Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Cardiothorac Vasc Anesth ; 38(3): 745-754, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38172029

RESUMO

OBJECTIVES: Combined heart-liver transplantation (CHLT) is becoming increasingly frequent as a maturing population of patients with Fontan-palliated congenital heart disease develop advanced liver fibrosis or cirrhosis. The authors present their experience with CHLT for congenital and noncongenital indications, and identify characteristics associated with poor outcomes that may guide intervention in high-risk patients. DESIGN: This was a single-center retrospective cohort study. SETTING: This study was conducted at Vanderbilt University Medical Center in Nashville, Tennessee. PARTICIPANTS: The study included 16 consecutive adult recipients of CHLT at the authors' institution between April 2017 and February 2022. INTERVENTIONS: Eleven patients underwent transplantation for Fontan indications, and 5 were transplanted for non-Fontan indications. MEASUREMENTS AND MAIN RESULTS: Compared with non-Fontan patients, Fontan recipients had longer cardiopulmonary bypass duration (199 v 119 minutes, p =m0.002), operative times (786 v 599 minutes, p = 0.01), and larger blood product transfusions (15.4 v 6.3 L, p = 0.18). Six of 16 patients required extracorporeal membrane oxygenation (ECMO), of whom 4 were Fontan patients who subsequently died. Patients who required ECMO had lower 5-hour lactate clearance (0.0 v 3.5 mmol/L, p = 0.001), higher number of vasoactive infusions, lower pulmonary artery pulsatility indices (0.58 v 1.77, p = 0.03), and higher peak inspiratory pressures (28.0 v 18.5 mmHg, p = 0.01) after liver reperfusion. CONCLUSIONS: Combined heart-liver transplantation in patients with Fontan-associated end-organ disease is particularly challenging and associated with higher recipient morbidity compared with non-Fontan-related CHLT. Early hemodynamic intervention for signs of ventricular dysfunction may improve outcomes in this growing high-risk population.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Transplante de Coração , Transplante de Fígado , Adulto , Humanos , Estudos Retrospectivos , Cardiopatias Congênitas/cirurgia , Fígado/cirurgia
3.
J Clin Anesth ; 86: 111056, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36682226

RESUMO

Alpha Gal Syndrome (AGS) is an emerging immune response to mammalian products (MP) containing the oligosaccharide galactose-α-1,3 galactose (α-Gal) which includes meats and inactive ingredients in certain medications. This becomes clinically important in the perioperative realm as MPs are commonly found in the operating room, and pre- and post-operative settings, and can trigger responses as severe as anaphylaxis. In this review, authors discuss the epidemiology, diagnosis and treatment of AGS reactions. Additionally, strategies are explored in order to screen and prevent exposure to MP with a multidisciplinary approach. While this emerging allergy is still not fully understood, it is of paramount importance that all anesthesia providers recognize the implications of MP exposure in AGS patients and ultimately prevent harm in this highly vulnerable population.


Assuntos
Anafilaxia , Hipersensibilidade Alimentar , Animais , Humanos , Galactose , Hipersensibilidade Alimentar/epidemiologia , Anafilaxia/diagnóstico , Anafilaxia/epidemiologia , Anafilaxia/etiologia , Carne/efeitos adversos , Mamíferos
6.
Semin Cardiothorac Vasc Anesth ; 26(4): 266-273, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35617152

RESUMO

Background. A retrospective case-control study was conducted to assess the feasibility of erector spinae plane (ESP) block as part of a multimodal enhanced recovery program for patients undergoing minimally invasive mitral valve replacement surgery. Methods. This retrospective analysis was conducted at a single center between January and August 2019. 61 patients were included; 23 received ESP and 38 did not. Erector spinae catheters (ESCs) were placed preoperatively, using a loading dose of 30 mL .5% ropivacaine, followed by an infusion of .2% ropivacaine at 10 mL/h throughout the study period. Primary outcome was 48-hour opioid consumption. Secondary outcomes included intraoperative morphine equivalents, extubation within 24 hours, reintubation, ICU length of stay and hospital length of stay and 30-day mortality. Results. Median [inter-quartile range] of the postoperative morphine milligram equivalents (MMEs) in the first 48 hours was 70[45-121] MMEs in the ESC) group, and 109[70-148] MMEs in the no ESC group (P-value = .16). No significant difference was observed in intraoperative morphine equivalents, extubation within 24 hours or ICU length of stay. The ESC group had shorter hospital length of stay (6.0 vs 7.0 days, P-value = .043). Conclusion. This study found a statistically insignificant, though potentially clinically significant reduction in postoperative opioid consumption. A reduced hospital length of stay as well as an acceptable safety profile was also observed in the ESC group. An adequately powered, prospective trial is warranted to accurately assess the potential role for ESP catheters for patients undergoing minimally invasive mitral valve surgery.


Assuntos
Analgesia , Bloqueio Nervoso , Humanos , Bloqueio Nervoso/métodos , Analgésicos Opioides , Dor Pós-Operatória/prevenção & controle , Anestésicos Locais , Estudos Retrospectivos , Estudos Prospectivos , Valva Mitral/cirurgia , Ropivacaina , Estudos de Casos e Controles , Analgesia/métodos , Morfina , Catéteres
7.
J Cardiothorac Vasc Anesth ; 36(7): 2046-2050, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34272116

RESUMO

Pulmonary venous thrombosis (PVT) is a rare but potentially devastating disease state with a largely unknown incidence. The most common etiologies of PVT are secondary to complications of lung surgery, malignancy, catheter ablation for atrial fibrillation, and idiopathic causes. Diagnosis can be challenging because presenting symptoms often are vague and nonspecific, or even asymptomatic, and traditional diagnostic modalities, such as chest radiography and arterial phase computed tomography scans, are poor techniques for diagnosis. The authors present a case of a patient presenting for pulmonary thromboendarterectomy for a presumed diagnosis of chronic thromboembolic pulmonary hypertension who was found incidentally to have a PVT, on intraoperative transesophageal echocardiography. Due to significant thrombus burden, the new finding of PVT, and known association of PVT and malignancy, a biopsy of mediastinal lymph nodes was obtained, which revealed metastatic cervical carcinoma. The pulmonary endarterectomy procedure was aborted.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Trombose Venosa , Endarterectomia/métodos , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Pulmão , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/cirurgia , Trombose Venosa/complicações , Trombose Venosa/diagnóstico por imagem
8.
J Cardiothorac Vasc Anesth ; 35(9): 2775-2783, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33773891

RESUMO

The electrophysiology laboratory facilitates complex procedures on patients, many of whom have advanced disease processes and extensive comorbidities. Historically, nurses administered sedation as required, but in recent years a shift to anesthesiologist-led sedation has been promoted for patient safety and advanced therapeutic considerations. Uncertainty remains, however, regarding whether the electrophysiology laboratory is best staffed with general or cardiothoracic anesthesiologists. In this article, the authors discuss the anesthetic considerations of some commonly performed electrophysiology and structural cardiac procedures and the pros and cons of staffing with general or cardiothoracic anesthesiologists.


Assuntos
Anestesia , Anestésicos , Eletrofisiologia , Humanos , Laboratórios , Recursos Humanos
9.
Semin Cardiothorac Vasc Anesth ; 24(4): 364-368, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32746732

RESUMO

Noonan syndrome is a relatively common genetic disorder and the second most common cause of congenital heart disease after trisomy 21. The spectrum of cardiac anomalies in Noonan syndrome typically involves pulmonary valve stenosis occasionally in conjunction with hypertrophic cardiomyopathy. Mitral valve involvement is a rare finding in Noonan syndrome and is most commonly associated with either mitral valve prolapse or abnormal valvular insertion causing left ventricular outflow tract obstruction. Patients with Noonan syndrome typically have preserved fertility and, given the success of cardiac surgery and medical management of heart failure in this population, are beginning to present more commonly as parturients in adulthood. Maternal physiologic changes during pregnancy introduce an added complexity to hemodynamic management and anesthetic considerations during labor and delivery. In this article, we present a case of a patient with Noonan syndrome with severe mitral stenosis, pulmonary valve insufficiency, and severe restrictive and obstructive pulmonary disease who presented preterm for delivery due to increased dyspnea at rest. Here we review the pathophysiology behind Noonan syndrome and peripartum management strategies in a patient with severe combined cardiac and pulmonary disease.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Pneumopatias Obstrutivas/complicações , Estenose da Valva Mitral/complicações , Síndrome de Noonan/complicações , Síndrome de Noonan/fisiopatologia , Complicações na Gravidez/fisiopatologia , Insuficiência da Valva Pulmonar/complicações , Adulto , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Cesárea , Dispneia/complicações , Dispneia/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Pneumopatias Obstrutivas/diagnóstico por imagem , Pneumopatias Obstrutivas/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Gravidez , Nascimento Prematuro , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Ultrassonografia/métodos
12.
J Cardiovasc Electrophysiol ; 31(10): 2762-2764, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33462878

RESUMO

Patients with cardiac implantable electronic devices (CIED) and implantable cardioverter-defibrillator (ICD) devices frequently present for surgical procedures. If electrocautery is used, careful planning is needed to avoid inappropriate device function or device damage. Published consensus statements suggest that if the surgery is below the umbilicus, interference is typically minimal, and therefore it is not recommended to reprogram or disable the CIED. When these guidelines were published, full-body return electrodes were not commonly used in clinical practice, and therefore were not addressed in the recommendations. A 76-year-old male with a single chamber ICD underwent bladder surgery under general anesthesia. Monopolar cautery was used with a full-body return electrode. The patient had undergone a similar procedure multiple times prior utilizing a traditional thigh adhesive return electrode without any inappropriate ICD discharges. During the procedure, the patient's movement was noted with electrocautery use which was suspected to be an inappropriate discharge of his ICD. Device interrogation was performed confirming two antitachycardia pacing therapies and four defibrillations due to interference from the electrocautery. This case examines inappropriate ICD discharge related to interference from electrocautery when utilizing a full-body return electrode, despite a subumbilical location of surgery. Current consensus statement guidelines do not recommend device reprogramming or magnet used when surgery is below the umbilicus, however, these full-body return electrodes were not routinely used when these guidelines were published. Based on these results, the authors avoid full-body return electrodes in patients with CIEDs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Neoplasias da Bexiga Urinária , Idoso , Eletrocoagulação/efeitos adversos , Humanos , Masculino , Alta do Paciente , Neoplasias da Bexiga Urinária/cirurgia
13.
Anesth Analg ; 129(1): 92-98, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30973383

RESUMO

Minutes count in the operating room when it comes to treatment guidance and therapies. On a daily basis, anesthesiologists make hundreds of decisions, some based on laboratory results, when guiding patient therapies. When time is crucial, point-of-care testing is often utilized for expediency. However, point-of-care testing has its limitations. Providers should be aware of the limitations, including the potential for error in results-errors that could lead to improper treatment and possible patient harm. This article outlines the technical aspects and summarizes pitfalls in accuracy for 2 of the most commonly utilized point-of-care testing devices: glucose meters and hemoglobin meters.


Assuntos
Análise Química do Sangue/instrumentação , Glicemia/metabolismo , Hemoglobinas/metabolismo , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Biomarcadores/sangue , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Fluxo de Trabalho
14.
Trials ; 18(1): 295, 2017 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-28651648

RESUMO

BACKGROUND: Anesthesiologists administer excess supplemental oxygen (hyper-oxygenation) to patients during surgery to avoid hypoxia. Hyper-oxygenation, however, may increase the generation of reactive oxygen species and cause oxidative damage. In cardiac surgery, increased oxidative damage has been associated with postoperative kidney and brain injury. We hypothesize that maintenance of normoxia during cardiac surgery (physiologic oxygenation) decreases kidney injury and oxidative damage compared to hyper-oxygenation. METHODS/DESIGN: The Risk of Oxygen during Cardiac Surgery (ROCS) trial will randomly assign 200 cardiac surgery patients to receive physiologic oxygenation, defined as the lowest fraction of inspired oxygen (FIO2) necessary to maintain an arterial hemoglobin saturation of 95 to 97%, or hyper-oxygenation (FIO2 = 1.0) during surgery. The primary clinical endpoint is serum creatinine change from baseline to postoperative day 2, and the primary mechanism endpoint is change in plasma concentrations of F2-isoprostanes and isofurans. Secondary endpoints include superoxide production, clinical delirium, myocardial injury, and length of stay. An endothelial function substudy will examine the effects of oxygen treatment and oxidative stress on endothelial function, measured using flow mediated dilation, peripheral arterial tonometry, and wire tension myography of epicardial fat arterioles. DISCUSSION: The ROCS trial will test the hypothesis that intraoperative physiologic oxygenation decreases oxidative damage and organ injury compared to hyper-oxygenation in patients undergoing cardiac surgery. TRIAL REGISTRATION: ClinicalTrials.gov, ID: NCT02361944 . Registered on the 30th of January 2015.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Hiperóxia/etiologia , Oxigenoterapia/efeitos adversos , Biomarcadores/sangue , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Protocolos Clínicos , Creatinina/sangue , F2-Isoprostanos/sangue , Furanos/sangue , Humanos , Hiperóxia/sangue , Hiperóxia/diagnóstico , Hiperóxia/fisiopatologia , Cuidados Intraoperatórios , Estresse Oxidativo/efeitos dos fármacos , Oxigênio/sangue , Oxiemoglobinas/metabolismo , Projetos de Pesquisa , Respiração Artificial , Fatores de Risco , Tennessee , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...