Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Zhongguo Zhong Yao Za Zhi ; 45(22): 5511-5517, 2020 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-33350213

RESUMO

Evaporative light scattering detector(ELSD) and charged aerosol detector(CAD) methods were established in this study for the content determination of four kinds of sugars in Zhusheyong Yiqi Fumai(YQFM), and the factors affecting the accuracy of CAD methods were discussed. HPLC-ELSD chromatographic separation was performed on a Shodex Asahipak NH2 P-50 column with acetonitrile-water(75∶25)as the mobile phase, with a flow rate of 0.8 mL·min~(-1), drift tube temperature of 80 ℃. The analysis by HPLC-CAD was performed on the same column with acetonitrile-water as mobile phase for gradient elution, with a flow rate of 0.8 mL·min~(-1), a neb temperature of 45 ℃, and power function(PF) of 1.3. The samples of YQFM were detected by ELSD and CAD respectively. It was found that YQFM was composed of fructose, glucose, sucrose and maltose. The linear relationship of the two methods was good, and the recoveries, reproducibility and stability of these four kinds of sugars measured by the two methods satisfied the requirements of methodology. Both CAD and ELSD detectors were accurate and reliable in detecting saccharides components in YQFM. In addition, it was revealed in this study for the first time that the PF parameter of CAD had an important influence on the accuracy of sugar determination and acted as the key parameter of CAD method. It was also found that for CAD, a non-linear detector, there was no significant difference between the results of linear regression and logarithmic regression.


Assuntos
Carboidratos , Açúcares , Aerossóis , Cromatografia Líquida de Alta Pressão , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação
2.
Rev Sci Instrum ; 91(1): 015113, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012637

RESUMO

A tensile machine is designed for in situ scattering investigation of elastomers in the cyclic tensile process. The specimen is stretched by two linearly moving clamps in the opposite direction; thus, the center of the specimen is kept stationary during the tensile test. With this configuration, either X-ray scattering or neutron scattering can be carried out easily. A high speed direct current motor is used to drive the machine, providing a wide tensile speed range from 1.28 × 10-3 mm/s to 102.4 mm/s. Cyclic tension is achieved by program controlled motor rotation, and the engineering stress-strain curve can be saved automatically in each cycle. Moreover, an independent displacement sensor is used to check the possible accumulative error of position during cyclic tension. The orientation change of multiwall carbon nanotube filled silicon rubber is investigated by small angle neutron scattering to test the machine, which shows that the machine is capable of combining the cyclic tensile test with in situ scattering measurement.

3.
BMC Womens Health ; 20(1): 1, 2020 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-31898500

RESUMO

BACKGROUND: Due to the great burden of family and the conflicts among family, society and career roles resulting from migrant working, rural women suffer more conflicts between work and family and need more social attention. Previous studies of the conflicts between family and work mainly focus on the group of career women, and there is a lack of the research on the conflicts between work and family of rural women, which needs to be systematically and further studied. METHODS: This study used a sample survey of 380 rural women in rural areas of Sichuan Province to measure rural women's cognition of work-family, coordination and handling of conflicts, post-conflict choices, and subjective well-being; the study constructs an ordered multi-class logistic regression model to explore the impact of work-family conflict on the subjective well-being of rural women in rural regions. RESULTS: The study result shows that: (1) The level of subjective well-being of rural women is generally high, and 70% of women feel satisfied or very satisfied. (2) The factor which impacts the subjective well-being among rural women most is work-interfering-with-family conflict, followed by work-family balance and confidence in conflict coordination. CONCLUSION: This study can enhance our understanding of rural women in rural areas, and provide a reference for formulating policies to improve people's life satisfaction.


Assuntos
Autoavaliação Diagnóstica , Características da Família , Saúde Mental , Satisfação Pessoal , Migrantes/psicologia , Equilíbrio Trabalho-Vida/estatística & dados numéricos , Adulto , China/epidemiologia , Feminino , Humanos , Avaliação das Necessidades , População Rural , Fatores Socioeconômicos
4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-878788

RESUMO

Evaporative light scattering detector(ELSD) and charged aerosol detector(CAD) methods were established in this study for the content determination of four kinds of sugars in Zhusheyong Yiqi Fumai(YQFM), and the factors affecting the accuracy of CAD methods were discussed. HPLC-ELSD chromatographic separation was performed on a Shodex Asahipak NH2 P-50 column with acetonitrile-water(75∶25)as the mobile phase, with a flow rate of 0.8 mL·min~(-1), drift tube temperature of 80 ℃. The analysis by HPLC-CAD was performed on the same column with acetonitrile-water as mobile phase for gradient elution, with a flow rate of 0.8 mL·min~(-1), a neb temperature of 45 ℃, and power function(PF) of 1.3. The samples of YQFM were detected by ELSD and CAD respectively. It was found that YQFM was composed of fructose, glucose, sucrose and maltose. The linear relationship of the two methods was good, and the recoveries, reproducibility and stability of these four kinds of sugars measured by the two methods satisfied the requirements of methodology. Both CAD and ELSD detectors were accurate and reliable in detecting saccharides components in YQFM. In addition, it was revealed in this study for the first time that the PF parameter of CAD had an important influence on the accuracy of sugar determination and acted as the key parameter of CAD method. It was also found that for CAD, a non-linear detector, there was no significant difference between the results of linear regression and logarithmic regression.


Assuntos
Aerossóis , Carboidratos , Cromatografia Líquida de Alta Pressão , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação , Açúcares
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-873260

RESUMO

Objective::To establish the quality control method for multi-index content determination and fingerprint of salvianolic acids. Method::Agilent ZORBAX SB-C18 (4.6 mm×250 mm, 5μm) column was adopted, with 0.1%formic acid-water as mobile phase A and 0.1%formic acid-acetonitrile as mobile phase B for gradient elution (0-30 min, 20%-21.5%B; 30-35 min, 21.5%-25%B; 35-45 min, 25%-40%B; 45-50 min, 40%-95%B). The column temperature was set at 30 ℃, the flow rate was set at 1 mL·min-1, and the detection wavelength was set at 288 nm. Relative correction factors of caffeic acid, salvianolic acid E, rosmarinic acid, lithosperic acid, salvianolic acid B and salvianolic acid Y were determined by the concentration method. The content of each indicator component of the reference extract of salvianolic acid polyphenolic acid was determined and compared with the results of the monomer reference substance by the external standard method. At the same time, the fingerprint method was established. and the similarity evaluation was carried out on 10 batches of extracts. Result::Caffeic acid, salvianolic acid E, rosmarinic acid, lithospermic acid, salvianolic acid B, and salvianolic acid Y had a good linear relationship within the respective detection mass concentration ranges (r>0.999 9). The injection precision RSD was 0.1%-1.2%, the reproducible RSD was 1.2%-1.6%, and the recovery of the six components was 82.03%-98.68%. The stability of each component in the sample solution was good within 36 h. The relative correction factors for each indicator component were determined to be caffeic acid (2.92), salvianolic acid E (1.10), rosmarinic acid (1.61), lithosperic acid (1.07), salvianolic acid B (1.00), salvianolic acid Y (0.83). The effects of different methods, concentrations, instruments, columns, wavelengths were investigated, and the measured relative correction factors were found to be suitable. The results of the calibration factor method and the monomer standard reference substance method were less different. The HPLC fingerprints of the reference extract of salvianolic acids were established, and five common characteristic peaks were determined. The chromatographic peaks were confirmed according to the reference substance. The similarity of the fingerprints of the 10 batches of extracts was higher, and the quality difference was smaller. Conclusion::The multi-index content determination method and the fingerprint method established in this study are simple, rapid, accurate and reproducible, and can be used for quality control of Salviae miltiorrhizae Radix et Rhizoma polyphenolic acid reference extract.

6.
RSC Adv ; 9(36): 20687-20697, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35515524

RESUMO

In this work, we prepared an iron-based frictional material from vanadium-bearing titanomagnetite concentrates by in situ carbothermic reaction with improved tribological properties. Effects of different amounts of rare-earth oxides on the microstructure and properties of the Fe-based friction materials were investigated. The microstructure of the Fe-based friction material consisted of an Fe matrix, hard particles (mainly TiC) and a lubricating phase (graphite). The moderate addition of rare-earth oxides improved the microstructure and properties of the Fe-based friction material significantly. Particularly, the friction coefficient decreased from 0.61 to 0.48-0.56 and the wear rate reduced from 7.8 × 10-7 cm3 J-1 to 2.6 × 10-7∼4.9 × 10-7 cm3 J-1. Addition of La2O3 (≤0.2 wt%) or CeO2 (≤0.4 wt%) contributed to sintering densification and improved the relative density, hardness and wear resistance. The dominant wear mechanism changes from severe abrasive wear and oxidative wear to mild oxidative wear. However, when rare-earth oxide addition was increased further, the microstructure, relative density, hardness, and wear performance of the Fe-based friction materials deteriorated. Consequently, the optimal additions of La2O3 and CeO2 were 0.2 wt% and 0.4 wt%, respectively.

7.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1008419

RESUMO

The purpose of this study was to investigate the feasibility of the salvianolic acids reference extract for quality control for Salvia miltiorrhiza and salvianolic acids for injection. An Agilent ZORBAX SB-C18( 4. 6 mm×250 mm,5 μm) column was used with mobile phase consisting of 0. 1% formic acid-water and 0. 1% formic acid-acetonitrile in gradient elution procedure. The column temperature was 30 ℃; the flow rate was 1 m L·min-1; and the detection wavelength was 288 nm. The content of rosmarinic acid,lithospermic acid and salvianolic acid B in S. miltiorrhiza was determined by using the salvianolic acids reference extract as control substance. The content of caffeic acid,salvianolic acid E,rosmarinic acid,lithospermic acid,salvianolic acid B,and salvianolic acid Y in the salvianolic acids for injection was also determined. The linear relationship between chemicals was good( r>0. 998 9),and the injection precision RSD was 0. 30%-0. 90%. The sexual RSD is between 1. 4% and 3. 0%,and the RSD of the reproducibility of the extract is between 2. 1% and 5. 2%. The recovery rate of the three components in S. miltiorrhiza was 96. 80%-99. 20%,and the recovery rate of the six components in salvianolic acids for injection was 88. 90%-107. 5%. The solution of S. miltiorrhiza and salvianolic acids for injection were stable within 48 h. A total of 8 batches of S. miltiorrhiza and injection were determined by the reference extract,and the difference was smaller than that measured by the monomer control. This study preliminarily verified that the salvianolic acids reference extract can be used as a substitute for the monomer control for the quality control of S. miltiorrhiza and salvianolic acids for injection.


Assuntos
Alcenos/análise , Cromatografia Líquida de Alta Pressão , Medicamentos de Ervas Chinesas/normas , Polifenóis/análise , Controle de Qualidade , Reprodutibilidade dos Testes , Salvia miltiorrhiza/química
8.
RSC Adv ; 8(64): 36503-36511, 2018 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-35558919

RESUMO

In this work, we prepared an iron-based frictional material from vanadium-bearing titanomagnetite concentrates by in situ carbothermic reaction with improved tribological properties. Effects of Mn content (1-4 wt%) on the microstructure and properties of iron-based friction material were investigated. The microstructure and properties of iron-based friction material with Mn are significantly improved. In particular, the friction coefficient decreases from 0.54 to 0.40-0.49 and the wear rate reduces from 1.899 × 10-7 cm3 J-1 to 0.229 × 10-7 cm3 J-1 - 1.309 × 10-7 cm3 J-1. Appropriate Mn addition (1-3 wt%) contributes efficiently to the sintering densification and increasing laminated pearlites. Comparatively, the density, hardness and wear resistance are improved. The dominant wear mechanism changes from severe abrasive wear to mild abrasive wear and oxidative wear is also enhanced. However, when Mn content increases to 4 wt%, the microstructure, relative density, hardness and wear performance of iron-based friction material are deteriorated. Consequently, the optimal addition of Mn is 3 wt% in the iron-based friction material.

9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-335764

RESUMO

To establish an on-line monitoring method for extraction process of Schisandrae Chinensis Fructus, the formula medicinal material of Yiqi Fumai lyophilized injection by combining near infrared spectroscopy with multi-variable data analysis technology. The multivariate statistical process control (MSPC) model was established based on 5 normal batches in production and 2 test batches were monitored by PC scores, DModX and Hotelling T2 control charts. The results showed that MSPC model had a good monitoring ability for the extraction process. The application of the MSPC model to actual production process could effectively achieve on-line monitoring for extraction process of Schisandrae Chinensis Fructus, and can reflect the change of material properties in the production process in real time. This established process monitoring method could provide reference for the application of process analysis technology in the process quality control of traditional Chinese medicine injections.

10.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-307119

RESUMO

Currently, near infrared spectroscopy (NIRS) has been considered as an efficient tool for achieving process analytical technology(PAT) in the manufacture of traditional Chinese medicine (TCM) products. In this article, the NIRS based process analytical system for the production of salvianolic acid for injection was introduced. The design of the process analytical system was described in detail, including the selection of monitored processes and testing mode, and potential risks that should be avoided. Moreover, the development of relative technologies was also presented, which contained the establishment of the monitoring methods for the elution of polyamide resin and macroporous resin chromatography processes, as well as the rapid analysis method for finished products. Based on author's experience of research and work, several issues in the application of NIRS to the process monitoring and control in TCM production were then raised, and some potential solutions were also discussed. The issues include building the technical team for process analytical system, the design of the process analytical system in the manufacture of TCM products, standardization of the NIRS-based analytical methods, and improving the management of process analytical system. Finally, the prospect for the application of NIRS in the TCM industry was put forward.

11.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-236009

RESUMO

To study and establish a monitoring method for macroporous resin column chromatography process of salvianolic acids by using near infrared spectroscopy (NIR) as a process analytical technology (PAT).The multivariate statistical process control (MSPC) model was developed based on 7 normal operation batches, and 2 test batches (including one normal operation batch and one abnormal operation batch) were used to verify the monitoring performance of this model. The results showed that MSPC model had a good monitoring ability for the column chromatography process. Meanwhile, NIR quantitative calibration model was established for three key quality indexes (rosmarinic acid, lithospermic acid and salvianolic acid B) by using partial least squares (PLS) algorithm. The verification results demonstrated that this model had satisfactory prediction performance. The combined application of the above two models could effectively achieve real-time monitoring for macroporous resin column chromatography process of salvianolic acids, and can be used to conduct on-line analysis of key quality indexes. This established process monitoring method could provide reference for the development of process analytical technology for traditional Chinese medicines manufacturing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...