Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Phys ; 123(16)2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29725138

RESUMO

Cadmium telluride (CdTe) high purity, bulk, crystal ingots doped with phosphorus were grown by the vertical Bridgman melt growth technique to understand and improve dopant solubility and activation. Large net carrier densities have been reproducibly obtained from as-grown ingots, indicating successful incorporation of dopants into the lattice. However, net carrier density values are orders of magnitude lower than the solubility of P in CdTe as reported in literature, 1018/cm3 to 1019/cm3 [J. H. Greenberg, J. Cryst. Growth 161, 1-11 (1996) and R. B. Hall and H. H. Woodbury, J. Appl. Phys. 39(12), 5361-5365 (1968)], despite comparable starting charge dopant densities. Growth conditions, such as melt stoichiometry and post growth cooling, are shown to have significant impacts on dopant solubility. This study demonstrates that a significant portion of the dopant becomes incorporated into second phase defects as compounds of cadmium and phosphorous, such as cadmium phosphide, which inhibits dopant incorporation into the lattice and limits maximum attainable net carrier density in bulk crystals. Here, we present an extensive study on the characteristics of these second phase defects in relation to their composition and formation kinetics while providing a pathway to minimize their formation and enhance solubility.

2.
Anal Chem ; 90(11): 6587-6593, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29762013

RESUMO

Cr(VI) is a well-known human carcinogen with many water-soluble moieties. Its presence in both natural and man-made substances poses a risk to public health, especially when contamination of groundwater is possible. This has led the European Union and other jurisdictions to include Cr(VI) in restriction of hazardous substances regulations. However, for several important industrial and commercial purposes, analytical capability to characterize Cr(VI) is known to be insufficient for regulatory purposes. For example, advanced X-ray spectroscopies, particularly synchrotron-based X-ray absorption fine structure (XAFS) studies, have shown that species interconversion and under-extraction can be difficult to prevent in many existing liquid extraction protocols when applied to plastics, mining ores and tailings, and paint sludges. Here, we report that wavelength dispersive X-ray fluorescence spectroscopy taken at energy resolutions close to the theoretical limit imposed by the core-hole lifetime, generally called X-ray emission spectroscopy (XES) in the synchrotron community, can be used in the laboratory setting for noninvasive, analytical characterization of the Cr(VI)/Cr ratio in plastics. The selected samples have been part of ongoing efforts by standards development organizations to create improved Cr(VI) testing protocols, and the present work provides a direct proof-of-principle for the use of such extremely high-resolution laboratory WDXRF as an alternative to liquid extraction methods for regulatory compliance testing of Cr(VI) content. As a practical application of this work, we report a value for the Cr(VI) mass fraction of the new NIST Standard Reference Material 2859 Restricted Elements in Polyvinyl Chloride.


Assuntos
Cromo/análise , Laboratórios , Plásticos/química , Espectrometria por Raios X
3.
Cem Concr Compos ; 81: 109-121, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28785136

RESUMO

A common repair procedures applied to damaged concrete is to fill cracks with an organic polymer. This operation is performed to increase the service life of the concrete by removing a preferential pathway for the ingress of water, chlorides, and other deleterious species. To effectively fulfill its mission of preventing chloride ingress, the polymer must not only fully fill the macro-crack, but must also intrude the damage zone surrounding the crack perimeter. Here, the performance of two commonly employed crack fillers, one epoxy, and one methacrylate, are investigated using a combined experimental and computer modeling approach. Neutron tomography and microbeam X-ray fluorescence spectrometry (µXRF) measurements are employed on pre-cracked and chloride-exposed specimens to quantify the crack filling and chloride ingress limiting abilities, respectively, of the two polymers. A two-dimensional model of chloride transport is derived from a mass balance and solved by the finite element method. Crack images provided by µXRF are used to generate the input microstructure for the simulations. When chloride binding and a time-dependent mortar diffusivity are both included in the computer model, good agreement with the experimental results is obtained. Both crack fillers significantly reduce chloride ingress during the 21 d period of the present experiments; however, the epoxy itself contains approximately 4 % by mass chlorine. Leaching studies were performed assess the epoxy as a source of deleterious ions for initiating corrosion of the steel reinforcement in concrete structures.

4.
J AOAC Int ; 96(6): 1281-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24645505

RESUMO

Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.


Assuntos
Química Farmacêutica/normas , Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Vitaminas/análise , Carotenoides/análise , Química Farmacêutica/métodos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Comprimidos , Estados Unidos , Vitaminas/química
5.
Environ Sci Technol ; 45(24): 10492-500, 2011 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-22050765

RESUMO

Hexavalent chromium (Cr(VI)) occurrence in soils is generally determined using an extraction step to transfer it to the liquid phase where it is more easily detected and quantified. In this work, the performance of the most common extraction procedure (EPA Method 3060A) using NaOH-Na(2)CO(3) solutions is evaluated using X-ray absorption near edge structure spectroscopy (XANES), which enables the quantification of Cr(VI) directly in the solid state. Results obtained with both methods were compared for three solid samples with different matrices: a soil containing chromite ore processing residue (COPR), a loamy soil, and a paint sludge. Results showed that Cr(VI) contents determined by the two methods differ significantly, and that the EPA Method 3060A procedure underestimated the Cr(VI) content in all studied samples. The underestimation is particularly pronounced for COPR. Low extraction yield for EPA Method 3060A was found to be the main reason. The Cr(VI) present in COPR was found to be more concentrated in magnetic phases. This work provides new XANES analyses of SRM 2701 and its extraction residues for the purpose of benchmarking EPA 3060A performance.


Assuntos
Cromo/análise , Poluentes do Solo/análise , Solo/química , Fracionamento Químico/instrumentação , Fracionamento Químico/métodos , Cromo/química , Poluentes do Solo/química , Estados Unidos , United States Environmental Protection Agency , Espectroscopia por Absorção de Raios X
6.
Anal Bioanal Chem ; 396(8): 3041-50, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20186533

RESUMO

Two independent liquid chromatography inductively coupled plasma-mass spectrometry (LC/ICP-MS) methods for the separation of arsenic species in urine have been developed with quantification by standard additions. Seven arsenic species have been quantified in a new NIST frozen human urine Standard Reference Material (SRM) 2669 Arsenic Species in Frozen Human Urine, Levels 1 and 2. The species measured were: arsenite (As(III)), arsenate (As(V)), monomethylarsonate (MMA), dimethylarsinate (DMA), arsenobetaine (AB), arsenocholine (AC), and trimethylarsine oxide (TMAO). The purity of each arsenic standard used for quantification was measured as well as the arsenic species impurities determined in each standard. Analytical method limits of detection (L(D)) for the various species in both methods ranged from 0.2 to 0.8 microg L(-1) as arsenic. The results demonstrate that LC/ICP-MS is a sensitive, reproducible, and accurate technique for the determination of low-level arsenic species in urine. Measurements of the arsenic species 3 years after initial production of the SRM demonstrate the stability of the arsenic species in the urine reference material.


Assuntos
Arsênio/isolamento & purificação , Arsênio/urina , Arsenicais/isolamento & purificação , Arsenicais/urina , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Urina/química , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Humanos , Limite de Detecção , Espectrometria de Massas/instrumentação , Espectrometria de Massas/normas , Preservação Biológica , Reprodutibilidade dos Testes
7.
Anal Bioanal Chem ; 392(5): 995-1001, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18751686

RESUMO

Micro X-ray fluorescence (microXRF) has been used nondestructively to investigate elemental heterogeneity by constructing two-dimensional maps of elemental concentrations in reference materials. microXRF probes sample sizes well below the 100 mg mass usually recommended for reference materials by NIST. Multivariate methods of analysis, such as principal-component analysis (PCA), show promise in identifying whether "nugget" effects exist within a material, where an element is enriched in small, isolated areas of the sample. The PCA model is built based on data taken in one location and compared with each elemental map. This methodology is shown for several reference materials including SRM 2702 and SRM 2703 to show how PCA treatment can be used to identify which elements exhibit nugget effects within the sub-mg mass range. A method of calculating the minimum recommended mass for solid samples is suggested using PCA iteratively on X-ray maps from which adjacent data points have been averaged. This is repeated until the mass sampled in a map is indistinguishable from data taken at a single location, suggesting no nugget effects can be detected. For SRM 1577c, a mass as low as 370 microg can be used without measurable nugget effects.

8.
Anal Bioanal Chem ; 386(4): 1137-51, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17019587

RESUMO

NIST has developed an extensive collection of environmental SRMs, starting with fuel and biologically related materials in the late 1960s and now encompassing all sectors of environmental research. Advances in analytical methodology, including multi-element isotope-dilution mass spectrometry (IDMS) and expanded instrumental neutron-activation analysis (INAA) capabilities, enable value assignment based on fewer but better-characterized independent analytical techniques. The special advantages of IDMS for determination of S and Hg and for multi-element characterization of small-sample air particulate matter (SRM 2783) by IDMS and INAA are emphasized. Developments in materials production include the issuance of fresh-frozen biological materials and of jet-milled natural-matrix materials with improved homogeneity, including highly homogeneous air particulate matter and sediment SRMs for small-sample analytical techniques.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Compostos Inorgânicos/análise , Animais , Tamanho da Partícula , Padrões de Referência
9.
Anal Bioanal Chem ; 380(5-6): 843-52, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15551075

RESUMO

The measurement of water in lubricating oils is important because water accelerates the corrosion of metal parts and bearings in motors. Some of the additives added to lubricating oils to improve their performance react with the Karl Fischer reagent (KFR) causing a positive bias in the water measurement. A new oven evaporation technique for measuring water in oils has been developed that is automated, requires less sample handling, is easily calibrated, and is capable of measuring relatively small mass fractions of water (> or =50 mg/kg sample). A series of motor oils was analyzed with the standard KFR, a reagent that detects interfering substances that reduce iodine, and the aldehyde-ketone reagent that does not detect substances that react with methanol and form water. The oil samples were heated to 107 degrees C and then reheated to 160 degrees C. At both temperatures, material was measured by both KFRs, but only zinc dithiophosphate released sulfur compounds that would react with the reagent that detects interfering substances. Mass fractions of between 20 and 70% of the volatile material released at either temperature were measured with the standard KFR but not with the aldehyde-ketone reagent. These results demonstrate that there are a number of sources of positive bias in the measurement of water in motor oils and that the standard KFR cannot be used to measure water in motor oils and motor oil additives. These results also indicate that some of the material reacts with methanol to form water. Finally, these results suggest that some of the material that is volatile at 160 degrees C and not at 107 degrees C may be water that is physically occluded or may be substances that react with diethyleneglycol monomethylether to produce water.


Assuntos
Temperatura Alta , Óleo Mineral/análise , Projetos de Pesquisa , Água/análise , Lubrificação , Fatores de Tempo , Volatilização
10.
Anal Bioanal Chem ; 380(3): 556-62, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15365678

RESUMO

Using an automated oven evaporation technique combined with the coulometric Karl Fischer method, the mass fraction of water has been measured in cement, coal, and refined oil samples. The accuracy of this method was established by using SRM 2890, water-saturated 1-octanol that was added to white oil. The samples were analyzed for total reactive Karl Fischer reagent (KFR) material, for interfering materials, and for material that does not react with the aldehyde-ketone KFR. All of the samples yielded volatile material that reacted with the standard KFR. None of the samples contained significant masses of material that reacted with iodine. The cement and coal SRMs contained no material that reacted with methanol and very little material that did not volatilize at 107 degrees C. The refined oils contained some material that was volatile at 107 degrees C and some at 160 degrees C. However, none of this material reacted with the aldehyde-ketone reagent. These results show that the material in the solid samples is water and that the material in the refined oils is a material other than water which reacts with methanol to form water.

11.
J Agric Food Chem ; 50(24): 7069-75, 2002 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-12428961

RESUMO

Standard Reference Material (SRM) Baking Chocolate was recently issued, and the process used for value assignment of nutrient concentrations is reported herein. SRM 2384 is intended for use as a primary control material for assigning values to in-house control materials and for validation of analytical methods for the measurement of fatty acids, proximates, vitamins, and elements in chocolate and similar high-fat matrices. The Certificate of Analysis for SRM 2384 provides assigned values for concentrations of fatty acids, proximates, vitamins, elements, and total dietary fiber, for which product labeling is required by the Nutrition Labeling and Education Act of 1990, as well as for catechins, caffeine, theobromine, and theophylline. These assigned values were based on measurements by NIST and/or collaborating laboratories.


Assuntos
Cacau/química , Rotulagem de Alimentos , Valor Nutritivo , Cafeína/análise , Cálcio/análise , Catequina/análise , Gorduras na Dieta/análise , Fibras na Dieta/análise , Ingestão de Energia , Ácidos Graxos/análise , Ferro/análise , Controle de Qualidade , Padrões de Referência , Sódio/análise , Teobromina/análise , Vitaminas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...