Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Jpn Acad Ser B Phys Biol Sci ; 99(9): 352-388, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37952976

RESUMO

The present paper reviews recent activities on inverse analysis strategies in geotechnical engineering using Kalman filters, nonlinear Kalman filters, and Markov chain Monte Carlo (MCMC)/Hamiltonian Monte Carlo (HMC) methods. Nonlinear Kalman filters with finite element method (FEM) broaden the choices of unknowns to be determined for not only parameters but also initial and/or boundary conditions, and the use of the posterior probability of the state variables can be widely applied to, for example, the decision making for design changes. The relevance of the unknowns and the observed values and the selection of the best sensor locations are some of the considerations made while using the Kalman filter FEM. This paper demonstrates several real-world geotechnical applications of the nonlinear Kalman filter and the MCMC with FEM. Future studies should focus on the following areas: attaining excellent performance for long-term forecasts using short-term observation and developing a viable method for selecting equations that describe physical phenomena and constitutive models.


Assuntos
Teorema de Bayes , Método de Monte Carlo
2.
Sci Rep ; 13(1): 8386, 2023 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225824

RESUMO

The aim of this study was to obtain comprehensive data regarding the hemocompatibility of diamond-like carbon (DLC)-coated expanded polytetrafluoroethylene (ePTFE). DLC increased the hydrophilicity and smoothened the surface and fibrillar structure, respectively, of the ePTFE. DLC-coated ePTFE had more albumin and fibrinogen adsorption and less platelet adhesion than uncoated ePTFE. There were scarce red cell attachments in in vitro human and in vivo animal (rat and swine) whole blood contact tests in both DLC-coated and uncoated ePTFE. DLC-coated ePTFE had a similar but marginally thicker band movement than uncoated-ePTFE with SDS-PAGE after human whole blood contact test. In addition, survival studies of aortic graft replacement in rats (1.5 mm graft) and arteriovenous shunt in goats (4 mm graft) were performed to compare the patency and clot formation between DLC-coated and uncoated ePTFE grafts. Comparable patency was observed in both animal models. However, clots were observed in the luminal surface of the patent 1.5 mm DLC-coated ePTFE grafts, but not in that of uncoated ePTFE grafts. In conclusions, hemocompatibility of DLC-coated ePTFE was high and comparable to that of uncoated ePTFE. However, it failed to improve the hemocompatibility of 1.5 mm ePTFE graft probably because increased fibrinogen adsorption canceled the other beneficial effects of DLC.


Assuntos
Albuminas , Prótese Vascular , Humanos , Animais , Ratos , Suínos , Adsorção , Carbono , Fibrinogênio , Cabras
3.
J Cardiol Cases ; 20(1): 35-38, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31320952

RESUMO

The majority of marathon deaths are caused by sudden cardiac arrest (SCA), which occur in approximately 1 in 57,000 runners. Such deaths are more common among older males and usually occur in the last 4 miles of the racecourse. Although prompt resuscitation, including early use of an automated external defibrillator (AED), improves survival, the deployment of enough trained medical staff and AEDs is difficult due to increased cost. Moreover, most victims of exercise-related SCA have no premonitory symptoms. Therefore, we tried to use a novel approach to prevent sudden cardiac deaths (SCD) related to SCA using real-time electrocardiographic tele-monitoring system, as an initial trial to assess operative possibility in a full marathon. As a result, 3 out of 5 runners had reasonable measurement results and sufficient tele-monitoring without complications related to this trial was possible. However, many investigations and improvements, such as improving cost-effectiveness, reducing noise, and automating the monitoring system, are needed for practical application of these devices for athletes. As a next step, we would establish a novel strategy to reduce SCDs in athletes using next-generation devices, which include an alarm system associated with early application of AED. .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...