos
8.
Astrophys J ; 525(1): L25-L28, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10511505

RESUMO

The Milagrito water Cerenkov detector near Los Alamos, New Mexico, was operated as a sky monitor at energies of a few TeV between 1997 February and 1998 May, including the period of the strong, long-lasting 1997 flare of Markarian 501. Milagrito served as a test run for the full Milagro detector. An event excess with a significance of 3.7 sigma from Markarian 501 was observed, in agreement with expectations.

9.
Otolaryngol Head Neck Surg ; 121(3): 283-4, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10471872

RESUMO

Numerous observers have suggested a relationship between allergy and Meniere's disease, but objective proof has heretofore been limited. Using standard criteria, we studied a group of 7 patients with previously diagnosed Meniere's disease in whom significant allergy to 1 or more inhalants had also been diagnosed. Patients underwent a baseline electrocochleographic study followed by intranasal challenge with a carefully quantified amount of the allergen to which they were most sensitive. This was followed by a second electrocochleogram. Four of the 7 patients demonstrated at least a 15% increase in the summating potential/action potential ratio in 1 ear, associated with the production of subjective inner ear symptoms. We present this protocol as a potentially useful tool to further study whether inhalant allergy may be a causative factor in patients with Meniere's disease.


Assuntos
Alérgenos/administração & dosagem , Audiometria de Resposta Evocada , Doença de Meniere/diagnóstico , Hipersensibilidade Respiratória/diagnóstico , Administração Intranasal , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Doença de Meniere/etiologia , Doença de Meniere/imunologia , Pessoa de Meia-Idade , Teste de Radioalergoadsorção , Hipersensibilidade Respiratória/complicações , Hipersensibilidade Respiratória/imunologia
10.
Am J Otol ; 20(3): 325-30, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10337972

RESUMO

OBJECTIVE: To introduce a new protocol for diagnostic electrocochleography using a pretest oral salt load to improve test sensitivity in patients with suspected inner ear fluid imbalance. STUDY DESIGN: A retrospective review of patients who reported vertigo that, by medical history, was suggestive of an inner ear fluid imbalance was preformed. The patients received a complete audiovestibular evaluation that included a baseline electrocochleogram. Despite the incapacitating nature of their vertigo, there were no symptoms or electrophysiologic abnormalities that would isolate an etiologic ear. After the baseline studies, the patients received 4 g of sodium chloride daily for 3 days before repeat electrocochleography. A control group of 13 healthy volunteers with normal baseline electrocochleography and pure tone audiometry was tested under similar conditions. SETTING: This study was conducted at an ambulatory care clinic associated with a tertiary referral medical center. INTERVENTION: Electrocochleography was performed using alternating polarity clicks presented at a rate of 9.7/sec at 95 dB nHL by an extratympanic TIPtrode electrode and recorded with a Nicolet Spirit (Nicolet Instrument Corp., Madison, WI, U.S.A.). Responses were averaged for 1000 sweeps using a 10-msec time base with bandpass filtering from 5 to 1500 Hz. A summating potential/action potential (SP/AP) ratio of 0.37 was considered the upper limit of normal. MAIN OUTCOME MEASURES: Enhancement in the SP/AP ratio from a normal baseline value to > 0.37 after oral salt loading was indicative of a positive test. RESULTS: None of the ears from control subjects had a positive salt load electrocochleogram, and one or both ears in 38% of the patients in the study group with normal baseline SP/AP ratios and symptoms of inner ear fluid imbalance converted to abnormal. The mean SP/AP ratio of the control group for the conditions before and after salt-load was not statistically different (p = 0.48), although the difference in the mean SP/AP ratio in the study group after salt loading was statistically significant (p = 1.329 x 10(-5)). CONCLUSIONS: A group of patients who reported vertigo with no localizing abnormalities had a statistically significant increase in the mean SP/AP ratio after ingestion of a large quantity of sodium chloride. A modest percentage had elevation of the SP/AP ratio above the upper limit of normal for our audiovestibular lab. The localization of a "salt-senstitive" ear could assist the clinician in the management of these difficult problems with long-term medical therapy or surgical treatment when alternative measures fail.


Assuntos
Audiometria de Resposta Evocada/métodos , Líquidos Labirínticos/metabolismo , Doença de Meniere/diagnóstico , Cloreto de Sódio/farmacocinética , Adolescente , Adulto , Idoso , Feminino , Humanos , Doença de Meniere/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Nervo Vestibular/cirurgia
11.
Semin Perioper Nurs ; 7(4): 222-5, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9866626

RESUMO

Type I allergy to latex did not appear in the literature until 1979. For over 100 years people have used natural rubber latex products without apparent problems. Why are allergies appearing now? Scientists are not absolutely sure. Reasons may include an unprecedented increase in the use of latex gloves, changes in the manufacturing process by some manufacturers, and the switch to one-time-use disposable gloves. To reduce the risk of latex protein allergy, health care workers should use nonlatex gloves for activities that are not likely to involve contact with infectious materials. Appropriate barrier protection is necessary when handling infectious materials. When using latex gloves, use powder-free gloves with reduced protein content. Sensitized individuals should use only nonlatex gloves.


Assuntos
Luvas Protetoras/efeitos adversos , Ocupações em Saúde , Hipersensibilidade ao Látex/epidemiologia , Doenças Profissionais/epidemiologia , Humanos , Incidência , Hipersensibilidade ao Látex/etiologia , Hipersensibilidade ao Látex/prevenção & controle , Doenças Profissionais/etiologia , Doenças Profissionais/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...