Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Haematol ; 117(2): 115-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17127819

RESUMO

A transient aplastic crisis (TAC) is a well-known complication in all types of chronic hemolytic anemia but only 2 cases of such an event were described in congenital dyserythropoietic anemias (CDAs). Here, we report a third case, and by retrospective chart review of 78 cases we found evidence of TAC in 8 further patients with CDA II, with serological evidence of previous human parvovirus B19 (B19V) infection in all but one. Although B19V infection results in TAC in only a minority of patients with CDA, physicians responsible for these patients should be aware of such a potentially life-threatening complication. Testing for B19V-specific IgG is recommended in patients with CDA to estimate the risk of a possible future aplastic crisis.


Assuntos
Anemia Diseritropoética Congênita/complicações , Aplasia Pura de Série Vermelha/etiologia , Adolescente , Adulto , Idoso , Anticorpos Antivirais/análise , Criança , Pré-Escolar , Feminino , Humanos , Pessoa de Meia-Idade , Infecções por Parvoviridae/sangue , Infecções por Parvoviridae/complicações , Parvovirus B19 Humano/imunologia
2.
Praxis (Bern 1994) ; 88(43): 1751-8, 1999 Oct 21.
Artigo em Alemão | MEDLINE | ID: mdl-10568352

RESUMO

Ambulatory blood pressure monitoring (ABPM) over 24 hours was compared to two blood pressure measurements taken in the morning by the 22 test persons themselves. ABPM was carried out at the beginning and the end of the study using a spacelabs SL 90207 apparatus. A semiautomatic sphygmomanometer was used for self-measurements (Visomat OZ 2). Monitored systolic and diastolic 24 hour values and the mean 24 hour value were on the average slightly higher than the self-measured pressures. Both methods yielded almost constant values over the test period. The mean of self-measured systolic and diastolic values from the second measurement over the entire two week period was significantly lower than the initially registered values (p < 0.001). Therefore a high correlation (r = 0.88, p < 0.001) was found between the mean systolic value of the second self-measurement with the mean ABPM 24 hour value; the corresponding correlation for the first measurement with ABPM was lower (r = 0.84, p < 0.01). The correlation of the diastolic values with ABPM was also lower (r = 0.70, p < 0.01). These results show that ABPM and self-measurements in the morning differ only slightly. The use and reliability of semiautomatic blood pressure measuring devices provide a practicable and economic alternative to ABPM.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Autocuidado , Adulto , Idoso , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitorização Ambulatorial da Pressão Arterial/métodos , Monitores de Pressão Arterial , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...