Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 313: 124148, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38492463

RESUMO

Oleogel represents a promising healthier alternative to act as a substitute for conventional fat in various food products. Oil selection is a crucial factor in determining the technological properties and applications of oleogels due to their distinct fatty acid composition, molecular weight, and thermal properties, as well as the presence of antioxidants and oxidative stability. Hence, the relevance of monitoring oleogel properties by non-destructive, eco-friendly, portable, fast, and effective techniques is a relevant task and constitutes an advance in the evaluation of oleogels quality. Thus, the present study aims to classify oleogels rapidly and reliably, without the use of chemicals, comparing two handheld near infrared (NIR) spectrometers and one portable Raman device. Furthermore, two different multivariate methods are compared for oleogel classification according to oil type. Three types of oleogels were prepared, containing 95 % oil (sunflower, soy, olive) and 5 % beeswax as a structuring agent, melted at 90 °C. Polarized light microscopy (PLM) images were acquired, and fatty acid composition, peroxide index and free fatty acid content were determined using official methods. A total of 240 oleogel and 92 oil spectra were obtained for each instrument. After spectra pretreatment, Principal Component Analysis (PCA) was performed, and two classification methods were investigated. The Data Driven - Soft Independent Modelling of Class Analogy (DD-SIMCA) and Partial Least Squares Discriminant Analysis (PLS-DA) models demonstrated 95 % to 100 % of accuracy for the external test set. In conclusion, the use of vibrational spectroscopy using handheld and portable instruments in tandem with chemometrics showed to be an efficient alternative for classifying oils and oleogels and could be extended to other food samples. Although the classification of vegetable oils by NIR is widely used and known, this work proposes the classification of different types of oil in oleogel matrices, which has not yet been explored in the literature.


Assuntos
Quimiometria , Óleos de Plantas , Ácidos Graxos/química , Análise Espectral , Compostos Orgânicos
2.
Molecules ; 28(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38067622

RESUMO

The following investigations describe the potential of handheld NIR spectroscopy and Raman imaging measurements for the identification and authentication of food products. On the one hand, during the last decade, handheld NIR spectroscopy has made the greatest progress among vibrational spectroscopic methods in terms of miniaturization and price/performance ratio, and on the other hand, the Raman spectroscopic imaging method can achieve the best lateral resolution when examining the heterogeneous composition of samples. The utilization of both methods is further enhanced via the combination with chemometric evaluation methods with respect to the detection, identification, and discrimination of illegal counterfeiting of food products. To demonstrate the solution to practical problems with these two spectroscopic techniques, the results of our recent investigations obtained for various industrial processes and customer-relevant product examples have been discussed in this article. Specifically, the monitoring of food extraction processes (e.g., ethanol extraction of clove and water extraction of wolfberry) and the identification of food quality (e.g., differentiation of cocoa nibs and cocoa beans) via handheld NIR spectroscopy, and the detection and quantification of adulterations in powdered dairy products via Raman imaging were outlined in some detail. Although the present work only demonstrates exemplary product and process examples, the applications provide a balanced overview of materials with different physical properties and manufacturing processes in order to be able to derive modified applications for other products or production processes.


Assuntos
Cacau , Espectroscopia de Luz Próxima ao Infravermelho , Cacau/química , Alimentos , Controle de Qualidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise Espectral Raman/métodos
3.
Anal Chem ; 95(17): 6888-6893, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37070825

RESUMO

For successful soil remediation and hydrocarbon exploration operations, determining the total petroleum hydrocarbon (TPH) content of soils is an indispensable process step. This paper reports on the performance of a handheld Fourier transform near-infrared (FT-NIR) spectrometer for rapid and quantitative determination of TPH content of soils from two different sites by diffuse reflection measurements. For rapid decisions for exploration work or environmental site assessment projects, a quick─preferably on-site─determination of TPH content is valuable. Diffuse reflection NIR spectra were recorded from soil samples of two different sites with TPH reference values ranging from 350 to 30,000 ppm, as determined by capillary gas chromatography and flame ionization detection with hydrocarbon fingerprinting C1-C44. However, this paper not only addresses the development of site-specific partial-least squares (PLS) calibrations but also demonstrates the locally-weighted PLS (LW-PLS) technique, which can be used to develop global, site-independent PLS calibrations without significant penalty in calibration performance. As a first step, the diffuse reflection spectra were used to develop conservative, site-specific PLS calibration models with root-mean-square calibration/cross-validation errors (RMSEC/RMSECV) of 1043/1106 and 741/785 ppm TPH, respectively, and the average absolute prediction errors for samples not contained in the calibration set were 451 and 293 ppm for the two sites, respectively. In a further step, significant degradation of the RMSE values of a conservative PLS model based on the NIR spectra of both sites was then compared to the application of the LW-PLS method, with only a slight loss of the prediction accuracy relative to the site-independent models. This study confirms the ability of next-generation portable FT-NIR spectrometers to predict low TPH levels in various soil types through both─soil-specific and site-independent─calibrations, giving these spectrometers the potential to become rapid screening tools in the field.

4.
Front Plant Sci ; 10: 1548, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31827484

RESUMO

Recently, miniaturization of Raman, mid-infrared (MIR) and near-infrared (NIR) spectrometers have made substantial progress, and marketing companies predict this segment of instrumentation a significant growth rate within the next few years. This increase will be based on a more frequent implementation for industrial quality and process control and a broader adoption of spectrometers for in-the-field testing, on-site measurements, and every-day-life consumer applications. The reduction in size, however, must not lead to compromises in measurement performance and the hand-held instrumentation will only have a real impact if spectra of comparable quality to laboratory spectrometers can be obtained. The present communication will, on the one hand, explain the instrumental reasons why NIR spectroscopy is presently the most advanced technique regarding miniaturization and on the other hand, it will emphasize the impact of NIR spectroscopy for plant analysis by discussing in some detail a qualitative and a quantitative application example.

5.
Molecules ; 24(19)2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31581527

RESUMO

The band shapes and band positions of near-infrared (NIR) and Raman spectra change depending on the concentrations of specific chemical functionalities in a multicomponent system. To elucidate these effects in more detail and clarify their impact on the analytical measurement techniques and evaluation procedures, NIR transmission spectra and Raman spectra of two organic liquid three-component systems with variable compositions were analyzed by two different multivariate calibration procedures, partial least squares (PLS) and classical least-squares (CLS) regression. Furthermore, the effect of applying different concentration units (volume percent (%V) and weight percent (%W) on the performance of the two calibration procedures have been tested. While the mixtures of benzene/cyclohexane/ethylbenzene (system 1) can be regarded as a blended system with comparatively low molecular interactions, hydrogen bonding plays a dominant role in the blends of ethyl acetate/1-heptanol/1,4-dioxane (system 2). Whereas system 1 yielded equally good calibrations by PLS and CLS regression, for system 2 acceptable results were only obtained by PLS regression. Additionally, for both sample systems, Raman spectra generally led to lower calibration performance than NIR spectra. Finally, volume and weight percent concentration units yielded comparable results for both chemometric evaluation procedures.


Assuntos
Hidrocarbonetos Cíclicos/isolamento & purificação , Derivados de Benzeno/isolamento & purificação , Calibragem , Cicloexanos/isolamento & purificação , Ligação de Hidrogênio , Análise dos Mínimos Quadrados , Peso Molecular , Espectroscopia de Luz Próxima ao Infravermelho , Análise Espectral Raman
6.
Molecules ; 24(11)2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31141878

RESUMO

Nowadays, near infrared (NIR) spectroscopy has experienced a rapid progress in miniaturization (instruments < 100 g are presently available), and the price for handheld systems has reached the < $500 level for high lot sizes. Thus, the stage is set for NIR spectroscopy to become the technique of choice for food and beverage testing, not only in industry but also as a consumer application. However, contrary to the (in our opinion) exaggerated claims of some direct-to-consumer companies regarding the performance of their "food scanners" with "cloud evaluation of big data", the present publication will demonstrate realistic analytical data derived from the development of partial least squares (PLS) calibration models for six different nutritional parameters (energy, protein, fat, carbohydrates, sugar, and fiber) based on the NIR spectra of a broad range of different pasta/sauce blends recorded with a handheld instrument. The prediction performance of the PLS calibration models for the individual parameters was double-checked by cross-validation (CV) and test-set validation. The results obtained suggest that in the near future consumers will be able to predict the nutritional parameters of their meals by using handheld NIR spectroscopy under every-day life conditions.


Assuntos
Alimentos , Avaliação Nutricional , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Calibragem , Análise dos Mínimos Quadrados
7.
J Pharm Biomed Anal ; 160: 179-186, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-30096648

RESUMO

Notwithstanding the first developments of miniaturized vibrational spectrometers more than a decade ago, only recently real handheld near-infrared (NIR) spectrometers (<200 g) became commercially available at significantly reduced costs compared to other portable systems. While on the one hand this development was driven by the consumer request for every-day-life applications by non-experts, on the manufacturer side it was supported by the availability and potential of new technologies such as micro-electromechanical systems (MEMS). In the present communication calibration spectra of a solid pharmaceutical formulation consisting of two excipients and three active ingredients, acetylsalicylic acid (ASA), ascorbic acid (ASC) and caffeine (CAF), have been measured with four handheld NIR spectrometers based on different monochromator principles and have subsequently been used to develop partial least squares (PLS) models for the quantitative determination of the active ingredients. Taking into account the instrumental and spectral peculiarities of the four instruments and the three analytes, respectively, the detailed analysis of the calibration parameters and the prediction accuracy for a test sample set then allowed to compare the performance of the different spectrometers for the analytical problem under investigation.


Assuntos
Composição de Medicamentos/estatística & dados numéricos , Estudos de Avaliação como Assunto , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Ácido Ascórbico/análise , Aspirina/análise , Cafeína/análise , Calibragem , Espectroscopia de Luz Próxima ao Infravermelho/métodos
8.
Appl Spectrosc ; 72(9): 1362-1370, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29855195

RESUMO

For sustainable utilization of raw materials and environmental protection, the recycling of the most common polymers-polyethylene (PE), polypropylene (PP), polyethylene terephthalate (PET), polyvinyl chloride (PVC), and polystyrene (PS)-is an extremely important issue. In the present communication, the discrimination performance of the above polymer commodities based on their near-infrared (NIR) spectra measured with four real handheld (<200 g) spectrometers based on different monochromator principles were investigated. From a total of 43 polymer samples, the diffuse reflection spectra were measured with the handheld instruments. After the original spectra were pretreated by second derivative and standard normal variate (SNV), principal component analysis (PCA) was applied and unknown samples were tested by soft independent modeling of class analogies (SIMCA). The results show that the five polymer commodities cluster in the score plots of their first three principal components (PCs) and, furthermore, samples in calibration and test sets can be correctly identified by SICMA. Thus, it was concluded that on the basis of the NIR spectra measured with the handheld spectrometers the SIMCA analysis provides a suitable analytical tool for the correct assignment of the type of polymer. Because the mean distance between clusters in the score plot reflects the discrimination capability for each polymer pair the variation of this parameter for the spectra measured with the different handheld spectrometers was used to rank the identification performance of the five polymer commodities.


Assuntos
Polímeros , Espectroscopia de Luz Próxima ao Infravermelho , Calibragem , Polímeros/análise , Polímeros/química , Polímeros/classificação , Análise de Componente Principal , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Espectroscopia de Luz Próxima ao Infravermelho/normas
9.
Spectrochim Acta A Mol Biomol Spectrosc ; 188: 478-482, 2018 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-28759848

RESUMO

In the present communication the potential of 2DCOS analysis and the spin-off technique perturbation-correlation moving window 2D (PCMW2D) analysis is illustrated with reference to spectroscopic changes observed in a data set recorded by in-line fiber-coupled FT-IR spectroscopy in the attenuated total reflection (ATR) mode during a polyurethane solution polymerization at different temperatures. In view of the chemical functionalities involved, hydrogen bonding plays an important role in this polymerization reaction. Based on the 2DCOS and PCMW2D analysis, the sequence of hydrogen bonding changes accompanying the progress of polymerization and precipitation of solid polymer can be determined. Complementary to the kinetic data derived from the original variable-temperature spectra in a previous publication the results provide a more detailed picture of the investigated solution polymerization.

10.
Anal Bioanal Chem ; 409(3): 833-839, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27376357

RESUMO

Polyurethanes are a polymer class with large property diversity. However, despite their extreme technical importance, only few research data regarding the on-line analysis and the derivation of kinetic polymerization data are available in the literature. The present work focuses on the in-line monitoring of the solution polymerization of 4,4'-diphenylmethanediisocyanate and 1,4-butanediol by fiber-coupled FT-IR spectroscopy in the attenuated total reflection (ATR) mode at variable temperatures and the interpretation of the spectral changes as a function of polymerization progress. Furthermore, the activation energy of the solution polymerization will be derived from the kinetic data and experimental issues of the ATR in-line measurement mode will be addressed.

11.
Appl Spectrosc ; 70(7): 1202-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27287846

RESUMO

The main objective of this communication is to compare the performance of a miniaturized handheld near-infrared (NIR) spectrometer with a benchtop Fourier transform near-infrared (FT-NIR) spectrometer. Generally, NIR spectroscopy is an extremely powerful analytical tool to study hydrogen-bonding changes of amide functionalities in solid and liquid materials and therefore variable temperature NIR measurements of polyamide II (PAII) have been selected as a case study. The information content of the measurement data has been further enhanced by exploiting the potential of two-dimensional correlation spectroscopy (2D-COS) and the perturbation correlation moving window two-dimensional (PCMW2D) evaluation technique. The data provide valuable insights not only into the changes of the hydrogen-bonding structure and the recrystallization of the hydrocarbon segments of the investigated PAII but also in their sequential order. Furthermore, it has been demonstrated that the 2D-COS and PCMW2D results derived from the spectra measured with the miniaturized NIR instrument are equivalent to the information extracted from the data obtained with the high-performance FT-NIR instrument.

12.
Appl Spectrosc ; 70(5): 852-60, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27170780

RESUMO

The aim of this contribution is to demonstrate the transfer of spectra that have been measured on two different laboratory Fourier transform near-infrared (FT-NIR) spectrometers to the format of a handheld instrument by measuring only a few samples with both spectrometer types. Thus, despite the extreme differences in spectral range and resolution, spectral data sets that have been collected and quantitative as well as qualitative calibrations that have been developed thereof, respectively, over a long period on a laboratory instrument can be conveniently transferred to the handheld system. Thus, the necessity to prepare completely new calibration samples and the effort required to develop calibration models when changing hardware platforms is minimized. The enabling procedure is based on piecewise direct standardization (PDS) and will be described for the data sets of a quantitative and a qualitative application case study. For this purpose the spectra measured on the FT-NIR laboratory spectrometers were used as "master" data and transferred to the "target" format of the handheld instrument. The quantitative test study refers to transmission spectra of three-component liquid solvent mixtures whereas the qualitative application example encompasses diffuse reflection spectra of six different current polymers. To prove the performance of the transfer procedure for quantitative applications, partial least squares (PLS-1) calibrations were developed for the individual components of the solvent mixtures with spectra transferred from the master to the target instrument and the cross-validation parameters were compared with the corresponding parameters obtained for spectra measured on the master and target instruments, respectively. To test the retention of the discrimination ability of the transferred polymer spectra sets principal component analyses (PCAs) were applied exemplarily for three of the six investigated polymers and their identification was demonstrated by Mahalanobis distance plots for all polymers.

13.
Appl Spectrosc ; 70(4): 635-44, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26928223

RESUMO

The near-infrared transmission spectra of two organic liquid three-component systems of variable compositions were investigated in detail. To evaluate the interaction of the different components in the two systems the experimental spectra of the pure components were compared to mathematically constructed "pure component" spectra. Though usually the correlation coefficient (CC) and Manhattan distance (MD) are used to measure the similarity of spectra, in the present investigations principal component analysis (PCA) was found to be a more effective tool to investigate the difference between these spectra and derive parameters characterizing the interaction between the different components. Thus, PC scores for the two types of spectra established some distinct patterns which clearly expressed their differences. For a three-dimensional coordinate system of selected principal components, the Euclidean distances between the mathematically constructed and the experimental spectra of the pure components were calculated. Finally, the mean values of the distances for each component provided indices to rank the interaction of the components in the mixtures. Thus, the results offer a convenient approach that can quantitatively evaluate the molecular interactions of the individual components in organic liquid mixtures by various spectroscopies.

14.
Appl Spectrosc ; 68(10): 249A-250A, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25371925
15.
Appl Spectrosc ; 68(5): 603-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25014605

RESUMO

In the present publication, the deuterium/hydrogen (D/H) exchange of liquid D2O exposed to water vapor of the surrounding atmosphere has been studied by variable-temperature Fourier transform near-infrared (FT-NIR) imaging spectroscopy. Apart from the visualization of the exchange process in the time-resolved FT-NIR images, kinetic parameters and the activation energy for this D/H exchange reaction have been derived from the Arrhenius plot of the variable-temperature spectroscopic data.


Assuntos
Óxido de Deutério/química , Deutério/química , Hidrogênio/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Fenômenos Químicos , Cinética , Temperatura , Água/química
16.
Appl Spectrosc ; 67(2): 141-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23622432

RESUMO

Variable-temperature Fourier transform infrared spectroscopy (FT-IR) and Raman spectroscopic mapping measurements were applied to study the phase separation of a poly(3-hydroxybutyrate) (PHB)-poly(L-lactic acid) (PLA) (50 : 50 wt.%) polymer-blend film as a function of temperature between 25 and 175 °C. Because of the better band separation compared with the fundamental absorptions, the first overtones of the ν(C=O) bands of PHB and PLA were used to evaluate the temperature-dependent FT-IR images as PLA-PHB and PHB-PLA band-ratio contour plots, respectively. From the visualization of the band-ratio FT-IR images, it could be derived that even beyond the melting point of PLA (145 °C), the lateral position and the geometry of the PHB-rich and PLA-rich phases were retained up to 165 °C. Furthermore, the FT-IR images derived during and after the melting of PHB (174 °C) provided an interesting insight into the homogenization process of the polymer melt. By exploiting its higher lateral resolution, valuable additional information became available from the Raman mapping measurements. Based on the Raman data, the scenario of phase-separated PHB-rich and PLA-rich domains of about 50 µm size, based on the FT-IR imaging measurements, had to be revised. Instead, the originally interpreted PHB-rich and PLA-rich domains are actually clusters of much smaller grains. Additionally, the Raman images measured in the same temperature interval revealed that the clusters of small PHB-rich grain structures aggregated as a function of temperature increase. These investigations prove that FT-IR and Raman imaging in combination with variable-temperature measurements can provide new (and so far unavailable) insights into structural phenomena of phase-separated polymer blends.

17.
Appl Spectrosc ; 66(10): 1145-55, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23031697

RESUMO

A library of poly(2-oxazoline)s with varying length of the alkyl side-chain has been investigated by variable-temperature Fourier transform infrared (FT-IR) spectroscopy. These polymers are suitable for studies of structure-property relationships as their cationic ring-opening polymerization and the relatively facile monomer synthesis enable a control of the molecular structure. In this contribution, the number of carbon atoms in the linear side-chain is systematically varied from a short methyl to a long nonyl group. Previous studies showed that the sample library can be split in two groups: poly(2-oxazoline)s with a short side-chain (methyl-, ethyl-, and isopropyl-) exhibit hygroscopic behavior, while those with longer side-groups (butyl- and longer) were found to be semi-crystalline. To gain further insight into the mechanisms of hydrogen bonding and crystallization, temperature-dependent infrared (IR) spectroscopy has been applied in the current study. The processes involved have been monitored by generalized two-dimensional correlation spectroscopy (2DCOS) and perturbation-correlation moving-window two-dimensional correlation spectroscopy (PCMW2D) in the C=O stretching region around 1645 cm(-1). These advanced analysis techniques provided valuable additional information on the material behavior during heating. As water is removed from the samples in the course of the heating process, it was possible to clearly distinguish between "loosely associated" and hydrogen-bonded water. Furthermore, the melting process of the semi-crystalline samples could be depicted. For the poly(2-isopropyl-2-oxazoline) even a crystallization process could be monitored in the temperature range between glass transition and melting.

18.
Anal Chem ; 84(19): 8330-9, 2012 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-22924791

RESUMO

A sequential identification approach by two-dimensional (2D) correlation analysis for the identification of a chemical reaction model, activation, and thermodynamic parameters is presented in this paper. The identification task is decomposed into a sequence of subproblems. The first step is the construction of a reaction model with the suggested information by model-free 2D correlation analysis using a novel technique called derivative double 2D correlation spectroscopy (DD2DCOS), which enables one to analyze intensities with nonlinear behavior and overlapped bands. The second step is a model-based 2D correlation analysis where the activation and thermodynamic parameters are estimated by an indirect implicit calibration or a calibration-free approach. In this way, a minimization process for the spectral information by sample-sample 2D correlation spectroscopy and kinetic hard modeling (using ordinary differential equations) of the chemical reaction model is carried out. The sequential identification by 2D correlation analysis is illustrated with reference to the isomeric structure of diphenylurethane synthesized from phenylisocyanate and phenol. The reaction was investigated by FT-IR spectroscopy. The activation and thermodynamic parameters of the isomeric structures of diphenylurethane linked through a hydrogen bonding equilibrium were studied by means of an integration of model-free and model-based 2D correlation analysis called a sequential identification approach. The study determined the enthalpy (ΔH = 15.25 kJ/mol) and entropy (TΔS = 13.20 kJ/mol) of C═O···H hydrogen bonding of diphenylurethane through direct calculation from the differences in the kinetic parameters (δΔ(‡)H, -TδΔ(‡)S) at equilibrium in the chemical reaction system.


Assuntos
Modelos Químicos , Fenilcarbamatos/química , Termodinâmica , Uretana/química , Calibragem , Ligação de Hidrogênio , Estrutura Molecular , Fenilcarbamatos/síntese química , Espectroscopia de Infravermelho com Transformada de Fourier , Estereoisomerismo , Uretana/síntese química
19.
J Phys Chem A ; 116(30): 7797-808, 2012 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-22734633

RESUMO

The doublet of the ν(C=O) carbonyl band in isomeric urethane systems has been extensively discussed in qualitative terms on the basis of FT-IR spectroscopy of the macromolecular structures. Recently, a reaction extent model was proposed as an inverse kinetic problem for the synthesis of diphenylurethane for which hydrogen-bonded and non-hydrogen-bonded C=O functionalities were identified. In this article, the heteronuclear C=O···H-N hydrogen bonding in the isomeric structure of diphenylurethane synthesized from phenylisocyanate and phenol was investigated via FT-IR spectroscopy, using a methodology of regularization for the inverse reaction extent model through an eigenvalue problem. The kinetic and thermodynamic parameters of this system were derived directly from the spectroscopic data. The activation and thermodynamic parameters of the isomeric structures of diphenylurethane linked through a hydrogen bonding equilibrium were studied. The study determined the enthalpy (ΔH = 15.25 kJ/mol), entropy (TΔS = 14.61 kJ/mol), and free energy (ΔG = 0.6 kJ/mol) of heteronuclear C=O···H-N hydrogen bonding by FT-IR spectroscopy through direct calculation from the differences in the kinetic parameters (δΔ(‡)H, -TδΔ(‡)S, and δΔ(‡)G) at equilibrium in the chemical reaction system. The parameters obtained in this study may contribute toward a better understanding of the properties of, and interactions in, supramolecular systems, such as the switching behavior of hydrogen bonding.

20.
Appl Spectrosc ; 65(9): 1051-5, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21929860

RESUMO

Time-resolved Fourier transform near-infrared (FT-NIR) spectroscopic imaging was applied to the diffusion process of butanol(OD) into polyamide 11 (PA11) with a novel sheet-structured variable-temperature-controlled sample holder in order to demonstrate the significant differences of diffusion rate below and above the glass transition temperature of PA11. The diffusant butanol(OD) was chosen for two reasons: (1) it allows the diffusion front to be monitored by the intensity decrease of a NH-specific absorption band of PA11 due to the NH/ND isotope exchange and (2) under the measurement conditions the diffusion of butanol(OD) into PA11 takes place in an experimentally manageable time frame. Apart from the in situ visualization of the diffusion front in the time-resolved FT-NIR images, the type of diffusion and the diffusion coefficient of butanol(OD) into PA11 have been determined.


Assuntos
Butanóis/química , Nylons/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Difusão , Modelos Lineares , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...