Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
JACC Clin Electrophysiol ; 10(6): 1078-1086, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703164

RESUMO

BACKGROUND: In patients with persistent atrial fibrillation (PerAF), antiarrhythmic drugs (AADs) are considered a first-line rhythm-control strategy, whereas catheter ablation is a reasonable alternative. OBJECTIVES: This study sought to examine the prevalence, patient characteristics, and clinical outcomes of patients with PerAF who underwent catheter ablation as a first or second-line strategy. METHODS: This multicenter observational study included consecutive patients with PerAF who underwent first-time ablation between January 2020 and September 2021 in 9 medical centers in the United States. Patients were divided into those who underwent ablation as first-line therapy and those who had ablation as second-line therapy. Patient characteristics and clinical outcomes were compared between the groups. RESULTS: A total of 2,083 patients underwent first-time ablation for PerAF. Of these, 1,086 (52%) underwent ablation as a first-line rhythm-control treatment. Compared with patients treated with AADs as first-line therapy, these patients were predominantly male (72.6% vs 68.1%; P = 0.03), with a lower frequency of hypertension (64.0% vs 73.4%; P < 0.001) and heart failure (19.1% vs 30.5%; P < 0.001). During a mean follow-up of 325.9 ± 81.6 days, arrhythmia-free survival was similar between the groups (HR: 1.13; 95% CI: 0.92-1.41); however, patients in the second-line ablation strategy were more likely to continue receiving AAD therapy (41.5% vs 15.9%; P < 0.001). CONCLUSIONS: A first-line ablation strategy for PerAF is prevalent in the United States, particularly in men with fewer comorbidities. More data are needed to identify patients with PerAF who derive benefit from an early intervention strategy.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Masculino , Ablação por Cateter/estatística & dados numéricos , Feminino , Pessoa de Meia-Idade , Idoso , Antiarrítmicos/uso terapêutico , Resultado do Tratamento , Estados Unidos/epidemiologia
2.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

3.
Am J Surg ; 226(2): 233-238, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37301644

RESUMO

BACKGROUND: Postoperative ostomy reversal hernias are common and can create strain on the healthcare system. There is little literature evaluating the utilization of absorbable mesh following ostomy reversal. The effect on subsequent hernia rates at our institution has not been evaluated. We examine if the addition of absorbable mesh decreases the postoperative hernia rate in our patient population. METHODS: We performed a retrospective review of all ileostomy and colostomy reversals. Patients were divided into two groups based on whether an absorbable mesh was used at ostomy closure or not. RESULTS: Hernia recurrence rates were lower in the group that had mesh reinforcement (8.96%) vs the group that did not receive a mesh (14.8%) though this was not statistically significant (p = 0.233). CONCLUSION: Prophylactic use of an absorbable biosynthetic mesh did not alter the rate of incisional hernia rates following ostomy reversal in our cohort of patients.


Assuntos
Hérnia Ventral , Hérnia Incisional , Estomia , Humanos , Colostomia , Hérnia , Hérnia Ventral/prevenção & controle , Hérnia Ventral/cirurgia , Hérnia Incisional/epidemiologia , Hérnia Incisional/etiologia , Hérnia Incisional/prevenção & controle , Estomia/efeitos adversos , Telas Cirúrgicas
4.
Heart Rhythm O2 ; 4(12): 784-793, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204461

RESUMO

Background: Catheter ablation is an established therapy for paroxysmal atrial fibrillation (PAF). The TactiFlex Ablation Catheter, Sensor Enabled (TactiFlex SE) is a next-generation radiofrequency ablation catheter incorporating fiber optics-based contact force-sensing technology with a flexible, laser-cut tip. Objective: The study sought to evaluate the safety and effectiveness of the TactiFlex SE ablation catheter for treatment of drug-refractory PAF. Methods: The TactiFlex AF investigational device exemption was a prospective, nonrandomized, multicenter clinical study. Enrollment began on June 26, 2020 and completed June 18, 2021. Subjects with PAF underwent de novo pulmonary vein isolation and, if indicated, ablation for typical atrial flutter. Subjects were followed for 12 months. Results: Of the 355 subjects enrolled at 37 sites worldwide, 334 underwent ablation with the TactiFlex SE catheter. The Kaplan-Meier estimate of 12-month freedom from AF/atrial flutter (AFL)/atrial tachycardia recurrence was 72.9% (95% confidence interval [CI] 95% CI 67.2%-77.8%) and clinical success was 83.6% (95% CI 95% CI 78.1%-87.2%). As-treated analyses compared subjects treated at high power (left atrium time-averaged power setting 40-50 W; n = 222) vs low power (<40 W; n = 97). The Kaplan-Meier estimate of 12-month freedom from AF/AFL/atrial tachycardia recurrence was 76.4% (95% CI 69.3%-82.0%) and clinical success was 83.9% (95% CI 77.5%-88.6%) in the high-power group compared with 66.8% (95% CI 56.1%-75.5%) and 80.7% (95% CI 70.8%- 87.5%), respectively, in the low-power group. The primary safety event rate in all treated subjects was 4.3%; 4.1% in the HP group and 5.2% in the LP group (P = .7671). Conclusion: TactiFlex SE is safe and effective for treatment of drug-refractory PAF and concomitant AFL and enables more efficient procedures than previous generation catheters.

5.
J Interv Card Electrophysiol ; 65(1): 141-151, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35536500

RESUMO

BACKGROUND: The EnSite Precision™ cardiac mapping system (Abbott) is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor-enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3D maps of cardiac chambers. The EnSite Precision™ Observational Study (NCT-03260244) was designed to quantify and characterize the use of the EnSite Precision™ cardiac mapping system for mapping and ablation of cardiac arrhythmias in a real-world environment and evaluate procedural outcomes. METHODS: A total of 1065 patients were enrolled at 38 centers in the USA and Canada between 2017 and 2018 and were followed for 12 months post procedure for arrhythmia recurrence, medication use, and quality-of-life changes. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedure using the EnSite Precision™ System. RESULTS: A final cohort of 925 patients (64.3 years of age, 30.2% female) were analyzed. The primary procedural indication was atrial flutter in 48.1% (445/925), atrial fibrillation in 46.5% (430/925), and other arrhythmias in 5% (50/925). Electroanatomic mapping was performed in 81.5% (754/925) of patients. Mapping was stable throughout 79.8% (738/925) of procedures with initial mapping time of 8.6 min (IQR 4.7-15.0). Average mapping efficiency created with AutoMap or TurboMap was 164.9 ± 365.7 used points per minute. Median number of mapping points collected and used was 1752.5 and 811.0, respectively. Only 335/925 (36.2%) required editing and 66.0% (221/335) of these patients required editing of less than 10 points. Fluoroscopy was utilized in most cases (n = 811/925, 87.4%) with fluoroscopy time of 11.0 min (IQR 6.0-18.0). Overall median procedure time was 101.0 min (IQR 59.0-152.0). Acute procedural success was high for both atrial fibrillation (n = 422/430, 98.1%) and atrial flutter (n = 434/445, 97.5%). CONCLUSION: In a real-world study analysis, use of the EnSite Precision™ mapping system was associated with high procedural stability, short mapping times, high point density requiring infrequent editing, low fluoroscopy time, and high prevalence of acute procedural success.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Eletrofisiologia Cardíaca , Ablação por Cateter/métodos , Feminino , Fluoroscopia , Humanos , Masculino , Resultado do Tratamento
6.
Curr Trop Med Rep ; 9(2): 61-71, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402142

RESUMO

Purpose of Review: In response to the COVID-19 pandemic, there has been a remarkably accelerated development of vaccines worldwide. However, an effective distribution system is crucial for vaccination at a national level. Ecuador was one of the first Latin American countries to be most severely affected by the pandemic. It has been struggling to expand its vaccination drive and requires a strategy that provides an achievable vaccination rate and maintains its primary care services. This study aims to provide an efficient vaccination model to achieve herd immunity by utilizing the country's existing infrastructure (the centralized electoral system) for mass vaccination. Recent Findings: The national electoral data from 2017 and 2021 were used to create estimates for the proposed vaccination model. Two model variations, total personnel, needed, and the number of days needed to vaccinate 50%, 75%, and 100% of the population were considered. The numbers of vaccines needed, and vaccination sites were estimated based on the current number of registered voters and polling stations. The results from the proposed model show that 17,892,353 people can be vaccinated, at 40,093 polling stations, by 90,209 personnel if one vaccinator was available per polling station. Summary: Based on this model, even a conservative estimate shows that 12.56 days are needed to achieve herd immunity, and 16.74 days are needed to vaccinate the entire population of Ecuador. Additionally, we propose that this vaccination model can be used as a blueprint for any country to address similar catastrophes in the future. Supplementary Information: The online version contains supplementary material available at 10.1007/s40475-022-00251-y.

7.
Cureus ; 13(10): e18630, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34786230

RESUMO

Introduction Trauma patients frequently return to an emergency department (ED) soon after discharge; often for non-urgent reasons. Social factors contribute to higher ED usage. At present, there is no standardized system for reporting of ED visits and readmissions among trauma care. We hypothesized that victims of violent crime suffer from many early post-discharge adverse events that has not been captured by current methods. Methods We prospectively consented and enrolled injured patients from January 1st, 2019 to December 31st, 2019. We documented 30-day post-discharge events using post-discharge phone calls and detailed chart abstraction. Patients were categorized as victims of violence (VV) or unintentional traumatic injury (UT). Results During the study period, 444 patients were enrolled. Fifty-one (11.5%) were victims of violence and 393 (88.5%) experienced unintentional injuries. The VV patients were younger (40.10 vs 60.36; p<0.0001), and more predominantly male (92.16% vs 57.51%; p<0.0001). Total injury severity score (ISS), critical care length of stay (LOS), and total LOS were similar. VV patients were more likely discharged home (70.59% vs 55.47%; p=0.0403). They were significantly more likely to return to an emergency department (47.06% vs 23.16%; p<0.0005) and had more total number of ED visits per patient. Readmission rates, however, were not different (21.57% vs 16.28%; p=NS). The VV patients more frequently were underinsured (72.5%, vs 20.6%, p<0.005). Discussion Victims of violence presented to the ED significantly more often, despite similar injury scores, LOS, and being of younger age. Of these patients, only 26.2% of ED presentations resulted in readmission, suggesting the majority of patient complaints may have been able to be managed in an office-based setting. VV had significantly more underinsured or subsidized patients. Victims of violence are vulnerable and may benefit from more resources provided in the early post-discharge period.

8.
Cureus ; 13(10): e18789, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34804655

RESUMO

Introduction Firearm homicide is a leading cause of violence-related death in the United States.Unfortunately, more than 80% of illegal firearm discharges are never reported to police by traditional means.ShotSpotterTM (Newark, California) is an acoustic firearm event detection system that can localize gunfire, prompting police, and subsequent emergency medical services (EMS) presence. Previously reported healthcare effects of acoustic detection are speculative in nature. We sought to investigate Hartford, Connecticut's experience with ShotSpotter​​​​​​​TM given its smaller size and broad coverage.  Methods The three trauma centers in Hartford (two for adults and one for pediatric) collaborated with the Hartford Police to review outcomes of victims with acoustically detected gunshots and compare them to those who went undetected. We performed a retrospective review of patients who presented with gunshot wounds (GSW) over a 30-month period, from January 1, 2016 to June 30, 2018. Victim location and acoustic detection were reconciled by the police department and hospital staff independently. Patients were individually matched for location, prehospital response, treatment durations, and hospital outcomes. Results Of 387 GSW, 157 (40.6%) presented via EMS and were included in the sample. Of these, 89 correlated to a detection event (56.7%) and 68 had no correlating event (43.3%). These two groups had no difference in prehospital treatment times, scene and transport duration, and injury severity. Further, the need for surgery or transfusion, lengths of stay, and disposition, including mortality, did not differ. Conclusions Despite limited previous reports demonstrating conferred benefits to acoustic detection of gunshots, Hartford's experience showed no benefit. The potential for such systems to act as early warning systems is evident but may depend on a city's resources, geography, and technology.

9.
JACC Clin Electrophysiol ; 7(8): 1013-1021, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33812831

RESUMO

OBJECTIVES: The objective of this clinical trial was to evaluate the safety and effectiveness of the TactiCath Contact Force Ablation Catheter, Sensor Enabled (TactiCath SE) (Abbott, Abbott Park, Illinois) for the treatment of drug-refractory, symptomatic paroxysmal atrial fibrillation (PAF). BACKGROUND: Catheter ablation of atrial fibrillation (AF) is an established therapy for the treatment of PAF. Ablation technology is evolving with the primary goals of improving efficacy and safety of the procedure. METHODS: This was a multicenter single-arm trial evaluating a novel ablation catheter for the treatment of PAF. A total of 156 subjects were enrolled at 19 sites in the United States, Europe, and Australia. The primary safety endpoint was the rate of device- or procedure-related serious adverse events occurring within 7 days. The primary effectiveness endpoint was acute success defined as pulmonary vein isolation at 30 min after ablation. Two descriptive endpoints were prospectively captured: 1) 1-year freedom from recurrence of symptomatic AF, atrial flutter (AFL), and atrial tachycardia (AT) lasting ≥30 s without a new or increased dose of Class I/III antiarrhythmic drugs; and 2) 1-year drug-free success defined by the absence of any recurrent AF/AFL/AT lasting ≥30 s without using Class I/III antiarrhythmic drugs. RESULTS: Primary safety events occurred in 4.7% of patients (95% confidence interval [CI]: 2.23% to 8.64%), and the procedure was acutely successful in 98.0% of patients (95% CI: 94.95% to 99.46%). According to Kaplan-Meier estimates at 1 year, 82.2% (95% CI: 74.7% to 87.6%) were free from symptomatic recurrence, and 1-year drug-free success was 68.2% (95% CI: 59.9% to 75.1%). CONCLUSIONS: The TactiCath™ Contact Force Ablation Catheter, Sensor Enabled™ is safe and effective for the treatment of paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/cirurgia , Recidiva
10.
IEEE Trans Biomed Eng ; 68(7): 2110-2116, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32960760

RESUMO

BACKGROUND: Peri-device leak (PDL) following left atrial appendage occlusion (LAAO) may lead to an increased risk of thrombosis. However, current modalities for PDL detection, such as trans-esophageal echo (TEE) and cardiac CT do not provide quantitative measures of PDL. OBJECTIVE: to use dielectric imaging (DI) to measure PDL from a Watchman (WM) LAAO device. METHODS: A conductivity contrast agent is injected into the left atrium (LA) through the WM delivery system, while making DI measurements. Recordings are analyzed with a two-compartment model and the flow from the left atrial appendage (LAA) characterized by a "% clearance / beat" (CPB) parameter. With ethics approval, four dogs (26 ± 1.8  kg) were anesthetized and ventilated. Body-surface electrodes were placed and impedance data continuously acquired. WM devices (0-35% oversized) were introduced and placed into the LAA. During the study, the WM was either fully or partial deployed. At each deployment level, 10 mL of conductivity contrast was injected through the WM delivery sheath. At twenty-two deployment conditions, Doppler-flow TEE measurements were made, and compared to the DI-based value. RESULTS: In all cases, CPB values correctly predicted the TEE-based assessment of PDL (100% sensitivity/specificity). The TEE leak size also corresponded to CPB values with a correlation of r = 0.914 (p 0.001). CONCLUSION: Using DI signals, the leak flow from the WM LAAO can be measured and yields comparative results to TEE for detection of PDL. The DI method requires no other imaging modality or ionizing radiation and iodine contrast agent injection.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Animais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco , Cães , Ecocardiografia Transesofagiana , Resultado do Tratamento
11.
Egypt Heart J ; 72(1): 12, 2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32193785

RESUMO

BACKGROUND: Arterial stiffness is an independent predictor of cardiovascular disease (CVD) morbidity and mortality. A risk factor-independent association of arterial stiffness with traditional lipids has been described extensively, but it is still unclear whether an independent relationship exists between arterial stiffness and particles of lipoprotein subclasses. METHODS: The Baptist Employee Healthy Heart Study (BEHHS) is a lifestyle intervention study examining the effects of web-based programs on reducing CVD risk in high-risk persons. Participants had their brachial arterial augmentation index (AI, a measure arterial stiffness) assessed using the EndoPAT 2000 device. Cardio IQ™ ion mobility lipoprotein fractionation was utilized for measurement of particles of lipoprotein subclasses. RESULTS: The population consisted of 182 participants, (74% women, 49% Hispanic) with a mean age of 52 ± 9 years. There was a significant trend association between quartiles of AI and total cholesterol, HDL-c, large LDL-p, small IDL-p, large IDL-p, and all subclasses of HDL particles (total HDL-p, small HDL-p, and large HDL-p). In logistic regression analysis, only HDL-c, total LDL-p, large LDL-p, small IDL-p, large IDL-p, total HDL-p, small HDL-p, and large HDL-p demonstrated significant independent association with AI. CONCLUSION: Several lipoprotein subclasses demonstrate independent significant associations with arterial stiffness. A safe and relatively inexpensive blood test may be useful in identifying subclinical atherosclerosis process in a relatively young high CVD risk population. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01912209. Registered July 31, 2013.

12.
Heart Rhythm ; 16(12): 1883-1889, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31255845

RESUMO

BACKGROUND: Catheter navigation and 3-dimensional (3D) cardiac mapping are essential components of minimally invasive electrophysiological procedures. OBJECTIVE: The purpose of this study was to develop a novel 3D mapping system (KODEX - EPD, EPD Solutions, Best, The Netherlands) that measures changing electric field gradients induced on intracardiac electrodes to enable catheter localization and real-time 3D cardiac mapping. METHODS: We first validated the accuracy of the system's measurement and localization capabilities by comparing known and KODEX - EPD-measured distances and locations at 12 anatomical landmarks in both the atria and ventricles of 4 swine. Next, in vivo images of 3D porcine cardiac anatomy generated by KODEX - EPD and widely used CARTO 3 system (Biosense Webster, Inc., Diamond Bar, CA) were compared with gold standard computed tomography images acquired from the same animals. Finally, 3D maps of atrial anatomy were created for 22 patients with paroxysmal atrial fibrillation (Dielectric Unravelling of Radiofrequency ABLation Effectiveness trial). RESULTS: First, the mean error between known and measured distances was 1.08 ± 0.11 mm (P < .01) and the overall standard deviation between known and measured locations in 12 areas of the porcine heart was 0.35 mm (P < .01). Second, an expert comparison of 3D image quality revealed that KODEX - EPD is noninferior to CARTO 3. Third, the system enabled 3D imaging of atrial anatomy in humans, provided real-time images of atrioventricular valves, and detected important anatomical variations in a subset of patients. CONCLUSION: The KODEX - EPD system is a novel 3D mapping system that accurately detects catheter location and can generate high-resolution images without the need for preacquired imaging, specialty catheters, or a point-by-point mapping procedure.


Assuntos
Fibrilação Atrial , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Cirurgia Assistida por Computador , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Precisão da Medição Dimensional , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Avaliação de Resultados em Cuidados de Saúde , Ajuste de Prótese/instrumentação , Ajuste de Prótese/métodos , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Suínos
13.
Cardiol Ther ; : 357-364, 2019 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-31124018

RESUMO

INTRODUCTION: Transcatheter aortic valve replacement (TAVR) has become a widely accepted treatment option for patients with severe aortic stenosis (AS) who are considered intermediate- and high-risk surgical candidates. The purpose of this study was to test the hypothesis that trans-apical TAVR would be associated with increased risk of new-onset intraventricular conduction delay (LBBB or RBBB). METHODS: We conducted a retrospective observational study of consecutive patients undergoing TAVR at a large, single institution. The incidence of new LBBB or RBBB was compared between femoral and apical TAVR patients. Multivariate analysis was performed to account for confounding variables, which included age, gender, CAD, PAD, hypertension, and diabetes. RESULTS: A total of 467 TAVR patients were included in the study, with 283 (60.6%) femoral approach and 184 (39.4%) apical approach. In univariate analysis, the apical approach (when compared to the femoral approach) was associated with a higher incidence of both new-onset LBBB (12.79 vs. 3.40%, p = 0.0002) and RBBB (5.49 vs. 0.81%, p = 0.0039). After controlling for potential confounding variables, the apical approach continued to be associated with a higher incidence of both new-onset LBBB (p = 0.0010) and RBBB (p = 0.0115). There was also a trend towards an association between diabetes and new-onset LBBB (p = 0.0513) in apical TAVR patients. In subgroup analysis, LBBB/RBBB occurring as a result of transapical TAVR was associated with more frequent hospitalizations > 30 days after TAVR, compared to transfemoral TAVR. Other post-procedural complications noted more frequently among patients undergoing transapical TAVR include arrhythmias including atrial fibrillation, peri-procedural myocardial infarction (within 72 h), mortality from unknown cause, and mortality from non-cardiac cause. CONCLUSIONS: Relative to transfemoral TAVR, patients undergoing transapical TAVR are at increased risk for new-onset bundle branch block, peri-procedural myocardial infarction, rehospitalization, TAV-in-TAV deployment, and all-cause mortality at 1 year. Interventional cardiologists and cardiothoracic surgeons alike should take these findings into consideration when choosing which approach is most suitable for patients undergoing TAVR for severe aortic stenosis.

14.
Asian J Neurosurg ; 14(1): 126-130, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30937023

RESUMO

AIM: The aim of the study was to analyze the neurosurgical research output of Pakistan and compare it with that of developed countries. METHODOLOGY: We conducted a bibliometric analysis of publically available databases for all neurosurgical publications from Pakistan. All indexed peer-reviewed publications from January 2009 to December 2014 where at least one author was affiliated with any neurosurgical departments in Pakistan and research was conducted in Pakistan were selected. Manual and electronic search was done using MeSH terms to search for articles from Pakistan. Articles were then categorized according to design, subspecialty, region, and year. RESULTS: Our search identified 121 articles during the defined study period (mean = 20.16 ± 5.2 papers/year). A relatively constant increase was noticed for the last 6 years, i.e., 2009-2014. From the total 121 references, 100 (82.4%) publications were from one city, and on subanalysis, 80 (66.1%) were from a single institution. Three primary authors cumulatively contributed to 76 (62.8%) of these publications. Almost two-thirds (n = 76, 62.8%) of these publications were published in either regional or international journals while only 37.2% (n = 45) were published in local nonneurosurgery-specific journals. Only one study in the 6-year study period was with Level I evidence (meta-analysis). CONCLUSION: Neurosurgery research in Pakistan has shown modest improvement in terms of quality and quantity. Collaboration between various centers and channelizing different resources to create national data registries along with basic science laboratories is much needed.

16.
Surg Neurol Int ; 8: 226, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29026662

RESUMO

BACKGROUND: Postoperative meningitis is a growing cause of concern, especially with the evolution of multidrug-resistant organism. The authors evaluate the use of intraventricular/intrathecal (IVT/IT) antibiotics for postoperative gram-negative meningitis in patients whom intravenous antibiotics were ineffective. METHODS: Medical records were retrospectively reviewed and neurosurgery patients with gram-negative postoperative infection meningitis/ventriculitis were enrolled in the study. Their demographics, hospital course, and outcomes were recorded in a pro forma and analyzed using Statistical Package for the Social Sciences, version 19. RESULTS: The review identified 21 patients with postneurosurgical gram-negative meningitis/ventriculitis who were treated with IVT or IT antibiotics. The most common organism was Acinetobacter species (n = 14; 66%). Amikacin was used in 7 patients, polymyxin B in 9 patients, and colistin in 5 patients. A combination of antibiotics was used in one patient. Cerebrospinal fluid sterility was achieved in all patients with no incidence of relapse. There was a single death, though that was not related to the infectious process as the patient had a massive pulmonary embolism. CONCLUSION: The findings of this study suggest that IVT and IT antibiotic therapy is a useful option in patients who are nonresponsive to standard intravenous therapy with little or no side effects.

17.
Surg Neurol Int ; 8: 227, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29026663

RESUMO

BACKGROUND: High-grade gliomas have high infiltrative potential and spread along white matter and blood vessels. Enhancement of ependymal lining on magnetic resonance imaging (MRI) is considered as a marker of parenchymal spread of disease. In this study, we aimed to assess the sensitivity, specificity, and positive and negative predictive values of ependymal enhancement (EE) for identification of high-grade glial tumors. METHODS: We reviewed preoperative MRI scans of 94 consecutive patients surgically treated for space occupying lesions of the brain for EE. Assessment for EE was blind to the final histopathological diagnosis of the patient. An enhancement of more than 2 mm was considered positive. Pathologies of these patients were reviewed and matched to the radiological findings. Percentage and proportion of EE in glial and non-glial pathology groups was then calculated and a sensitivity and specificity analysis was performed. RESULTS: The population included 94 cases (64 males and 30 females) with population mean age 45 ± 15.5 years. Sensitivity of EE in differentiating glioma from total number of cases was 82.61% specificity 35.42% (P value = 0.048). EE had a sensitivity of 67.39% and specificity of 64.58% (P value = 0.002) in identifying high-grade glioma within the glioma group with a positive predictive value of 64.58% (95% CI: 49.46% to 77.83%), negative predictive value of 67.39% (95% CI: 51.98% to 80.46%). CONCLUSION: EE has moderate sensitivity and specificity for high-grade gliomas. However, larger sample studies are required for further validation of this observations.

18.
Cureus ; 9(4): e1188, 2017 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-28540143

RESUMO

BACKGROUND: Until recently, circulating micro-RNAs (miRNAs) have attracted major interest as novel biomarkers for the early diagnosis of coronary artery disease (CAD). This review article summarizes the available evidence on the correlation of micro-RNAs with both the clinical and subclinical coronary artery disease and highlights the necessity for exploring miRNAs as a potential diagnostic and prognostic biomarker of early CAD in an adult population. METHODS: A systematic literature analysis and retrieval online systems Public/Publisher MEDLINE/ Excerpta Medica Database /Medical Literature Analysis and Retrieval System Online,(PUBMED/EMBASE/MEDLINE) search were conducted for relevant information. Search was limited to the articles published in English language and conducted on humans, January 2000 onwards. We excluded studies of heart surgery, coronary artery bypass grafting (CABG), angioplasty and heart transplant. Eighteen studies met the inclusion criteria. RESULTS: Seven out of 18 studies were multivariate, i.e. adjusted for age, gender, body mass index (BMI), smoking, hypertension, diabetes, and blood lipid profiles, while the remaining twelve studies were univariate analysis. Different sources of miRNAs were used, i.e. plasma/serum, microparticles, whole blood, platelets, blood mononuclear intimal and endothelial progenitor cells were investigated. Fourteen out of 18 studies showed up-regulation of different miRNA in CAD patients and in vulnerable plaque disease. Four out of 18 studies showed both the up-regulation and down-regulation of miRNA in the population, while only three studies showed down-regulation of miRNA. Various sources and types of miRNA were used in each study. CONCLUSION: This review gives an extensive overview of up-regulation and down-regulation of miRNA in CAD and non-CAD patients. The pattern of miRNA regulation with respect to CAD/non-CAD study subjects varies across individual studies and different parameters, which could be the possible reason for this aberrancy. We suggest further trials be conducted in future for highlighting the role of miRNA in CAD, which may improve both the diagnostic and therapeutic approaches to stratifying CAD burden in the general population.

19.
J Pak Med Assoc ; 67(1): 97-99, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28065963

RESUMO

OBJECTIVE: To compare complications of cerebral angiography among patients with and without subarachnoid haemorrhage. METHODS: This retrospective study was conducted at the Aga Khan University Hospital, Karachi, and comprised records of patients undergoing inpatient therapeutic and diagnostic cerebral angiographies from 2001 to 2010. The patients were divided into subarachnoid and non-subarachnoid haemorrhage groups. During the study period no modifications were made to the operational protocol and all patients were subjected to the same procedure and prophylactic care. RESULTS: Of the 93 patients, 42(45.2%) were women and 51(54.8%) were men. The overall mean age was 45.27±16.15 years (range: 4-80 years). The comparison between the two groups regarding new onset of neurological deficit was statistically significant (p=0.001). However, the same comparison regarding drop in Glasgow Coma Scale was statistically not significant (p=0.073). CONCLUSIONS: The rate of neurological complications was higher in patients with subarachnoid haemorrhage.


Assuntos
Angiografia Cerebral/efeitos adversos , Angiografia Cerebral/estatística & dados numéricos , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
20.
Cureus ; 8(7): e693, 2016 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-27555991

RESUMO

Tuberous sclerosis complex (TSC) is a rare autosomal dominant genetic syndrome. The hallmark of the disease is multiple hamartomatous lesions in multiple organ systems. Common cardiac manifestations of TSC are rhabdomyomas, which are a benign tumor of striated muscle. In some patients with TSC, myocardial fatty foci (MFF) deposition has been described with or without the presence of rhabdomyomas. We present the case of a 24-year-old female with TSC and refractory seizures, who was evaluated with cardiac magnetic resonance (CMR) for an intracardiac right ventricular mass thought to be rhabdomyoma on echocardiography and for multiple areas of myocardial fatty deposition. Myocardial fatty deposition is a common finding in patients at cardiac imaging. In patients with TSC, it is critical that fatty deposits and lipomas are clearly distinguished from rhabdomyoma. CMR is an integral part of characterizing cardiac masses as it has superior soft tissue characterization and a wider field of view compared to echocardiography. A positive correlation has been shown between the number of MFF and the degree of extracardiac tuberous sclerosis (TS) manifestations suggesting that MFF may indicate more severe multiorgan disease in patients with TSC. Cardiac MR is superior to echocardiogram in evaluating and distinguishing intracardiac lipomas and fatty deposits from rhabdomyomas. Published studies have indicated that in patients with TSC, the presence of MFF correlates with the severity of multiorgan disease as was seen in our case.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...