Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 10(6): 1078-1086, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703164

RESUMO

BACKGROUND: In patients with persistent atrial fibrillation (PerAF), antiarrhythmic drugs (AADs) are considered a first-line rhythm-control strategy, whereas catheter ablation is a reasonable alternative. OBJECTIVES: This study sought to examine the prevalence, patient characteristics, and clinical outcomes of patients with PerAF who underwent catheter ablation as a first or second-line strategy. METHODS: This multicenter observational study included consecutive patients with PerAF who underwent first-time ablation between January 2020 and September 2021 in 9 medical centers in the United States. Patients were divided into those who underwent ablation as first-line therapy and those who had ablation as second-line therapy. Patient characteristics and clinical outcomes were compared between the groups. RESULTS: A total of 2,083 patients underwent first-time ablation for PerAF. Of these, 1,086 (52%) underwent ablation as a first-line rhythm-control treatment. Compared with patients treated with AADs as first-line therapy, these patients were predominantly male (72.6% vs 68.1%; P = 0.03), with a lower frequency of hypertension (64.0% vs 73.4%; P < 0.001) and heart failure (19.1% vs 30.5%; P < 0.001). During a mean follow-up of 325.9 ± 81.6 days, arrhythmia-free survival was similar between the groups (HR: 1.13; 95% CI: 0.92-1.41); however, patients in the second-line ablation strategy were more likely to continue receiving AAD therapy (41.5% vs 15.9%; P < 0.001). CONCLUSIONS: A first-line ablation strategy for PerAF is prevalent in the United States, particularly in men with fewer comorbidities. More data are needed to identify patients with PerAF who derive benefit from an early intervention strategy.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Masculino , Ablação por Cateter/estatística & dados numéricos , Feminino , Pessoa de Meia-Idade , Idoso , Antiarrítmicos/uso terapêutico , Resultado do Tratamento , Estados Unidos/epidemiologia
2.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

3.
JACC Clin Electrophysiol ; 7(8): 1013-1021, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33812831

RESUMO

OBJECTIVES: The objective of this clinical trial was to evaluate the safety and effectiveness of the TactiCath Contact Force Ablation Catheter, Sensor Enabled (TactiCath SE) (Abbott, Abbott Park, Illinois) for the treatment of drug-refractory, symptomatic paroxysmal atrial fibrillation (PAF). BACKGROUND: Catheter ablation of atrial fibrillation (AF) is an established therapy for the treatment of PAF. Ablation technology is evolving with the primary goals of improving efficacy and safety of the procedure. METHODS: This was a multicenter single-arm trial evaluating a novel ablation catheter for the treatment of PAF. A total of 156 subjects were enrolled at 19 sites in the United States, Europe, and Australia. The primary safety endpoint was the rate of device- or procedure-related serious adverse events occurring within 7 days. The primary effectiveness endpoint was acute success defined as pulmonary vein isolation at 30 min after ablation. Two descriptive endpoints were prospectively captured: 1) 1-year freedom from recurrence of symptomatic AF, atrial flutter (AFL), and atrial tachycardia (AT) lasting ≥30 s without a new or increased dose of Class I/III antiarrhythmic drugs; and 2) 1-year drug-free success defined by the absence of any recurrent AF/AFL/AT lasting ≥30 s without using Class I/III antiarrhythmic drugs. RESULTS: Primary safety events occurred in 4.7% of patients (95% confidence interval [CI]: 2.23% to 8.64%), and the procedure was acutely successful in 98.0% of patients (95% CI: 94.95% to 99.46%). According to Kaplan-Meier estimates at 1 year, 82.2% (95% CI: 74.7% to 87.6%) were free from symptomatic recurrence, and 1-year drug-free success was 68.2% (95% CI: 59.9% to 75.1%). CONCLUSIONS: The TactiCath™ Contact Force Ablation Catheter, Sensor Enabled™ is safe and effective for the treatment of paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/cirurgia , Recidiva
4.
Heart Rhythm ; 16(12): 1883-1889, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31255845

RESUMO

BACKGROUND: Catheter navigation and 3-dimensional (3D) cardiac mapping are essential components of minimally invasive electrophysiological procedures. OBJECTIVE: The purpose of this study was to develop a novel 3D mapping system (KODEX - EPD, EPD Solutions, Best, The Netherlands) that measures changing electric field gradients induced on intracardiac electrodes to enable catheter localization and real-time 3D cardiac mapping. METHODS: We first validated the accuracy of the system's measurement and localization capabilities by comparing known and KODEX - EPD-measured distances and locations at 12 anatomical landmarks in both the atria and ventricles of 4 swine. Next, in vivo images of 3D porcine cardiac anatomy generated by KODEX - EPD and widely used CARTO 3 system (Biosense Webster, Inc., Diamond Bar, CA) were compared with gold standard computed tomography images acquired from the same animals. Finally, 3D maps of atrial anatomy were created for 22 patients with paroxysmal atrial fibrillation (Dielectric Unravelling of Radiofrequency ABLation Effectiveness trial). RESULTS: First, the mean error between known and measured distances was 1.08 ± 0.11 mm (P < .01) and the overall standard deviation between known and measured locations in 12 areas of the porcine heart was 0.35 mm (P < .01). Second, an expert comparison of 3D image quality revealed that KODEX - EPD is noninferior to CARTO 3. Third, the system enabled 3D imaging of atrial anatomy in humans, provided real-time images of atrioventricular valves, and detected important anatomical variations in a subset of patients. CONCLUSION: The KODEX - EPD system is a novel 3D mapping system that accurately detects catheter location and can generate high-resolution images without the need for preacquired imaging, specialty catheters, or a point-by-point mapping procedure.


Assuntos
Fibrilação Atrial , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter , Cirurgia Assistida por Computador , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Precisão da Medição Dimensional , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Avaliação de Resultados em Cuidados de Saúde , Ajuste de Prótese/instrumentação , Ajuste de Prótese/métodos , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...