Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Diagn Interv Imaging ; 104(5): 235-242, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36646587

RESUMO

PURPOSE: The purpose of this study was to investigate the feasibility of identifying and characterizing the three most common types of endoleaks within a thoracic aorta aneurysm model using bicolor K-edge imaging with a spectral photon-counting computing tomography (SPCCT) system in combination with a biphasic contrast agent injection. MATERIALS AND METHODS: Three types of thoracic endoleaks (type 1, 2 and 3) were created in a dynamic anthropomorphic thoracic aorta phantom. Protocol consisted in an injection of an iodinated contrast material followed 80 seconds after an injection of a gadolinium-based contrast agent (GBCA). The phantom was scanned using a clinical prototype SPCCT during bicolor phase imaging consisting in an early distribution of GBCA and a late distribution of iodine. Conventional and spectral images were reconstructed for differentiating between the contrast agents and measuring their respective attenuation values and concentrations inside and outside the stent graft. RESULTS: Conventional images failed to provide specific dynamic imaging contrast agents in the aneurysmal sac and outside the stent graft while spectral images differentiated their specific distribution. In type 1 and 3 thoracic endoleaks, GBCA concentration was measured outside the stent graft at 6.1 ± 3.7 (standard deviation [SD]) mg/mL and 6.0 ± 4.0 (SD) mg/mL, respectively, in favor of an early blood flow. In type 2 thoracic endoleak, iodine was measured outside the stent graft at 24.3 ± 5.5 (SD) mg/mL in favor of a late blood flow in the aneurysmal sac. CONCLUSION: Bicolor K-edge imaging enabled SPCCT allows a bicolor characterization of thoracic aorta endoleaks in a single acquisition in combination with a biphasic contrast agent injection.


Assuntos
Meios de Contraste , Iodo , Humanos , Endoleak/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
2.
Front Cardiovasc Med ; 9: 873144, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35694668

RESUMO

Objective: The standard treatment for complicated Stanford type B aortic dissection (TBAD) is thoracic endovascular aortic repair (TEVAR). Functional parameters, specifically blood flow, are not measured in the clinical assessment of TEVAR, yet they are of outmost importance in patient outcome. Consequently, we investigated the impact of TEVAR on the flows in the aorta and its branches in TBAD using 4D Phase-Contrast Magnetic Resonance Imaging (4D Flow MRI). Methods: Seven patients with TBAD scheduled for TEVAR underwent pre and post-operative 4D Flow MRI. An experienced reader assessed the presence of helical flow in the false lumen (FL) using streamlines and measured net flow at specific locations. In addition, forward and reverse flows, stasis, helicity, and absolute helicity were computed automatically along the aorta centerline. Average values were then computed in the segmented vessels. Impact of TEVAR on these parameters was assessed with a Wilcoxon signed rank test. Impact of the metallic stent on the velocity quantification was assessed using intra-class correlation coefficient (ICC) between velocities measured intra-stent and in adjacent stent-free regions. Results: FL helical flow was observed proximally in 6 cases and distally in 2 cases pre-operatively. Helical flow disappeared post-TEVAR proximally, but developed distally for 2 patients. Intra-stent measures were similar to stent-free with a median difference of 0.1 L/min and an ICC equal to 0.967 (p < 0.01). Forward flow increased from 59.9 to 81.6% in the TL and significantly decreased in the FL from 15.9 to 3.3%. Similarly, reverse flow increased in the TL from 4.36 to 10.8% and decreased in the FL from 10.3 to 4.6%. No significant changes were observed in net flow for aortic branches (p > 0.05). A significant increase in FL stasis was observed (p = 0.04). Discussion: TEVAR significantly increased forward flow in the TL and significantly decreased both forward and reverse flows in the FL. Interestingly, reverse flow in the TL increased post-TEVAR, which could be due to increased rigidity of the wall, due to the metallic stent. User independent helicity quantification enabled detection of elevated helicity at the level of secondary entry tears which had been missed by streamline visualization.

3.
J Nucl Cardiol ; 29(3): 1064-1074, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33145738

RESUMO

BACKGROUND: Previous studies have suggested the role of microcalcifications in plaque vulnerability. This exploratory study sought to assess the potential of hybrid positron-emission tomography (PET)/magnetic resonance imaging (MRI) using 18F-sodium fluoride (18F-NaF) to check simultaneously 18F-NaF uptake, a marker of microcalcifications, and morphological criteria of vulnerability. METHODS AND RESULTS: We included 12 patients with either recently symptomatic or asymptomatic carotid stenosis. All patients underwent 18F-NaF PET/MRI. 18F-NaF target-to-background ratio (TBR) was measured in culprit and nonculprit (including contralateral plaques of symptomatic patients) plaques as well as in other arterial walls. Morphological criteria of vulnerability were assessed on MRI. Mineral metabolism markers were also collected. 18F-NaF uptake was higher in culprit compared to nonculprit plaques (median TBR 2.6 [2.2-2.8] vs 1.7 [1.3-2.2]; P = 0.03) but was not associated with morphological criteria of vulnerability on MRI. We found a positive correlation between 18F-NaF uptake and calcium plaque volume and ratio but not with circulating tissue-nonspecific alkaline phosphatase (TNAP) activity and inorganic pyrophosphate (PPi) levels. 18F-NaF uptake in the other arterial walls did not differ between symptomatic and asymptomatic patients. CONCLUSIONS: 18F-NaF PET/MRI may be a promising tool for providing additional insights into the plaque vulnerability.


Assuntos
Calcinose , Estenose das Carótidas , Placa Aterosclerótica , Calcinose/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Placa Aterosclerótica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio
4.
Invest Radiol ; 57(4): 212-221, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34711766

RESUMO

OBJECTIVES: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). MATERIALS AND METHODS: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. RESULTS: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. CONCLUSION: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada , Platina , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Humanos , Masculino , Imagens de Fantasmas , Fótons , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X/métodos
5.
Radiology ; 300(1): 98-107, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33944628

RESUMO

Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Modelos Animais de Doenças , Ouro , Macrófagos , Nanopartículas Metálicas , Fótons , Coelhos
6.
Diagn Interv Imaging ; 102(5): 305-312, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33610503

RESUMO

PURPOSE: The purpose of this study was to characterize the technical capabilities and feasibility of a large field-of-view clinical spectral photon-counting computed tomography (SPCCT) prototype for high-resolution (HR) lung imaging. MATERIALS AND METHODS: Measurement of modulation transfer function (MTF) and acquisition of a line pairs phantom were performed. An anthropomorphic lung nodule phantom was scanned with standard (120kVp, 62mAs), low (120kVp, 11mAs), and ultra-low (80kVp, 3mAs) radiation doses. A human volunteer underwent standard (120kVp, 63mAs) and low (120kVp, 11mAs) dose scans after approval by the ethics committee. HR images were reconstructed with 1024 matrix, 300mm field of view and 0.25mm slice thickness using a filtered-back projection (FBP) and two levels of iterative reconstruction (iDose 5 and 9). The conspicuity and sharpness of various lung structures (distal airways, vessels, fissures and proximal bronchial wall), image noise, and overall image quality were independently analyzed by three radiologists and compared to a previous HR lung CT examination of the same volunteer performed with a conventional CT equipped with energy integrating detectors (120kVp, 10mAs, FBP). RESULTS: Ten percent MTF was measured at 22.3lp/cm with a cut-off at 31lp/cm. Up to 28lp/cm were depicted. While mixed and solid nodules were easily depicted on standard and low-dose phantom images, higher iDose levels and slice thicknesses (1mm) were needed to visualize ground-glass components on ultra-low-dose images. Standard dose SPCCT images of in vivo lung structures were of greater conspicuity and sharpness, with greater overall image quality, and similar image noise (despite a flux reduction of 23%) to conventional CT images. Low-dose SPCCT images were of greater or similar conspicuity and sharpness, similar overall image quality, and lower but acceptable image noise (despite a flux reduction of 89%). CONCLUSIONS: A large field-of-view SPCCT prototype demonstrates HR technical capabilities and high image quality for high resolution lung CT in human.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Algoritmos , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
8.
Eur J Radiol ; 134: 109427, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33307461

RESUMO

PURPOSE: To evaluate the technical and diagnostic performance of three dimensional (3D) mDIXON versus 3D inversion recovery (3D VIAB) and 3D spectral presaturation with inversion recovery (3D SPIR) late gadolinium enhancement (LGE) sequences. METHODS: A total of 78 patients (50 males and 28 females, age 49 ± 18 years) with 1.5 T CMR examination including three different 3D LGE sequences (3D mDIXON, 3D VIAB, and 3D SPIR) were evaluated for technical and diagnostic performance by two readers. Qualitative scores and quantitative signal and contrast-to-noise ratios were compared among sequences. Qualitative comparisons were made using Friedman and Wilcoxon signed rank tests. Quantitative comparisons were made using one way ANOVA. Reader agreements were tested using Cohen's Kappa. Any p-value <0.05 was significant. RESULTS: 19 out of 78 patients (24 %) were excluded due to poor (grade 4) image quality and 29 patients were excluded due to absence of LGE. For the remaining 30 patients, free breathing 3D mDIXON showed higher confidence in diagnosis of subepicardial LGE (p-value < 0.05). 3D mDIXON outperformed 3D SPIR in both visualization of LGE (p = 0.02) and quality of fat suppression (p = 0.001). Nevertheless, 3D mDIXON showed lower image quality compared to the other two sequences. CONCLUSION: Free breathing 3D mDIXON is a diagnostic problem-solving tool, especially when making a diagnosis of subepicardial enhancement and/or fat suppression is needed, owing to its high spatial resolution and robust fat suppression. Choice of 3D LGE sequence should be based on patient's breath-hold ability, diagnostic needs, and institutional availability considering the strengths and limitations of each sequence.


Assuntos
Meios de Contraste , Gadolínio , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
10.
Comput Biol Med ; 118: 103644, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32174315

RESUMO

In the present study, we investigated the velocity profile over the carotid bifurcation in ten healthy volunteers by combining velocity measurements from two imaging modalities (PC-MRI and US-Doppler) and hemodynamic modeling in order to determine the optimal combination for the most realistic velocity estimation. The workflow includes data acquisition, velocity profile extraction at three sites (CCA, ECA and ICA), the arterial geometrical model reconstruction, a mesh generation and a rheological modeling. The results showed that US-Doppler measurements yielded higher velocity values as compared to PC-MRI (about 26% shift in CCA, 52% in ECA and 53% in ICA). This implies higher simulated velocities based on US-Doppler inlet as compared to simulated velocities based on PC-MRI inlet. Overall, PC-MRI inlet based simulations are closer to measurements than US-Doppler inlet based simulations. Moreover, the measured velocities showed that blood flow keeps a parabolic sectional profile distal from CCA, ECA and ICA, while being quite disturbed in the carotid sinus with a significant decrease in magnitude making this site very prone to atherosclerosis.


Assuntos
Artéria Carótida Primitiva , Hemodinâmica , Velocidade do Fluxo Sanguíneo , Artéria Carótida Primitiva/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Ultrassonografia
11.
Invest Radiol ; 55(2): 61-67, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31524765

RESUMO

OBJECTIVES: In-stent restenosis (ISR) is one of the main long-term complications after coronary stent placement, and the ability to evaluate ISR noninvasively using coronary computed tomography (CT) angiography remains challenging. For this application, spectral photon-counting CT (SPCCT) has the potential to increase image quality and reduce artifacts due to its advanced detector technology.Our study aimed to verify the technical and clinical potential of a novel SPCCT prototype using an ISR phantom setup. MATERIALS AND METHODS: Soft plaque-like restenosis (45 HU; approximately 50% of the stent lumen) were inserted into 10 different coronary stents (3 mm diameter), which were placed in a vessel phantom and filled with a contrast agent (400 HU). A research prototype SPCCT and a clinical dual-layer CT (DLCT; IQon; Philips) with comparable acquisition and reconstruction parameters were used to scan the phantoms. Conventional polyenergetic (PolyE) and monoenergetic (MonoE) images with 4 different energy levels (40, 60, 90, 120 keV) were reconstructed. Qualitative (delineation of the stenosis and adjacent residual lumen using a 5-point Likert scale) and quantitative (image noise, visible lumen diameter, lumen diameter adjacent to the stenosis, contrast-to-noise ratio of the restenosis) parameters were evaluated for both systems. RESULTS: The qualitative results averaged over all reconstructions were significantly superior for SPCCT compared with DLCT (eg, subjective rating of the best reconstruction of each scanner: DLCT PolyE: 2.80 ± 0.42 vs SPCCT MonoE 40 keV: 4.25 ± 1.03). Stenosis could be clearly detected in 9 and suspected in 10 of the 10 stents with both SPCCT and DLCT. The residual lumen next to the stenosis was clearly delineable in 7 of 10 stents (0.64 ± 0.11 mm or 34.97% of the measured stent lumen) with SPCCT, while it was not possible to delineate the residual lumen for all stents using DLCT. The measured diameter of the lumen within the stent was significantly higher for SPCCT compared with DLCT in all reconstructions with the best results for the MonoE 40 keV images (SPCCT: 1.80 ± 0.17 mm; DLCT: 1.50 ± 0.31 mm). The image noise and the contrast-to-noise ratio were better for DLCT than for SPCCT (contrast-to-noise ratio: DLCT MonoE 40: 31.58 ± 12.54; SPCCT MonoE 40: 4.64 ± 1.30). CONCLUSIONS: Spectral photon-counting CT allowed for the noninvasive evaluation of ISR with reliable results regarding the residual lumen for most tested stents and the clear identification or suspicion of stenosis for all stents. In contrast, the residual lumen could not be detected for a single stent using DLCT.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Stents , Artefatos , Técnicas In Vitro , Imagens de Fantasmas , Fótons
12.
Sci Rep ; 9(1): 19850, 2019 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-31882698

RESUMO

Correct visualization of the vascular lumen is impaired in standard computed tomography (CT) because of blooming artifacts, increase of apparent size, induced by metallic stents and vascular calcifications. Recently, due to the introduction of photon-counting detectors in the X-ray imaging field, a new prototype spectral photon-counting CT (SPCCT) based on a modified clinical CT system has been tested in a feasibility study for improving vascular lumen delineation and visualization of coronary stent architecture. Coronary stents of different metal composition were deployed inside plastic tubes containing hydroxyapatite spheres to simulate vascular calcifications and in the abdominal aorta of one New Zealand White (NZW) rabbit. Imaging was performed with an SPCCT prototype, a dual-energy CT system, and a conventional 64-channel CT system (B64). We found the apparent widths of the stents significantly smaller on SPCCT than on the other two systems in vitro (p < 0.01), thus closer to the true size. Consequently, the intra-stent lumen was significantly larger on SPCCT (p < 0.01). In conclusion, owing to the increased spatial resolution of SPCCT, improved lumen visualization and delineation of stent metallic mesh is possible compared to dual-energy and conventional CT.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Metais/química , Stents , Tomografia Computadorizada por Raios X/métodos , Animais , Artefatos , Estudos de Viabilidade , Humanos , Masculino , Coelhos , Reprodutibilidade dos Testes
13.
Sci Rep ; 9(1): 12090, 2019 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-31431689

RESUMO

Computed tomography (CT) is a widely used imaging modality. Among the recent technical improvements to increase the range of detection for optimized diagnostic, new devices such as dual energy CT allow elemental discrimination but still remain limited to two energies. Spectral photon-counting CT (SPCCT) is an emerging X-ray imaging technology with a completely new multiple energy detection and high spatial resolution (200 µm). This unique technique allows detection and quantification of a given element thanks to an element-specific increase in X-ray absorption for an energy (K-band) depending on its atomic number. The main contrast media used hitherto are iodine-based compounds but the K-edge of iodine (33.2 keV) is out of the range of detection. Therefore, it is crucial to develop contrast media suitable for this advanced technology. Gadolinium, well known and used element for MRI, possess a K-edge (50.2 keV) well suited for the SPCCT modality. The use of nano-objects instead of molecular entities is pushed by the necessity of high local concentration. In this work, nano-GdF3 is validated on a clinical based prototype, to be used as efficient in vivo contrast media. Beside an extremely high stability, it presents long lasting time in the blood pool allowing perfusion imaging of small animals, without apparent toxicity.


Assuntos
Meios de Contraste/farmacologia , Nanopartículas/química , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste/química , Fator 3 de Diferenciação de Crescimento/farmacologia , Humanos , Iodo/química , Iodo/farmacologia , Imageamento por Ressonância Magnética , Camundongos , Imagens de Fantasmas , Fótons/uso terapêutico
14.
Sci Rep ; 9(1): 8458, 2019 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-31186467

RESUMO

Diagnostic imaging of hepatocellular carcinoma (HCC) requires a liver CT or MRI multiphase acquisition protocol. Patients would benefit from a high-resolution imaging method capable of performing multi-phase imaging in a single acquisition without an increase in radiation dose. Spectral Photon-Counting Computed Tomography (SPCCT) has recently emerged as a novel and promising imaging modality in the field of diagnostic radiology. SPCCT is able to distinguish between two contrast agents referred to as multicolor imaging because, when measuring in three or more energy regimes, it can detect and quantify elements with a K-edge in the diagnostic energy range. Based on this capability, we tested the feasibility of a dual-contrast multi-phase liver imaging protocol via the use of iodinated and gadolinated contrast agents on four healthy New Zealand White (NZW) rabbits. To perform a dual-contrast protocol, we injected the agents at different times so that the first contrast agent visualized the portal phase and the second the arterial phase, both of which are mandatory for liver lesion characterization. We demonstrated a sensitive discrimination and quantification of gadolinium within the arteries and iodine within the liver parenchyma. In the hepatic artery, the concentration of gadolinium was much higher than iodine (8.5 ± 3.9 mg/mL versus 0.7 ± 0.1 mg/mL) contrary to the concentrations found in the liver parenchyma (0.5 ± 0.3 mg/mL versus 4.2 ± 0.3 mg/mL). In conclusion, our results confirm that SPCCT allows in-vivo dual contrast qualitative and quantitative multi-phase liver imaging in a single acquisition.


Assuntos
Abdome/diagnóstico por imagem , Absorciometria de Fóton , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Abdome/patologia , Animais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Meios de Contraste/farmacologia , Modelos Animais de Doenças , Gadolínio/farmacologia , Humanos , Iodo/farmacologia , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Fótons , Coelhos
15.
Eur Radiol Exp ; 2(1): 34, 2018 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-30327898

RESUMO

BACKGROUND: To evaluate the feasibility of multicolour quantitative imaging with spectral photon-counting computed tomography (SPCCT) of different mixed contrast agents. METHODS: Phantoms containing eleven tubes with mixtures of varying proportions of two contrast agents (i.e. two selected from gadolinium, iodine or gold nanoparticles) were prepared so that the attenuation of each tube was about 280 HU. Scans were acquired at 120 kVp and 100 mAs using a five-bin preclinical SPCCT prototype, generating conventional, water, iodine, gadolinium and gold images. The correlation between prepared and measured concentrations was assessed using linear regression. The cross-contamination was measured for each material as the root mean square error (RMSE) of its concentration in the other material images, where no signal was expected. The contrast-to-noise ratio (CNR) relative to a phosphate buffered saline tube was calculated for each contrast agent. RESULTS: The solutions had similar attenuations (279 ± 10 HU, mean ± standard deviation) and could not be differentiated on conventional images. However, a distinction was observed in the material images within the same samples, and the measured and prepared concentrations were strongly correlated (R2 ≥ 0.97, 0.81 ≤ slope ≤ 0.95, -0.68 ≤ offset ≤ 0.89 mg/mL). Cross-contamination in the iodine images for the mixture of gold and gadolinium contrast agents (RMSE = 0.34 mg/mL) was observed. CNR for 1 mg/mL of contrast agent was better for the mixture of iodine and gadolinium (CNRiodine = 3.20, CNRgadolinium = 2.80) than gold and gadolinium (CNRgadolinium = 1.67, CNRgold = 1.37). CONCLUSIONS: SPCCT enables multicolour quantitative imaging. As a result, it should be possible to perform imaging of multiple uptake phases of a given tissue/organ within a single scan by injecting different contrast agents sequentially.

16.
Eur Radiol ; 28(8): 3355-3361, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29468341

RESUMO

OBJECTIVES: Endovascular renal denervation (RDN) using catheter-based radiofrequency (RF) ablation has emerged as a potential treatment option for drug-resistant hypertension. Its efficacy is currently under debate. We aimed to evaluate the capability of contrast-enhanced magnetic resonance imaging (MRI) to assess the effects of RDN on the renal arterial wall in patients presenting with drug-resistant hypertension. METHODS: Patients were included prospectively following institutional review board approval and written informed consent. Renal arteries were imaged using a two-dimensional T1-weighted TSE sequence pre- and post-administration of a gadolinium-based contrast agent, before (D0), 2 days (D2) and 6 months (M6) after RDN. Mean enhancement of the wall (mENH) and mean wall thickness (mWT) were compared across time using an ANOVA with repeated measures and post-hoc paired t-test. RESULTS: Follow-up was completed for 23 patients (median age, 57 years; 16 men). The mENH at D2 (96.3 ± 36.0 %) was significantly higher than at D0 (61.1 ± 26.3%, p < 0.001) and M6 (66.1±22.7%, p < 0.001). Similarly, mWT was significantly higher at D2 (3.1 ± 0.4 m) than at D0 (2.7 ± 0.4mm, p < 0.001) and M6 (2.9 ± 0. 5 mm, p = 0.002). CONCLUSIONS: MRI demonstrated abnormalities of the arterial wall 2 days after RDN that had resolved at 6 months. KEY POINTS: • Contrast-enhanced MRI provides anatomic evidence of renal artery RF ablation • Temperature increase related to RF ablation induces transient arterial wall inflammation • Morphological effects observed 2 days post RF ablation are not visible after 6 months.


Assuntos
Ablação por Cateter/efeitos adversos , Hipertensão/cirurgia , Complicações Intraoperatórias/diagnóstico , Artéria Renal/lesões , Simpatectomia/efeitos adversos , Idoso , Análise de Variância , Anti-Hipertensivos/uso terapêutico , Ablação por Cateter/métodos , Resistência a Medicamentos , Feminino , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Simpatectomia/métodos
17.
Cereb Cortex ; 28(5): 1673-1684, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28334293

RESUMO

Do mathematical symbols evoke spatial representations? Although behavioral studies have long demonstrated interactions between space and the processing of Arabic digits, how to interpret these results remains controversial. Here, we tested whether activity in regions supporting spatial processing contributes to the processing of symbols conveying fundamental arithmetic concepts-such as operation signs-even in the absence of associated digits. Using functional magnetic resonance imaging, we show that merely perceiving a "+" sign triggers activity in brain regions that support the orienting of spatial attention in adults. Activity in these regions was greater for "+" than for "×" signs, indicating that it is modulated by whether an operator reflects an operation that evokes numerical manipulation (rather than rote memorization). Finally, the degree to which subjects activated a spatial region in response to a "+" sign was correlated with the degree to which subjects benefited from being briefly presented with that sign before having to calculate a single-digit addition problem, an effect termed operator-priming. Therefore, not only are some arithmetic operators linked to spatial intuitions, but such intuitions might also have an important role during arithmetic calculation. More generally, our findings support the view that mathematical symbols inherently evoke spatial representations.


Assuntos
Mapeamento Encefálico , Encéfalo/fisiologia , Matemática , Reconhecimento Visual de Modelos/fisiologia , Percepção Espacial/fisiologia , Adolescente , Adulto , Atenção/fisiologia , Encéfalo/diagnóstico por imagem , Feminino , Lateralidade Funcional , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Vias Neurais/diagnóstico por imagem , Vias Neurais/fisiologia , Oxigênio/sangue , Adulto Jovem
18.
Br J Radiol ; 91(1082): 20160919, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29125330

RESUMO

OBJECTIVE: To evaluate the accuracy of diffusion-weighted MRI with background suppression (DWIBS) in differentiating between malignant and benign mediastinal lymph-nodes. METHODS: Consecutive patients with enlarged mediastinal lymph-nodes underwent MRI DWIBS within 10 days prior to mediastinoscopy. Relative contrast ratios (RCRs) were computed on b800 and apparent diffusion coefficient (ADC) maps by dividing the node signal with the chest muscle signal, using manually drawn regions of interest (ROIs) by radiologists, blinded to pathology. Unpaired Student's t-tests were used to compare RCR-b800 and ADC between malignant and benign nodes. Receiver operating characteristic curves analyses were also performed. RESULTS: Six patients were excluded for poor image quality. Analysis was performed for 54 patients. Mean ADC values were significantly higher for benign (1740 ± 401 × 10-6 mm2 s-1) compared with malignant nodes (1266 ± 403 × 10-6 mm2 s-1, p = 0.0001). Mean RCR-b800 values were significantly lower for benign (2.64 ± 1.07) compared with malignant nodes (6.44 ± 3.47, p < 0.0001). Receiver operating characteristic analysis for RCR-b800 (cut-off of 3.6), showed a sensitivity of 90.9%, a specificity 83% and an accuracy 85% for differentiating benign from malignant nodes. For ADC (cut-off of 1285), the sensitivity was 68.2%, the specificity 84.6% and the accuracy 80.4%. CONCLUSION: DWIBS can accurately differentiate malignant from benign states in enlarged mediastinal lymph-nodes and represents an alternative method in aetiological work-up of mediastinal lymphadenopathies. Advances in knowledge: DWIBS may represent a useful adjunctive imaging modality, particularly for diagnosis of benign mediastinal lymph node, and thus may reduce the frequency of futile mediastinoscopy, which remains an invasive procedure.


Assuntos
Imagem de Difusão por Ressonância Magnética , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Mediastinoscopia , Mediastino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
19.
Sci Rep ; 7(1): 4784, 2017 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-28684756

RESUMO

A new prototype spectral photon-counting computed tomography (SPCCT) based on a modified clinical CT system has been developed. SPCCT analysis of the energy composition of the transmitted x-ray spectrum potentially allows simultaneous dual contrast agent imaging, however, this has not yet been demonstrated with such a system. We investigated the feasibility of using this system to distinguish gold nanoparticles (AuNP) and an iodinated contrast agent. The contrast agents and calcium phosphate were imaged in phantoms. Conventional CT, gold K-edge, iodine and water images were produced and demonstrated accurate discrimination and quantification of gold and iodine concentrations in a phantom containing mixtures of the contrast agents. In vivo experiments were performed using New Zealand White rabbits at several times points after injections of AuNP and iodinated contrast agents. We found that the contrast material maps clearly differentiated the distributions of gold and iodine in the tissues allowing quantification of the contrast agents' concentrations, which matched their expected pharmacokinetics. Furthermore, rapid, repetitive scanning was done, which allowed measurement of contrast agent kinetics with high temporal resolution. In conclusion, a clinical scale, high count rate SPCCT system is able to discriminate gold and iodine contrast media in different organs in vivo.


Assuntos
Meios de Contraste/farmacocinética , Tomografia Computadorizada por Raios X/métodos , Animais , Fosfatos de Cálcio , Feminino , Ouro/farmacocinética , Iopamidol/análogos & derivados , Iopamidol/farmacocinética , Masculino , Nanopartículas Metálicas , Imagens de Fantasmas , Coelhos
20.
Nanoscale ; 9(46): 18246-18257, 2017 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-28726968

RESUMO

Spectral photon counting computed tomography (SPCCT) is an emerging medical imaging technology. SPCCT scanners record the energy of incident photons, which allows specific detection of contrast agents due to measurement of their characteristic X-ray attenuation profiles. This approach is known as K-edge imaging. Nanoparticles formed from elements such as gold, bismuth or ytterbium have been reported as potential contrast agents for SPCCT imaging. Furthermore, gold nanoparticles have many applications in medicine, such as adjuvants for radiotherapy and photothermal ablation. In particular, longitudinal imaging of the biodistribution of nanoparticles would be highly attractive for their clinical translation. We therefore studied the capabilities of a novel SPCCT scanner to quantify the biodistribution of gold nanoparticles in vivo. PEGylated gold nanoparticles were used. Phantom imaging showed that concentrations measured on gold images correlated well with known concentrations (slope = 0.94, intercept = 0.18, RMSE = 0.18, R2 = 0.99). The SPCCT system allowed repetitive and quick acquisitions in vivo, and follow-up of changes in the AuNP biodistribution over time. Measurements performed on gold images correlated with the inductively coupled plasma-optical emission spectrometry (ICP-OES) measurements in the organs of interest (slope = 0.77, intercept = 0.47, RMSE = 0.72, R2 = 0.93). TEM results were in agreement with the imaging and ICP-OES in that much higher concentrations of AuNPs were observed in the liver, spleen, bone marrow and lymph nodes (mainly in macrophages). In conclusion, we found that SPCCT can be used for repetitive and non-invasive determination of the biodistribution of gold nanoparticles in vivo.


Assuntos
Ouro , Nanopartículas Metálicas , Tomografia Computadorizada por Raios X , Animais , Fótons , Coelhos , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...