1.
JACC Clin Electrophysiol ; 7(3): 352-363, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33516712

RESUMO

OBJECTIVES: DIAMOND-AF (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation) was a prospective, multicenter, noninferiority, randomized trial that compared the safety and effectiveness of the DTA system versus those of a force-sensing RF ablation system (control) for the treatment of patients with drug-refractory, recurrent, symptomatic paroxysmal atrial fibrillation (AF). BACKGROUND: Irrigated radiofrequency (RF) ablation catheters lose tissue temperature acuity, which is vital in assessing lesion formation. DiamondTemp Ablation (DTA) was designed to re-establish accurate tissue temperature measurements during ablation. METHODS: A total of 482 patients with paroxysmal AF were randomized (239 DTA, 243 control) to undergo pulmonary vein isolation and were followed up at 23 sites. Patients were screened for disease progression, cardiac characteristics, and prior interventions. Primary endpoints were effectiveness (freedom from atrial arrhythmia recurrence) and safety (composite of procedure- and device-related serious adverse events). RESULTS: The primary safety event rate was 3.3% in the DTA group versus 6.6% in the control group (p < 0.001 vs. 6.5% noninferiority margin). Primary effectiveness was met in 79.1% of DTA subjects and 75.7% of control subjects (p < 0.001 vs. -12.5% noninferiority margin). Secondary endpoint analysis found that off-drug effectiveness favored DTA compared with the control (142 [59.4%] vs. 120 [49.4%], respectively; p = 0.03). Total RF time and individual RF ablation duration were significantly shorter with less saline infused through the DTA catheter (p < 0.001). Both arms saw clinically meaningful improvements in quality of life at 12 months. CONCLUSIONS: Safety and efficacy of the DTA system proved noninferior to force-sensing RF ablation in a paroxysmal AF population. Efficiencies were observed using DTA with shorter total RF times, individual RF ablation durations, and less saline infusion. (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation; NCT03334630).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Estudos Prospectivos , Qualidade de Vida , Temperatura , Resultado do Tratamento
2.
Am J Cardiol ; 111(8): 1165-8, 2013 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-23360767

RESUMO

The perioperative bleeding risk associated with therapeutic anticoagulation at cardiac implantable electronic device implantation has previously been demonstrated to vary by the specific anticoagulant used. Although uninterrupted anticoagulation with warfarin appears to be safe, heparin products have been shown to increase the risk of perioperative bleeding. However, the risk associated with cardiac implantable electronic device implantation with anticoagulation using dabigatran, a novel oral direct thrombin inhibitor, is not known. We performed a prospective observational study of patients receiving dabigatran for anticoagulation who underwent cardiac implantable electronic device implantation from June 2011 through May 2012. The study end points included thromboembolic and bleeding complications within 30 days of surgery. Major bleeding complications were defined as bleeding requiring surgical intervention, prolongation of hospitalization, and discontinuation of the anticoagulant or transfusion of blood products within 30 days of surgery. Minor bleeding complications included the development of a hematoma not requiring additional intervention. The thrombotic end points included stroke, transient ischemic attack, myocardial infarction, pulmonary embolism, and deep vein thrombosis. A total of 25 patients were identified for inclusion. During the index hospitalization, no thromboembolic or bleeding complications developed. No major bleeding complications occurred within 30 days of surgery. One minor bleeding event (4%) occurred within 30 days of surgery in 1 patient who was also receiving dual antiplatelet therapy. In conclusion, although no thromboembolic or major bleeding events were observed, additional studies are required to define the optimal antithrombotic management in the perioperative period.


Assuntos
Antitrombinas/efeitos adversos , Benzimidazóis/efeitos adversos , Desfibriladores Implantáveis , Marca-Passo Artificial , beta-Alanina/análogos & derivados , Idoso , Comorbidade , Dabigatrana , Feminino , Humanos , Masculino , Estudos Prospectivos , beta-Alanina/efeitos adversos