Opt Express ; 21(22): 25677-84, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24216793

RESUMO

We have carried out grating-based x-ray differential phase-contrast measurements with a hybrid pixel detector in 16 energy channels simultaneously. A method for combining the energy resolved phase-contrast images based on energy weighting is presented. An improvement in contrast-to-noise ratio by 58.2% with respect to an emulated integrating detector could be observed in the final image. The same image quality could thus be achieved with this detector and with energy weighting at 60.0% reduced dose compared to an integrating detector. The benefit of the method depends on the object, spectrum, interferometer design and the detector efficiency.


Assuntos
Fotometria/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Refratometria/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
2.
Phys Med Biol ; 58(8): 2713-32, 2013 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-23552903

RESUMO

We show that a distribution of micrometer-sized calcifications in the human breast which are not visible in clinical x-ray mammography at diagnostic dose levels can produce a significant dark-field signal in a grating-based x-ray phase-contrast imaging setup with a tungsten anode x-ray tube operated at 40 kVp. A breast specimen with invasive ductal carcinoma was investigated immediately after surgery by Talbot-Lau x-ray interferometry with a design energy of 25 keV. The sample contained two tumors which were visible in ultrasound and contrast-agent enhanced MRI but invisible in clinical x-ray mammography, in specimen radiography and in the attenuation images obtained with the Talbot-Lau interferometer. One of the tumors produced significant dark-field contrast with an exposure of 0.85 mGy air-kerma. Staining of histological slices revealed sparsely distributed grains of calcium phosphate with sizes varying between 1 and 40 µm in the region of this tumor. By combining the histological investigations with an x-ray wave-field simulation we demonstrate that a corresponding distribution of grains of calcium phosphate in the form of hydroxylapatite has the ability to produce a dark-field signal which would-to a substantial degree-explain the measured dark-field image. Thus we have found the appearance of new information (compared to attenuation and differential phase images) in the dark-field image. The second tumor in the same sample did not contain a significant fraction of these very fine calcification grains and was invisible in the dark-field image. We conclude that some tumors which are invisible in x-ray absorption mammography might be detected in the x-ray dark-field image at tolerable dose levels.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Calcinose/patologia , Escuridão , Mamografia/métodos , Neoplasias da Mama/metabolismo , Calcinose/diagnóstico por imagem , Fosfatos de Cálcio/metabolismo , Feminino , Humanos , Interferometria , Pessoa de Meia-Idade