1.
IEEE Trans Biomed Eng ; 66(3): 647-655, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29993484

RESUMO

OBJECTIVE: To both qualitatively and quantitatively investigate corneal biomechanical properties through an ultrasonic microelastography imaging system, which is potentially useful in the diagnosis of diseases, such as keratoconus, postrefractive keratectasia, and tracking treatment such as cross-linking surgery. METHODS: Our imaging system has a dual-frequency configuration, including a 4.5 MHz ring transducer to push the tissue and a confocally aligned 40 MHz needle transducer to track micron-level displacement. Two-dimensional/three-dimensional acoustic radiation force impulse (ARFI) imaging and Young's modulus in the region of interest were performed on ex vivo porcine corneas that were either cross-linked using formalin solution or preloaded with intraocular pressure (IOPs) from 5 to 30 mmHg. RESULTS: The increase of corneal stiffness and the change in cross-linked volume following formalin crosslinking could be precisely observed in the ARFI images and reflected by the reconstructed Young's modulus while the B-mode structural images remained almost unchanged. In addition, the relationship between the stiffness of the cornea and IOPs was investigated among 12 porcine corneas. The corneal stiffness is significantly different at various IOPs and has a tendency to become stiffer with increasing IOP. CONCLUSION: Our results demonstrate the principle of using ultrasonic microelastography techniques to image the biomechanical properties of the cornea. Integrating high-resolution ARFI imaging labeled with reconstructed Young's modulus and structural imaging of the cornea can potentially lead to a routinely performed imaging modality in the field of ophthalmology.


Assuntos
Córnea/diagnóstico por imagem , Córnea/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Animais , Módulo de Elasticidade , Pressão Intraocular/fisiologia , Suínos
2.
Sensors (Basel) ; 18(8)2018 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-30096810

RESUMO

In this article, an approach to designing and developing an ultrahigh frequency (≤600 MHz) ultrasound analog frontend with Golay coded excitation sequence for high resolution imaging applications is presented. For the purpose of visualizing specific structures or measuring functional responses of micron-sized biological samples, a higher frequency ultrasound is needed to obtain a decent spatial resolution while it lowers the signal-to-noise ratio, the difference in decibels between the signal level and the background noise level, due to the higher attenuation coefficient. In order to enhance the signal-to-noise ratio, conventional approach was to increase the transmit voltage level. However, it may cause damaging the extremely thin piezoelectric material in the ultrahigh frequency range. In this paper, we present a novel design of ultrahigh frequency (≤600 MHz) frontend system capable of performing pseudo Golay coded excitation by configuring four independently operating pulse generators in parallel and the consecutive delayed transmission from each channel. Compared with the conventional monocycle pulse approach, the signal-to-noise ratio of the proposed approach was improved by 7⁻9 dB without compromising the spatial resolution. The measured axial and lateral resolutions of wire targets were 16.4 µm and 10.6 µm by using 156 MHz 4 bit pseudo Golay coded excitation, respectively and 4.5 µm and 7.7 µm by using 312 MHz 4 bit pseudo Golay coded excitation, respectively.

3.
Sci Rep ; 6: 37554, 2016 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-27874052

RESUMO

Non-contact precise manipulation of single microparticles, cells, and organisms has attracted considerable interest in biophysics and biomedical engineering. Similar to optical tweezers, acoustic tweezers have been proposed to be capable of manipulating microparticles and even cells. Although there have been concerted efforts to develop tools for non-contact manipulation, no alternative to complex, unifunctional tweezer has yet been found. Here we report a simple, low-cost, multifunctional single beam acoustic tweezer (SBAT) that is capable of manipulating an individual micrometer scale non-spherical cell at Rayleigh regime and even a single millimeter scale organism at Mie regime, and imaging tissue as well. We experimentally demonstrate that the SBAT with an ultralow f-number (f# = focal length/aperture size) could manipulate an individual red blood cell and a single 1.6 mm-diameter fertilized Zebrafish egg, respectively. Besides, in vitro rat aorta images were collected successfully at dynamic foci in which the lumen and the outer surface of the aorta could be clearly seen. With the ultralow f-number, the SBAT offers the combination of large acoustic radiation force and narrow beam width, leading to strong trapping and high-resolution imaging capabilities. These attributes enable the feasibility of using a single acoustic device to perform non-invasive multi-functions simultaneously for biomedical and biophysical applications.


Assuntos
Acústica , Engenharia Biomédica/métodos , Pinças Ópticas , Ovário/diagnóstico por imagem , Animais , Engenharia Biomédica/instrumentação , Fenômenos Biofísicos , Feminino , Humanos , Micromanipulação , Som , Peixe-Zebra/anatomia & histologia
4.
Biotechnol Bioeng ; 108(7): 1643-50, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21328319

RESUMO

Various techniques exerting mechanical stress on cells have been developed to investigate cellular responses to externally controlled stimuli. Fundamental mechanotransduction processes about how applied physical forces are converted into biochemical signals have often been examined by transmitting such forces through cells and probing its pathway at cellular levels. In fact, many cellular biomechanics studies have been performed by trapping (or immobilizing) individual cells, either attached to solid substrates or suspended in liquid media. In that context, we demonstrated two-dimensional acoustic trapping, where a lipid droplet of 125 µm in diameter was directed transversely toward the focus (or the trap center) similar to that of optical tweezers. Under the influence of restoring forces created by a 30 MHz focused ultrasound beam, the trapped droplet behaved as if tethered to the focus by a linear spring. In order to apply this method to cellular manipulation in the Mie regime (cell diameter > wavelength), the availability of sound beams with its beamwidth approaching cell size is crucial. This can only be achieved at a frequency higher than 100 MHz. We define ultrasound beams in the frequency range from 100 MHz to a few GHz as ultrasound microbeams because the lateral beamwidth at the focus would be in the micron range. Hence a zinc oxide (ZnO) transducer that was designed and fabricated to transmit a 200 MHz focused sound beam was employed to immobilize a 10 µm human leukemia cell (K-562) within the trap. The cell was laterally displaced with respect to the trap center by mechanically translating the transducer over the focal plane. Both lateral displacement and position trajectory of the trapped cell were probed in a two-dimensional space, indicating that the retracting motion of these cells was similar to that of the lipid droplets at 30 MHz. The potential of this tool for studying cellular adhesion between white blood cells and endothelial cells was discussed, suggesting its capability as a single cell manipulator.


Assuntos
Técnicas Citológicas/métodos , Ultrassom/métodos , Adesão Celular , Linhagem Celular Tumoral , Células Imobilizadas , Células Endoteliais/fisiologia , Humanos , Leucócitos/fisiologia
5.
J Am Ceram Soc ; 92(6): 1276-1279, 2009 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-20376196

RESUMO

The use of PZT films in sliver-mode high-frequency ultrasonic transducers applications requires thick, dense, and crack-free films with excellent piezoelectric and dielectric properties. In this work, PZT composite solutions were used to deposit PZT films >10 µm in thickness. It was found that the functional properties depend strongly on the mass ratio of PZT sol-gel solution to PZT powder in the composite solution. Both the remanent polarization, P(r), and transverse piezoelectric coefficient, e(31,) (f), increase with increasing proportion of the sol-gel solution in the precursor. Films prepared using a solution-to-powder mass ratio of 0.5 have a remanent polarization of 8 µC/cm(2), a dielectric constant of 450 (at 1 kHz), and e(31,) (f) = -2.8 C/m(2). Increasing the solution-to-powder mass ratio to 6, the films were found to have remanent polarizations as large as 37 µC/cm(2), a dielectric constant of 1250 (at 1 kHz) and e(31,) (f) = -5.8 C/m(2).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...